The magic happens on port 9001 SELECT MAX(ID) as LAST_EXPORT_ID,(SELECT ID FROM `tbl_defect_export` WHERE `export_file` = '48_1573611069280.xlsm') as IMPORT_ID FROM tbl_defect_export WHERE 1=1 and Ship_ID = 48 ORDER BY ID DESC [ RowDataPacket { LAST_EXPORT_ID: 214, IMPORT_ID: 203 } ] SELECT * FROM tbl_defect_export WHERE 1=1 and Ship_ID = 48 and export_file = '48_1573611069280.xlsm' ORDER BY ID DESC ----xlData===== [ { ID: 5415, 'UNIQUE ID': '25/10/2019 2:53:02 PM', 'Date Recorded': 2019-06-21T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Display for OWS Bilge Mon not clear when seen from front, however can be seen at certain angle', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Requires replacement, last changed on 29 dec 2018 , as per email correspondences , to be claimed under guarantee. ', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': 'STAI190136', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5428, 'UNIQUE ID': '25/10/2019 3:59:57 PM', 'Date Recorded': 2019-10-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Grey water discharge pump not taking suction.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.31', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump needs overhauling ( need to change mouth ring). Raised RO. Awaiting spares', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': 'STAI190222', 'Status Code': 'Waiting spare', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5431, 'UNIQUE ID': '24/10/2019 11:58:45 PM', 'Date Recorded': 2019-03-14T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'CCTV -CAMERA NO: 2 (FWD) NOT WORKING , CAMERA NO: 3 ( FUNNEL DECK ) -ERRATIC ', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'ISPS Related', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '7.6', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CMERA NO : 2 (FWD - WHILE SELECTING GIVING ERROR DISPLAY ( COMPOSITE NO SYNC ) , CAMERA NO : 3 ( FUNNEL DCK ) NOT WORKING WITH DIRECT SELECTION OF NO : 3 CAMERA .WORK IN PROGRESS . OFFICE ADVISE SOUGHT ', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5434, 'UNIQUE ID': '25/10/2019 3:17:08 PM', 'Date Recorded': 2019-07-18T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'APK WBT gauge showing erratic reading', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.8', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'During Ballast operation at US, observed that when the tank is empty, the gauge is showing ballast tank level at 0.90 mtrs. And when the ballasting of APK was being carried out, it was not corrosponding to the relevent change in sounding of the tank. Req raised .Awaiting spares', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': 'STAI190182', 'Status Code': 'Waiting spare', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5935, 'UNIQUE ID': '2019-08-11 09:37:39.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Mooring wires are covered with mud due to use in yard. Cleaning and greasing required.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related,External Factors', 'VIQ Ref Number': '9.17', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All mooring wires planned for greasing in this ballast passage.', 'Target Date': 2020-02-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5937, 'UNIQUE ID': '2019-08-11 09:46:40.999', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Various tank domes of WBT and COT has rust weep marks. Derusting and painting required.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '8.18', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'derusting planned in this ballast passage to US', 'Target Date': 2020-01-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5938, 'UNIQUE ID': '2019-08-11 10:25:48.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'All the PV valves inspection date stencil to change.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.21', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'stencilling to be done on all PV valve.', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'In progress', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5939, 'UNIQUE ID': '2019-08-11 10:29:34.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Outside pump room Stbd side air valve leaking, To be renewed.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.4', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'air manifold valve to be renewed.', 'Target Date': 2019-11-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5941, 'UNIQUE ID': '2019-08-11 10:45:11.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Fire line pipe in scrubber room, just above the main power panel vibrates a lot at higher RPM. More supports to be welded. ', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '11.5', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'fitting of extra supports on the pipeline planned', 'Target Date': 2019-11-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5944, 'UNIQUE ID': '2019-08-11 19:49:28.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'MSDS and PPE to place in BWTS room for neutralizing chemicals.', 'Equipment Categories': 'Cargo Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Inappropriate Procedure', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'To put MSDS AND PPE', 'Target Date': 2019-11-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5945, 'UNIQUE ID': '2019-11-08 19:51:48.999', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Various electrical insulation mat in E/R and emergency DG room are deteriorated or salt soaked. To be renewed.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Inappropriate Procedure', 'VIQ Ref Number': '11.11', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'TO REPLACE THE INSULATION MATS', 'Target Date': 2019-11-14T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'In progress', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5946, 'UNIQUE ID': '2019-11-08 20:02:45.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Zebra stripe sticker to put in the newly installed low head pipe in ER bottom platform', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'To put stripe stickers. ', 'Target Date': 2019-11-12T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5950, 'UNIQUE ID': '2019-11-08 20:13:51.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'ME LO auto filter shaft seal leaking. To be renewed', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Will be renewed in the first oppurtunity', 'Target Date': 2019-12-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5951, 'UNIQUE ID': '2019-08-11 20:17:42.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Economiser surrounding to clean and paint', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'To be painted. ', 'Target Date': 2019-12-08T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'In progress', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5365, 'UNIQUE ID': '24/10/2019 10:38:50 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Main deck port side,U - Clamps on hydraulic lines, FW lines and air lines found rusted.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related,External Factors', 'VIQ Ref Number': '11.5', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All rusts removed and painted.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5366, 'UNIQUE ID': '24/10/2019 10:41:44 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'SIP\'S around the accommodation not clearly marked.', 'Equipment Categories': 'Hull & Tanks', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'External Factors,Human Error', 'VIQ Ref Number': '11.6', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'SIP markings completed.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-01T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5367, 'UNIQUE ID': '24/10/2019 10:43:36 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'ME UNIT # 6 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Cable renewed.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5368, 'UNIQUE ID': '24/10/2019 10:46:03 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Mooring wires dry and rusty not greased using wire rope greaser.', 'Equipment Categories': 'Deck Mach.,Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related,Human Error', 'VIQ Ref Number': '9.17', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All mooring wires greasing carried out.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-22T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5369, 'UNIQUE ID': '24/10/2019 10:48:36 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Port MGPS CU-AL anode showing error.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Defective control PCB for CU and AL-Anode replaced with new spare Port MGPS is operational.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-22T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5370, 'UNIQUE ID': '24/10/2019 10:50:32 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Dead man alarm indication light in pump room entrance not operational.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.11', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Received spare. Modified the switch and fitted back. It is working now.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5371, 'UNIQUE ID': '24/10/2019 10:59:49 PM', 'Date Recorded': 2019-01-30T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Port Side ECDIS unit on Bridge Buzzer for alarm is not working.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '', 'Risk Value of Obs': '', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Replaced operation circuit for ECDIS 2 (part No. OPU CCK-976 (PC640,7PCRD1796B)). Buzzer working satisfactorily.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5372, 'UNIQUE ID': '24/10/2019 11:05:55 PM', 'Date Recorded': 2019-02-06T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main engine # 6 unit jacket water outlet temperature reading shows erratic', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Temperature sensor renewed and working satisfactory.', 'Target Date': 2019-02-06T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-06T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5373, 'UNIQUE ID': '24/10/2019 11:07:47 PM', 'Date Recorded': 2019-02-16T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Vacuum toilet system port side line in operational', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Vacuum toilet line - Port side blockage rectified by flushing with water and air', 'Target Date': 2019-02-16T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-16T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5374, 'UNIQUE ID': '24/10/2019 11:09:56 PM', 'Date Recorded': 2019-02-18T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Sewage overboard valve - minor leakage ( 2/3 drop/day) through the storm valve body at the Engine room bottom floor on port side', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Temporary measures have been taken with UW and normal steel putty and currently no sign of leakage. New valve has been ordered. In order to renew the valve plugging of Overboard line is required.Sewage overboard valve renewed at Singapore anchorage.', 'Target Date': 2019-05-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-21T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5375, 'UNIQUE ID': '24/10/2019 11:11:49 PM', 'Date Recorded': 2019-02-21T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main CSW pump no.1 - Discharge pressure gauge showing incorrect value', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Root valve for the pressure gauge renewed and line blown through - Gauge is operational.', 'Target Date': 2019-02-22T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-21T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5376, 'UNIQUE ID': '24/10/2019 11:38:34 PM', 'Date Recorded': 2019-03-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Fresh water generator 1- Ejector pump sea water suction valve not holding, unable to isolate the pump.', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'valve Renewed', 'Target Date': 2019-10-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5377, 'UNIQUE ID': '24/10/2019 11:42:28 PM', 'Date Recorded': 2019-03-02T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Citadel Iridium Phone displaying "SIM Card Blocked" and can\'t be used.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '7.6', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Troubleshooting carried out with the help of IT departments. Phone is operational now.', 'Target Date': 2019-03-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5378, 'UNIQUE ID': '24/10/2019 11:47:00 PM', 'Date Recorded': 2019-03-07T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'ME Jacket pre heater steam inlet pressure gauge needle found broken.', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure gauge renewed.', 'Target Date': 2019-03-07T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-08T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5379, 'UNIQUE ID': '24/10/2019 11:49:58 PM', 'Date Recorded': 2019-03-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'ME- Aft Aux. Blower cooling fan blades found damaged', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'ME- Aft Aux. Blower cooling fan renewed and tested.', 'Target Date': 2019-03-10T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5380, 'UNIQUE ID': '25/10/2019 8:39:58 AM', 'Date Recorded': 2019-03-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'TG condenser –Condensate water inlet to vapour chamber pressure gauge found faulty', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure gauge renewed.', 'Target Date': 2019-03-24T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-24T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5381, 'UNIQUE ID': '25/10/2019 8:54:11 AM', 'Date Recorded': 2019-03-26T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main Engine -Fuel oil Viscotherm is showing erratic reading.', 'Equipment Categories': 'Elect. Mach. & Equip.,ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Sensor received and changed. Showing viscosity correctly', 'Target Date': 2019-06-25T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5382, 'UNIQUE ID': '25/10/2019 8:56:53 AM', 'Date Recorded': 2019-03-27T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Auxiliary Engine - T/C Exhaust gas inlet temperature sensor -A found faulty', 'Equipment Categories': 'Aux. Engine,Elect. Mach. & Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Sensor renewed and is operational.', 'Target Date': 2019-03-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-27T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5383, 'UNIQUE ID': '25/10/2019 8:59:47 AM', 'Date Recorded': 2019-03-29T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'WBT 3 (P) and WBT 5 (P) gauges showing erratic reading', 'Equipment Categories': 'Hull & Tanks', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.8', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': '5P & 3P WBT sensor renewed.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-01T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5384, 'UNIQUE ID': '25/10/2019 9:01:57 AM', 'Date Recorded': 2019-04-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Port windlass brake cylinder top cover seal slightly leaking', 'Equipment Categories': 'Deck Mach.,Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Scraper ring, wear ring and rod seal renewed for top cover and tested - working satisfactory.', 'Target Date': 2019-04-02T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-01T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5385, 'UNIQUE ID': '25/10/2019 9:03:51 AM', 'Date Recorded': 2019-04-16T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Pump Room Blower Motor Low Insulation.', 'Equipment Categories': 'Deck Mach.,Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.38', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump Room fan motor inside the terminal box one wire connection to motor winding got grounded, same replaced with new wire and motor both bearing changed with new spare, blower is operational', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-24T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5386, 'UNIQUE ID': '25/10/2019 9:07:39 AM', 'Date Recorded': 2019-04-28T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Forward whistle horn , reported not working', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '', 'Risk Value of Obs': '', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Motor electrical connection disconnected to facilitate the repair work of the whistle. Complete unit removed from its place and taken to workshop. Dismantled the unit and found connecting rod bearing completely damaged. Same replaced with old', 'Target Date': 2019-04-29T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5387, 'UNIQUE ID': '25/10/2019 9:09:58 AM', 'Date Recorded': 2019-05-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'CONNING DISPLAY ,PROCESSOR FAN FAIL', 'Equipment Categories': 'Aux. Mach.,Nav & comm. equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.1', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'processor fan replaced by CODAR technician at Singapore', 'Target Date': 2019-08-01T00:00:00.000Z, 'PO Ref No.': 'STAI190081', 'Status Code': 'Completed', 'Date Completed': 2019-05-21T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5388, 'UNIQUE ID': '25/10/2019 8:16:31 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Aux Boiler F.O. pump supply Mechanical seal leaking', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Mechanical Seal changed , P/P tried out satisfactory', 'Target Date': 2019-08-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5389, 'UNIQUE ID': '25/10/2019 11:38:10 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Frequency controllers for MSW pumps #3 not working', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'FREQUENCY CONTROLLER FOR NO1 AND 2 ATTENDED ON 15/06/2019 AND NOW WORKING SATISFACTORY, As per office instructions Frequency controller not to be changed. Pump to', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5390, 'UNIQUE ID': '25/10/2019 11:41:49 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'VACUUMARATOR PUMP NO.1 END PLATE BADLY WORN OUT .', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump working satisfactory. Parts kept as spare. To be changed if issue arises', 'Target Date': 2019-08-25T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5391, 'UNIQUE ID': '25/10/2019 11:45:20 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'IGS ECR Main control valve leaking when IG is venting to atmosphere and main blower in use', 'Equipment Categories': 'Inert Gas', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Valve seat renewed. Tried out . No leakage observed', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': 'STAI 190078', 'Status Code': 'Completed', 'Date Completed': 2019-08-05T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5392, 'UNIQUE ID': '25/10/2019 11:48:09 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'GE fuel line Pr regulating v/v 9k leaking', 'Equipment Categories': 'Aux. Engine', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Confirmed the operation during LSMGO and HFO. Found not leaking. Holdingnow. Under observation. Vessel received spare. Kept standby', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': 'STAI190112', 'Status Code': 'Completed', 'Date Completed': 2019-08-20T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5393, 'UNIQUE ID': '25/10/2019 11:51:49 AM', 'Date Recorded': 2019-05-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Control air dryer #1 not working', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-05T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5394, 'UNIQUE ID': '25/10/2019 11:54:11 AM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'No 1 boiler burner platform has steam / leakage. Looks like same', 'Equipment Categories': 'Boiler', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'steam regulating valve. To be', 'Target Date': 2019-05-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-24T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5395, 'UNIQUE ID': '25/10/2019 11:56:47 AM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Air bottles auto drain valve is kept shut. Same to be opened and all the crew to be advised accordingly.', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'VALVES OPENED AND CREW ADVISED OF THE OPERATION', 'Target Date': 2019-05-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-22T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5396, 'UNIQUE ID': '25/10/2019 12:00:28 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Area below the blower in steering Gear room needs to be cleaned.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.29', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Area cleaned and painted', 'Target Date': 2019-07-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5397, 'UNIQUE ID': '25/10/2019 1:36:51 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'In steam line there is steam / water leak from dump bypass valve and air ejector steam inlet valve. To be rectified by closing main steam stop valve', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'gasket renewed', 'Target Date': 2019-07-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-30T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5398, 'UNIQUE ID': '25/10/2019 1:40:19 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Provision compressor low pressure gauge to renew', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure Gauge renewed', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-02T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5399, 'UNIQUE ID': '25/10/2019 1:44:14 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Port side bunker manifold pressure gauge to renew, as same showing wrong indication.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure Gauge renewed', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-30T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5400, 'UNIQUE ID': '25/10/2019 1:50:47 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'All 3 Aft winches gear case relief valve spring is missing. To replace.', 'Equipment Categories': 'Deck Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.14', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Springs replaced.', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-14T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5401, 'UNIQUE ID': '25/10/2019 1:56:01 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Stbd side pump room blower motor top cover is temporarily repaired by cold work. New cover to fabricate and fit.', 'Equipment Categories': 'Deck Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Top cover brought in E/R workshop and fabricated', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5402, 'UNIQUE ID': '25/10/2019 2:07:01 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'T/C air intake room cleaning required.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Human Error', 'VIQ Ref Number': '10.29', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Gratings removed, chipped and painted.', 'Target Date': 2019-07-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-20T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5403, 'UNIQUE ID': '25/10/2019 2:09:27 PM', 'Date Recorded': 2019-05-25T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'COPT#2 Oil caution remark from shore analysis', 'Equipment Categories': 'Cargo Mach.,Deck Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.7', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'COPT NO2 OIL SUMP, DRAINED CLEANED AND OIL RENEWED', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5404, 'UNIQUE ID': '25/10/2019 2:12:28 PM', 'Date Recorded': 2019-05-25T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Few buttons on MF/HF keypad not functioning . Also,few pins of flat cable connected to the Keypad PCB found damaged making the above mentioned keys inoperational.', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '4.21', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'MF/HF equipment flat cable renewed and tested the GMDSS found working satisfactory.', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': 'STAI195045', 'Status Code': 'Completed', 'Date Completed': 2019-07-18T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5405, 'UNIQUE ID': '25/10/2019 2:15:59 PM', 'Date Recorded': 2019-05-27T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Soot blower # 3 of LP side is stuck. Not operating', 'Equipment Categories': 'Boiler', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Soot Blower LP3 removed from place , soot blower was stuck badly, sealing air passage was choked completely, same made free and cleared. Soot blower fitted back in place and tried out , satisfactory', 'Target Date': 2019-06-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5406, 'UNIQUE ID': '25/10/2019 2:18:03 PM', 'Date Recorded': 2019-05-27T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment,Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Clutch lining of Vacuum pump of Emergency Fire Pump came off while trying out of the pump', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Emgcy. Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.41', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Clutch lining renewed with the spare recd , pump tried out, satisfactory', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5407, 'UNIQUE ID': '25/10/2019 2:21:26 PM', 'Date Recorded': 2019-05-29T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Vibscanner is not operational', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Received new vibscanner. ', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5408, 'UNIQUE ID': '25/10/2019 2:25:15 PM', 'Date Recorded': 2019-06-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Siren for wind Hi-Hi alarm not operational and only light is working.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received at Singapore on 31/08/2019. Wind Hi-Hi siren and light replaced. Working satsifactorily', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-02T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5409, 'UNIQUE ID': '25/10/2019 2:29:07 PM', 'Date Recorded': 2019-06-11T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment,Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The GMT time in the BilgeGuard is 11-12 minutes behind the actual GMT time', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CHANGED 15 PPM MONITOR. NOW DIFFERENCE IS 3 MINS', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5410, 'UNIQUE ID': '25/10/2019 2:32:38 PM', 'Date Recorded': 2019-06-11T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'One of the Personal Gas Meter MSA Altair 4X (Sr no. 06028737) Showing Error message on O2, CO & H2S sensor on starting the equipment', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.23', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Replaced with the new gas meter received under warranty at GOLA, US on 09th July 2019', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5411, 'UNIQUE ID': '25/10/2019 2:37:17 PM', 'Date Recorded': 2019-06-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The WBT gas detection system function giving Fault 19 and 17. and is inoperable. FAULT (19) - “No custom setup, using default setup” comes and later after 15-20 seconds the FAULT(17) – “Analyzing unit no answer” shows.', 'Equipment Categories': 'Critical Equip.,Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.22', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Makers technician attanded vessel at GOLA, US on 08th July 2019. Troubleshooting done, necessary spares changed by technician and reconfiguration done.', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-08T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5412, 'UNIQUE ID': '25/10/2019 2:40:16 PM', 'Date Recorded': 2019-06-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'UTI (Sr. No. G17710) showing error message on start up indicating ‘’No msg’’.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.12', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Tape was unwinded to check for any damage and found tape damage at 60cm mark. Continuity test was done for the UTI to confirm the tape error.As per message from office as vessel have total 4 UTIs, so this faulty UTI to be landed ashore at next', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5413, 'UNIQUE ID': '25/10/2019 2:42:33 PM', 'Date Recorded': 2019-06-16T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'WBT 1 (P) gauge showing erratic reading', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.8', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Renewed sensor on 02nd Oct 2019.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-02T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5414, 'UNIQUE ID': '25/10/2019 2:47:46 PM', 'Date Recorded': 2019-06-21T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The local touch panel of WHRS( EGB) does not operate with touch, however operational with mouse', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'The touch screen panel renewed', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-20T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5416, 'UNIQUE ID': '25/10/2019 2:56:36 PM', 'Date Recorded': 2019-06-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'HFO PFR P/P NO2 MAGNETIC COUPLING CASING HOLED', 'Equipment Categories': 'Purifier', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CHANGED CAN OF THE COUPLING', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5417, 'UNIQUE ID': '25/10/2019 2:59:03 PM', 'Date Recorded': 2019-06-29T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'KW not matching with KWh meter reading and which leads to high SFOC, diff in % utilization of AEs.Actually KWHR is not for present KW', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'RESET THE KWH METER. NOW SHOWING VALUES CORRECTLY', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5418, 'UNIQUE ID': '25/10/2019 3:06:56 PM', 'Date Recorded': 2019-07-06T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'M/E F.O. leak off alarm not coming in the AMS', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Changed the Net DI 16. found alarm stilll there. Then found that in the tag in the AMS the switch had shifted to Man. Changed back to Auto. It is working fine. Changed it back to old NET DI16. Still it is functional.', 'Target Date': 2019-09-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5419, 'UNIQUE ID': '25/10/2019 3:13:00 PM', 'Date Recorded': 2019-07-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'EGB exhasut gas outlet temperature probe giving wrong readings', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'needs replacement. Shall raise RO for same. Entered in DD defect list', 'Target Date': 2019-09-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5420, 'UNIQUE ID': '25/10/2019 3:24:54 PM', 'Date Recorded': 2019-07-23T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'UTI (Sr. No. G18578) Display becomes blurred everytime after 5-10 minutes of operation', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.12', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Interchanged with the Display unit of UTI G17710 which was to be landed ashore as per message from office. Now UTI G 18578 is in good working order', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5421, 'UNIQUE ID': '25/10/2019 3:35:14 PM', 'Date Recorded': 2019-07-23T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Work shop AC OCR under rated ,getting tripped', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5422, 'UNIQUE ID': '25/10/2019 3:37:27 PM', 'Date Recorded': 2019-07-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'STBD life boat control circuit switch damaged', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.29', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Requisition received at Singapore on 31/08/2019. Control circuit replaced. Working satisfactorily now.', 'Target Date': 2019-10-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5423, 'UNIQUE ID': '25/10/2019 3:42:18 PM', 'Date Recorded': 2019-07-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Two wire programmable TX defective', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5424, 'UNIQUE ID': '25/10/2019 3:48:02 PM', 'Date Recorded': 2019-07-25T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Scrubber p/p mech seal leaking', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.31', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Mechanical sal renewed. Pump tried out.', 'Target Date': 2019-08-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-08T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5425, 'UNIQUE ID': '25/10/2019 3:50:01 PM', 'Date Recorded': 2019-08-08T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Cover for General Alarm switch on Port/Stbd boat deck broken', 'Equipment Categories': 'Elect. Mach. & Equip.,LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5426, 'UNIQUE ID': '25/10/2019 3:52:18 PM', 'Date Recorded': 2019-08-11T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The battery for BilgeMon 488 for OWS showing voltage 0.330 V against the required value of 2.5', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CHANGED 15 PPM SENSOR WITH NEW', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5427, 'UNIQUE ID': '25/10/2019 3:57:52 PM', 'Date Recorded': 2019-08-16T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment,Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Fire and GS p/p 1 mech seal leaking', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.31', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump dismantled and overhauled, mech seal and bottom line brearing renewed', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-23T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5429, 'UNIQUE ID': '25/10/2019 4:23:34 PM', 'Date Recorded': 2019-07-18T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Stbd windlass Hydraulic brake Cylinder leaking from Cylinder top seal during anchoring operations', 'Equipment Categories': 'Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Road seal and scrapper ring renewed. Brake tried out and found satisfactory. No further leaks observed.', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5430, 'UNIQUE ID': '25/10/2019 4:26:54 PM', 'Date Recorded': 2019-07-20T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'IG 43 - deck isolation valave for the IG Line after the IG NRV was found to be leaking and not holding', 'Equipment Categories': 'Cargo Mach.,Inert Gas', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.25', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'IG 43 valve removed from location and found valve disc damaged. Valve disc was builded and put back in plce again. But still minor leak exist. RO raised for Valve disc and seat ring. Valve renewed.', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': 'STAI190182', 'Status Code': 'Completed', 'Date Completed': 2019-10-25T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5432, 'UNIQUE ID': '25/10/2019 12:03:13 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Aux Boiler Feed water pumps motor #1 and #3 cooling Fan damaged', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Received the spare and changed the cooling fan. ', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5433, 'UNIQUE ID': '25/10/2019 2:44:53 PM', 'Date Recorded': 2019-06-20T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Kyma Engine Analyser defective', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Changed the cable connecting to computer by Technician', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5435, 'UNIQUE ID': '24/10/2019 9:47:45 PM', 'Date Recorded': 2019-01-04T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Anemometer- Wind speed transmitter found not working', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '4.7', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Old repaired Anemometer transmitter installed. Tested and found operational.', 'Target Date': 2019-01-14T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-13T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5436, 'UNIQUE ID': '24/10/2019 9:52:15 PM', 'Date Recorded': 2019-01-11T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'FWD air horn non operational', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Air horn compressor and motor overhauled , fitted back and tried out, working satisfactory.', 'Target Date': 2019-01-18T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-18T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5437, 'UNIQUE ID': '24/10/2019 9:57:34 PM', 'Date Recorded': 2019-01-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'IG Fan drain line in 3rd deck platform found leaking due to crack in the pipeline.', 'Equipment Categories': 'Inert Gas', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'New pipe fabricated wid stainless steel pipe and flange . Pipe replaced with fabricated one and tested, found satisfactory.', 'Target Date': 2019-01-12T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5438, 'UNIQUE ID': '24/10/2019 9:59:53 PM', 'Date Recorded': 2019-01-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main engine unit no.4 cyl.jacket inlet pipe leaking from flange joint.', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Gasket replaced and boxed back with stainless steel bolts.', 'Target Date': 2019-01-16T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-16T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5439, 'UNIQUE ID': '24/10/2019 10:02:27 PM', 'Date Recorded': 2019-01-14T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Hydraulic oil leakage from FWD windlass (PORT) High/Low control lever (DIRECTIONAL CONTROL VALVE)', 'Equipment Categories': 'Deck Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Both seals and o rings changed for the Directional control valve andf tested, and found working satisfactory.', 'Target Date': 2019-01-18T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-18T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5440, 'UNIQUE ID': '24/10/2019 10:06:01 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'COPT # 2 Discharge line flange valve no.260 in pump room found traces of oil leakage.', 'Equipment Categories': 'Cargo Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.44', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Oil traces cleaned and flange tightened,no oil leakage', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5441, 'UNIQUE ID': '24/10/2019 10:11:45 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Stenciling of various remote sounding boxes for ballast tanks missing', 'Equipment Categories': 'Hull & Tanks', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'Human Error', 'VIQ Ref Number': '11.7', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Steciling carried out for all remote sounding boxes for ballast tanks', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5442, 'UNIQUE ID': '24/10/2019 10:14:28 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'One light in pump room 2nd deck not working.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.11', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Light renewed', 'Target Date': 2019-01-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5443, 'UNIQUE ID': '24/10/2019 10:17:16 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Pressure regulator in air line for sea chest testing not fitted', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related,Human Error', 'VIQ Ref Number': '6.4', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure regulator fitted in air line for sea chest testing.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5444, 'UNIQUE ID': '24/10/2019 10:19:29 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Windlass pinion bearing found not greased and grease point not clearly marked.', 'Equipment Categories': 'Deck Mach.,Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related,Human Error', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Windlass pinion bearing greasing carried out and grease point marked.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-06T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5445, 'UNIQUE ID': '24/10/2019 10:24:15 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Helicopter equipement CO2 extinguishers not as per requirement', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Human Error,Knowledge Based', 'VIQ Ref Number': '5.4', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CO2 extinguishers installed as per requirement.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5446, 'UNIQUE ID': '24/10/2019 10:26:52 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'ME UNIT # 3 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related,Inappropriate Procedure', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Cable renewed soon after receiving new cable.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5447, 'UNIQUE ID': '24/10/2019 10:29:52 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'EGB bellow between LP and HP evaporator had traces of leakage, to be checked , cleaned and painted.', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Bellow inspected, no leakes found.Bellow area cleaned and painted.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-17T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5940, 'UNIQUE ID': '2019-08-11 19:41:53.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Water cooler outside ECR not operational. Cooler Compressor not running.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Leak rectified and cooler put in use', 'Target Date': 2019-11-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5947, 'UNIQUE ID': '2019-11-08 19:58:10.999', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'T/C suction room door not easy to open. To ease up and grease.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'DOOR EASED UP. ', 'Target Date': 2019-11-08T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-06T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5948, 'UNIQUE ID': '2019-11-08 20:07:39.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Steering gear room door self-closing mechanism needs to adjust as door remains in open condition.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Inappropriate Procedure', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Door adjusted. ', 'Target Date': 2019-11-07T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5949, 'UNIQUE ID': '2019-08-11 20:09:57.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Chlorine dosing pump of STP was running but no liquid passing. To be purged and checked regularly.', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Checked and purged. ', 'Target Date': 2019-11-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-05T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { 'UNIQUE ID': 2019-11-08T10:42:57.000Z, 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Drain near both aft E/R blower are choked. To be cleared.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Structural Condn. / WT integrity ', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': 6.2, 'Risk Value of Obs': 'High', 'PSC Ref Number': 'Not Applicable', 'PSC MOU ID': 'Not Applicable', 'Action Taken or Required': 'Drain line opened up for both blowers and cleared. ', 'Target Date': 2019-12-05T00:00:00.000Z, 'Status Code': 'Completed', 'Date Completed': 2019-11-13T00:00:00.000Z, Drydock: 'No', 'Audit Type': 'Internal' }, { 'UNIQUE ID': 2019-03-11T07:06:56.000Z, 'Date Recorded': 2019-10-31T00:00:00.000Z, 'Type of Deficiency': 'Breakdown', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Fwd Air horn not working.', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '4.7.3', 'Risk Value of Obs': 'High', 'PSC Ref Number': 'Not Applicable', 'PSC MOU ID': 'Not Applicable', 'Action Taken or Required': 'Spares received and renewed. Fog horn assembled and now in use', 'Target Date': 2019-11-30T00:00:00.000Z, 'Status Code': 'Completed', 'Date Completed': 2019-11-11T00:00:00.000Z, Drydock: 'No', 'Audit Type': 'Internal' }, { 'UNIQUE ID': 2019-08-11T19:37:25.000Z, 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Left over pneumatic pipe of old BWTS system in steering gear room to remove', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': 10.32, 'Risk Value of Obs': 'Very High', 'PSC Ref Number': 'Not Applicable', 'PSC MOU ID': 'Not Applicable', 'Action Taken or Required': 'All old pneumatic pipes removed and terminated. ', 'Target Date': 2019-11-15T00:00:00.000Z, 'Status Code': 'Completed', 'Date Completed': 2019-11-10T00:00:00.000Z, Drydock: 'No', 'Audit Type': 'External' }, ... 2 more items ] updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-06-21', Defciency_Descp: 'Display for OWS Bilge Mon not clear when seen from front, however can be seen at certain angle', PO_Ref: 'STAI190136', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-10-30', Action_Taken: 'Requires replacement, last changed on 29 dec 2018 , as per email correspondences , to be claimed under guarantee. ', unique_id: '25/10/2019 2:53:02 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:53:02 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 4, Record_Date: '2019-10-10', Defciency_Descp: 'Grey water discharge pump not taking suction.', PO_Ref: 'STAI190222', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'Pump needs overhauling ( need to change mouth ring). Raised RO. Awaiting spares', unique_id: '25/10/2019 3:59:57 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:59:57 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 10, Status_ID: 2, Record_Date: '2019-03-14', Defciency_Descp: 'CCTV -CAMERA NO: 2 (FWD) NOT WORKING , CAMERA NO: 3 ( FUNNEL DECK ) -ERRATIC ', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'CMERA NO : 2 (FWD - WHILE SELECTING GIVING ERROR DISPLAY ( COMPOSITE NO SYNC ) , CAMERA NO : 3 ( FUNNEL DCK ) NOT WORKING WITH DIRECT SELECTION OF NO : 3 CAMERA .WORK IN PROGRESS . OFFICE ADVISE SOUGHT ', unique_id: '24/10/2019 11:58:45 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:58:45 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 4, Record_Date: '2019-07-18', Defciency_Descp: 'APK WBT gauge showing erratic reading', PO_Ref: 'STAI190182', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'During Ballast operation at US, observed that when the tank is empty, the gauge is showing ballast tank level at 0.90 mtrs. And when the ballasting of APK was being carried out, it was not corrosponding to the relevent change in sounding of the tank. Req raised .Awaiting spares', unique_id: '25/10/2019 3:17:08 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:17:08 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Mooring wires are covered with mud due to use in yard. Cleaning and greasing required.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-02-05', Action_Taken: 'All mooring wires planned for greasing in this ballast passage.', unique_id: '2019-08-11 09:37:39.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 09:37:39.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Various tank domes of WBT and COT has rust weep marks. Derusting and painting required.', PO_Ref: '', VIQ_Question_ID: 8586, VIQ_QuestionNo: '8.18', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-01-05', Action_Taken: 'derusting planned in this ballast passage to US', unique_id: '2019-08-11 09:46:40.999' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 09:46:40.999' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'All the PV valves inspection date stencil to change.', PO_Ref: '', VIQ_Question_ID: 8589, VIQ_QuestionNo: '8.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'stencilling to be done on all PV valve.', unique_id: '2019-08-11 10:25:48.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 10:25:48.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Outside pump room Stbd side air valve leaking, To be renewed.', PO_Ref: '', VIQ_Question_ID: 8423, VIQ_QuestionNo: '11.4', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'air manifold valve to be renewed.', unique_id: '2019-08-11 10:29:34.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 10:29:34.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Fire line pipe in scrubber room, just above the main power panel vibrates a lot at higher RPM. More supports to be welded. ', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'fitting of extra supports on the pipeline planned', unique_id: '2019-08-11 10:45:11.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 10:45:11.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'MSDS and PPE to place in BWTS room for neutralizing chemicals.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-15', Action_Taken: 'To put MSDS AND PPE', unique_id: '2019-08-11 19:49:28.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 19:49:28.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Various electrical insulation mat in E/R and emergency DG room are deteriorated or salt soaked. To be renewed.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-14', Action_Taken: 'TO REPLACE THE INSULATION MATS', unique_id: '2019-11-08 19:51:48.999' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 19:51:48.999' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Zebra stripe sticker to put in the newly installed low head pipe in ER bottom platform', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-12', Action_Taken: 'To put stripe stickers. ', unique_id: '2019-11-08 20:02:45.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 20:02:45.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'ME LO auto filter shaft seal leaking. To be renewed', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-20', Action_Taken: 'Will be renewed in the first oppurtunity', unique_id: '2019-11-08 20:13:51.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 20:13:51.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Economiser surrounding to clean and paint', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-08', Action_Taken: 'To be painted. ', unique_id: '2019-08-11 20:17:42.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 20:17:42.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Main deck port side,U - Clamps on hydraulic lines, FW lines and air lines found rusted.', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-26', Target_Date: '2019-04-28', Action_Taken: 'All rusts removed and painted.', unique_id: '24/10/2019 10:38:50 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:38:50 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'SIP\'S around the accommodation not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8425, VIQ_QuestionNo: '11.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-01', Target_Date: '2019-04-28', Action_Taken: 'SIP markings completed.', unique_id: '24/10/2019 10:41:44 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:41:44 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 6 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed.', unique_id: '24/10/2019 10:43:36 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:43:36 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Mooring wires dry and rusty not greased using wire rope greaser.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-22', Target_Date: '2019-04-28', Action_Taken: 'All mooring wires greasing carried out.', unique_id: '24/10/2019 10:46:03 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:46:03 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Port MGPS CU-AL anode showing error.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-22', Target_Date: '2019-04-28', Action_Taken: 'Defective control PCB for CU and AL-Anode replaced with new spare Port MGPS is operational.', unique_id: '24/10/2019 10:48:36 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:48:36 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Dead man alarm indication light in pump room entrance not operational.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-09', Target_Date: '2019-10-31', Action_Taken: 'Received spare. Modified the switch and fitted back. It is working now.', unique_id: '24/10/2019 10:50:32 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:50:32 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-30', Defciency_Descp: 'Port Side ECDIS unit on Bridge Buzzer for alarm is not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-31', Action_Taken: 'Replaced operation circuit for ECDIS 2 (part No. OPU CCK-976 (PC640,7PCRD1796B)). Buzzer working satisfactorily.', unique_id: '24/10/2019 10:59:49 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:59:49 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-06', Defciency_Descp: 'Main engine # 6 unit jacket water outlet temperature reading shows erratic', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-02-06', Action_Taken: 'Temperature sensor renewed and working satisfactory.', unique_id: '24/10/2019 11:05:55 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:05:55 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-16', Defciency_Descp: 'Vacuum toilet system port side line in operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-16', Target_Date: '2019-02-16', Action_Taken: 'Vacuum toilet line - Port side blockage rectified by flushing with water and air', unique_id: '24/10/2019 11:07:47 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:07:47 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-18', Defciency_Descp: 'Sewage overboard valve - minor leakage ( 2/3 drop/day) through the storm valve body at the Engine room bottom floor on port side', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-05-31', Action_Taken: 'Temporary measures have been taken with UW and normal steel putty and currently no sign of leakage. New valve has been ordered. In order to renew the valve plugging of Overboard line is required.Sewage overboard valve renewed at Singapore anchorage.', unique_id: '24/10/2019 11:09:56 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:09:56 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-21', Defciency_Descp: 'Main CSW pump no.1 - Discharge pressure gauge showing incorrect value', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-21', Target_Date: '2019-02-22', Action_Taken: 'Root valve for the pressure gauge renewed and line blown through - Gauge is operational.', unique_id: '24/10/2019 11:11:49 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:11:49 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-01', Defciency_Descp: 'Fresh water generator 1- Ejector pump sea water suction valve not holding, unable to isolate the pump.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-10-15', Action_Taken: 'valve Renewed', unique_id: '24/10/2019 11:38:34 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:38:34 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-02', Defciency_Descp: 'Citadel Iridium Phone displaying "SIM Card Blocked" and can\'t be used.', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-31', Target_Date: '2019-03-20', Action_Taken: 'Troubleshooting carried out with the help of IT departments. Phone is operational now.', unique_id: '24/10/2019 11:42:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:42:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-07', Defciency_Descp: 'ME Jacket pre heater steam inlet pressure gauge needle found broken.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-08', Target_Date: '2019-03-07', Action_Taken: 'Pressure gauge renewed.', unique_id: '24/10/2019 11:47:00 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:47:00 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-10', Defciency_Descp: 'ME- Aft Aux. Blower cooling fan blades found damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-03-10', Action_Taken: 'ME- Aft Aux. Blower cooling fan renewed and tested.', unique_id: '24/10/2019 11:49:58 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:49:58 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-24', Defciency_Descp: 'TG condenser –Condensate water inlet to vapour chamber pressure gauge found faulty', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-24', Target_Date: '2019-03-24', Action_Taken: 'Pressure gauge renewed.', unique_id: '25/10/2019 8:39:58 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:39:58 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-26', Defciency_Descp: 'Main Engine -Fuel oil Viscotherm is showing erratic reading.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-10', Target_Date: '2019-06-25', Action_Taken: 'Sensor received and changed. Showing viscosity correctly', unique_id: '25/10/2019 8:54:11 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:54:11 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-27', Defciency_Descp: 'Auxiliary Engine - T/C Exhaust gas inlet temperature sensor -A found faulty', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-27', Target_Date: '2019-03-28', Action_Taken: 'Sensor renewed and is operational.', unique_id: '25/10/2019 8:56:53 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:56:53 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-03-29', Defciency_Descp: 'WBT 3 (P) and WBT 5 (P) gauges showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-01', Target_Date: '2019-10-31', Action_Taken: '5P & 3P WBT sensor renewed.', unique_id: '25/10/2019 8:59:47 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:59:47 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-04-01', Defciency_Descp: 'Port windlass brake cylinder top cover seal slightly leaking', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-01', Target_Date: '2019-04-02', Action_Taken: 'Scraper ring, wear ring and rod seal renewed for top cover and tested - working satisfactory.', unique_id: '25/10/2019 9:01:57 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:01:57 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-04-16', Defciency_Descp: 'Pump Room Blower Motor Low Insulation.', PO_Ref: '', VIQ_Question_ID: 8498, VIQ_QuestionNo: '10.38', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-24', Target_Date: '2019-04-28', Action_Taken: 'Pump Room fan motor inside the terminal box one wire connection to motor winding got grounded, same replaced with new wire and motor both bearing changed with new spare, blower is operational', unique_id: '25/10/2019 9:03:51 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:03:51 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-04-28', Defciency_Descp: 'Forward whistle horn , reported not working', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-29', Target_Date: '2019-04-29', Action_Taken: 'Motor electrical connection disconnected to facilitate the repair work of the whistle. Complete unit removed from its place and taken to workshop. Dismantled the unit and found connecting rod bearing completely damaged. Same replaced with old', unique_id: '25/10/2019 9:07:39 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:07:39 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-01', Defciency_Descp: 'CONNING DISPLAY ,PROCESSOR FAN FAIL', PO_Ref: 'STAI190081', VIQ_Question_ID: 8420, VIQ_QuestionNo: '11.1', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-08-01', Action_Taken: 'processor fan replaced by CODAR technician at Singapore', unique_id: '25/10/2019 9:09:58 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:09:58 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler F.O. pump supply Mechanical seal leaking', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-31', Action_Taken: 'Mechanical Seal changed , P/P tried out satisfactory', unique_id: '25/10/2019 8:16:31 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:16:31 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Frequency controllers for MSW pumps #3 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-08-30', Action_Taken: 'FREQUENCY CONTROLLER FOR NO1 AND 2 ATTENDED ON 15/06/2019 AND NOW WORKING SATISFACTORY, As per office instructions Frequency controller not to be changed. Pump to', unique_id: '25/10/2019 11:38:10 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:38:10 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'VACUUMARATOR PUMP NO.1 END PLATE BADLY WORN OUT .', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-07', Target_Date: '2019-08-25', Action_Taken: 'Pump working satisfactory. Parts kept as spare. To be changed if issue arises', unique_id: '25/10/2019 11:41:49 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:41:49 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'IGS ECR Main control valve leaking when IG is venting to atmosphere and main blower in use', PO_Ref: 'STAI 190078', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-05', Target_Date: '2019-08-30', Action_Taken: 'Valve seat renewed. Tried out . No leakage observed', unique_id: '25/10/2019 11:45:20 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:45:20 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'GE fuel line Pr regulating v/v 9k leaking', PO_Ref: 'STAI190112', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-20', Target_Date: '2019-10-31', Action_Taken: 'Confirmed the operation during LSMGO and HFO. Found not leaking. Holdingnow. Under observation. Vessel received spare. Kept standby', unique_id: '25/10/2019 11:48:09 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:48:09 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-12', Defciency_Descp: 'Control air dryer #1 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-05', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 11:51:49 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:51:49 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'No 1 boiler burner platform has steam / leakage. Looks like same', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-24', Target_Date: '2019-05-31', Action_Taken: 'steam regulating valve. To be', unique_id: '25/10/2019 11:54:11 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:54:11 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Air bottles auto drain valve is kept shut. Same to be opened and all the crew to be advised accordingly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-22', Target_Date: '2019-05-28', Action_Taken: 'VALVES OPENED AND CREW ADVISED OF THE OPERATION', unique_id: '25/10/2019 11:56:47 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:56:47 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Area below the blower in steering Gear room needs to be cleaned.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-03', Target_Date: '2019-07-21', Action_Taken: 'Area cleaned and painted', unique_id: '25/10/2019 12:00:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 12:00:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'In steam line there is steam / water leak from dump bypass valve and air ejector steam inlet valve. To be rectified by closing main steam stop valve', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-07-21', Action_Taken: 'gasket renewed', unique_id: '25/10/2019 1:36:51 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:36:51 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Provision compressor low pressure gauge to renew', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-02', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:40:19 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:40:19 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Port side bunker manifold pressure gauge to renew, as same showing wrong indication.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:44:14 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:44:14 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'All 3 Aft winches gear case relief valve spring is missing. To replace.', PO_Ref: '', VIQ_Question_ID: 8403, VIQ_QuestionNo: '9.14', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-14', Target_Date: '2019-06-21', Action_Taken: 'Springs replaced.', unique_id: '25/10/2019 1:50:47 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:50:47 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Stbd side pump room blower motor top cover is temporarily repaired by cold work. New cover to fabricate and fit.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-06-21', Action_Taken: 'Top cover brought in E/R workshop and fabricated', unique_id: '25/10/2019 1:56:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:56:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'T/C air intake room cleaning required.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-20', Target_Date: '2019-07-21', Action_Taken: 'Gratings removed, chipped and painted.', unique_id: '25/10/2019 2:07:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:07:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'COPT#2 Oil caution remark from shore analysis', PO_Ref: '', VIQ_Question_ID: 8467, VIQ_QuestionNo: '10.7', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-12', Target_Date: '2019-06-21', Action_Taken: 'COPT NO2 OIL SUMP, DRAINED CLEANED AND OIL RENEWED', unique_id: '25/10/2019 2:09:27 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:09:27 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'Few buttons on MF/HF keypad not functioning . Also,few pins of flat cable connected to the Keypad PCB found damaged making the above mentioned keys inoperational.', PO_Ref: 'STAI195045', VIQ_Question_ID: 8340, VIQ_QuestionNo: '4.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-18', Target_Date: '2019-08-30', Action_Taken: 'MF/HF equipment flat cable renewed and tested the GMDSS found working satisfactory.', unique_id: '25/10/2019 2:12:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:12:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Soot blower # 3 of LP side is stuck. Not operating', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-29', Target_Date: '2019-06-30', Action_Taken: 'Soot Blower LP3 removed from place , soot blower was stuck badly, sealing air passage was choked completely, same made free and cleared. Soot blower fitted back in place and tried out , satisfactory', unique_id: '25/10/2019 2:15:59 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:15:59 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 13, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Clutch lining of Vacuum pump of Emergency Fire Pump came off while trying out of the pump', PO_Ref: '', VIQ_Question_ID: 8558, VIQ_QuestionNo: '5.41', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-30', Action_Taken: 'Clutch lining renewed with the spare recd , pump tried out, satisfactory', unique_id: '25/10/2019 2:18:03 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:18:03 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-29', Defciency_Descp: 'Vibscanner is not operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received new vibscanner. ', unique_id: '25/10/2019 2:21:26 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:21:26 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-01', Defciency_Descp: 'Siren for wind Hi-Hi alarm not operational and only light is working.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-02', Target_Date: '2019-10-31', Action_Taken: 'Spares received at Singapore on 31/08/2019. Wind Hi-Hi siren and light replaced. Working satsifactorily', unique_id: '25/10/2019 2:25:15 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:25:15 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'The GMT time in the BilgeGuard is 11-12 minutes behind the actual GMT time', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-30', Action_Taken: 'CHANGED 15 PPM MONITOR. NOW DIFFERENCE IS 3 MINS', unique_id: '25/10/2019 2:29:07 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:29:07 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'One of the Personal Gas Meter MSA Altair 4X (Sr no. 06028737) Showing Error message on O2, CO & H2S sensor on starting the equipment', PO_Ref: '', VIQ_Question_ID: 8540, VIQ_QuestionNo: '5.23', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-09', Target_Date: '2019-08-30', Action_Taken: 'Replaced with the new gas meter received under warranty at GOLA, US on 09th July 2019', unique_id: '25/10/2019 2:32:38 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:32:38 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'The WBT gas detection system function giving Fault 19 and 17. and is inoperable. FAULT (19) - “No custom setup, using default setup” comes and later after 15-20 seconds the FAULT(17) – “Analyzing unit no answer” shows.', PO_Ref: '', VIQ_Question_ID: 8539, VIQ_QuestionNo: '5.22', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-08', Target_Date: '2019-08-30', Action_Taken: 'Makers technician attanded vessel at GOLA, US on 08th July 2019. Troubleshooting done, necessary spares changed by technician and reconfiguration done.', unique_id: '25/10/2019 2:37:17 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:37:17 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'UTI (Sr. No. G17710) showing error message on start up indicating ‘’No msg’’.', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Tape was unwinded to check for any damage and found tape damage at 60cm mark. Continuity test was done for the UTI to confirm the tape error.As per message from office as vessel have total 4 UTIs, so this faulty UTI to be landed ashore at next', unique_id: '25/10/2019 2:40:16 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:40:16 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-16', Defciency_Descp: 'WBT 1 (P) gauge showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-02', Target_Date: '2019-10-31', Action_Taken: 'Renewed sensor on 02nd Oct 2019.', unique_id: '25/10/2019 2:42:33 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:42:33 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-21', Defciency_Descp: 'The local touch panel of WHRS( EGB) does not operate with touch, however operational with mouse', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-20', Target_Date: '2019-11-30', Action_Taken: 'The touch screen panel renewed', unique_id: '25/10/2019 2:47:46 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:47:46 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-24', Defciency_Descp: 'HFO PFR P/P NO2 MAGNETIC COUPLING CASING HOLED', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-10', Target_Date: '2019-10-31', Action_Taken: 'CHANGED CAN OF THE COUPLING', unique_id: '25/10/2019 2:56:36 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:56:36 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-29', Defciency_Descp: 'KW not matching with KWh meter reading and which leads to high SFOC, diff in % utilization of AEs.Actually KWHR is not for present KW', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-15', Target_Date: '2019-10-31', Action_Taken: 'RESET THE KWH METER. NOW SHOWING VALUES CORRECTLY', unique_id: '25/10/2019 2:59:03 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:59:03 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-06', Defciency_Descp: 'M/E F.O. leak off alarm not coming in the AMS', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-10', Target_Date: '2019-09-30', Action_Taken: 'Changed the Net DI 16. found alarm stilll there. Then found that in the tag in the AMS the switch had shifted to Man. Changed back to Auto. It is working fine. Changed it back to old NET DI16. Still it is functional.', unique_id: '25/10/2019 3:06:56 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:06:56 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-12', Defciency_Descp: 'EGB exhasut gas outlet temperature probe giving wrong readings', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-15', Target_Date: '2019-09-30', Action_Taken: 'needs replacement. Shall raise RO for same. Entered in DD defect list', unique_id: '25/10/2019 3:13:00 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:13:00 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'UTI (Sr. No. G18578) Display becomes blurred everytime after 5-10 minutes of operation', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Interchanged with the Display unit of UTI G17710 which was to be landed ashore as per message from office. Now UTI G 18578 is in good working order', unique_id: '25/10/2019 3:24:54 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:24:54 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'Work shop AC OCR under rated ,getting tripped', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-09', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:35:14 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:35:14 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'STBD life boat control circuit switch damaged', PO_Ref: '', VIQ_Question_ID: 8546, VIQ_QuestionNo: '5.29', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-15', Action_Taken: 'Requisition received at Singapore on 31/08/2019. Control circuit replaced. Working satisfactorily now.', unique_id: '25/10/2019 3:37:27 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:37:27 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'Two wire programmable TX defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-26', Target_Date: '2019-10-30', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:42:18 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:42:18 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-25', Defciency_Descp: 'Scrubber p/p mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-08', Target_Date: '2019-08-15', Action_Taken: 'Mechanical sal renewed. Pump tried out.', unique_id: '25/10/2019 3:48:02 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:48:02 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-08-08', Defciency_Descp: 'Cover for General Alarm switch on Port/Stbd boat deck broken', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-11', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:50:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:50:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-11', Defciency_Descp: 'The battery for BilgeMon 488 for OWS showing voltage 0.330 V against the required value of 2.5', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-31', Action_Taken: 'CHANGED 15 PPM SENSOR WITH NEW', unique_id: '25/10/2019 3:52:18 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:52:18 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-16', Defciency_Descp: 'Fire and GS p/p 1 mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-23', Target_Date: '2019-08-30', Action_Taken: 'Pump dismantled and overhauled, mech seal and bottom line brearing renewed', unique_id: '25/10/2019 3:57:52 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:57:52 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-07-18', Defciency_Descp: 'Stbd windlass Hydraulic brake Cylinder leaking from Cylinder top seal during anchoring operations', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-26', Target_Date: '2019-08-30', Action_Taken: 'Road seal and scrapper ring renewed. Brake tried out and found satisfactory. No further leaks observed.', unique_id: '25/10/2019 4:23:34 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 4:23:34 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-20', Defciency_Descp: 'IG 43 - deck isolation valave for the IG Line after the IG NRV was found to be leaking and not holding', PO_Ref: 'STAI190182', VIQ_Question_ID: 8593, VIQ_QuestionNo: '8.25', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-25', Target_Date: '2019-10-30', Action_Taken: 'IG 43 valve removed from location and found valve disc damaged. Valve disc was builded and put back in plce again. But still minor leak exist. RO raised for Valve disc and seat ring. Valve renewed.', unique_id: '25/10/2019 4:26:54 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 4:26:54 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler Feed water pumps motor #1 and #3 cooling Fan damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received the spare and changed the cooling fan. ', unique_id: '25/10/2019 12:03:13 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 12:03:13 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-20', Defciency_Descp: 'Kyma Engine Analyser defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-11-30', Action_Taken: 'Changed the cable connecting to computer by Technician', unique_id: '25/10/2019 2:44:53 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:44:53 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-04', Defciency_Descp: 'Anemometer- Wind speed transmitter found not working', PO_Ref: '', VIQ_Question_ID: 8326, VIQ_QuestionNo: '4.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-13', Target_Date: '2019-01-14', Action_Taken: 'Old repaired Anemometer transmitter installed. Tested and found operational.', unique_id: '24/10/2019 9:47:45 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:47:45 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-11', Defciency_Descp: 'FWD air horn non operational', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Air horn compressor and motor overhauled , fitted back and tried out, working satisfactory.', unique_id: '24/10/2019 9:52:15 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:52:15 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'IG Fan drain line in 3rd deck platform found leaking due to crack in the pipeline.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-12', Target_Date: '2019-01-12', Action_Taken: 'New pipe fabricated wid stainless steel pipe and flange . Pipe replaced with fabricated one and tested, found satisfactory.', unique_id: '24/10/2019 9:57:34 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:57:34 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'Main engine unit no.4 cyl.jacket inlet pipe leaking from flange joint.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-16', Target_Date: '2019-01-16', Action_Taken: 'Gasket replaced and boxed back with stainless steel bolts.', unique_id: '24/10/2019 9:59:53 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:59:53 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-14', Defciency_Descp: 'Hydraulic oil leakage from FWD windlass (PORT) High/Low control lever (DIRECTIONAL CONTROL VALVE)', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Both seals and o rings changed for the Directional control valve andf tested, and found working satisfactory.', unique_id: '24/10/2019 10:02:27 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:02:27 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'COPT # 2 Discharge line flange valve no.260 in pump room found traces of oil leakage.', PO_Ref: '', VIQ_Question_ID: 8615, VIQ_QuestionNo: '8.44', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-31', Target_Date: '2019-04-28', Action_Taken: 'Oil traces cleaned and flange tightened,no oil leakage', unique_id: '24/10/2019 10:06:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:06:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Stenciling of various remote sounding boxes for ballast tanks missing', PO_Ref: '', VIQ_Question_ID: 8426, VIQ_QuestionNo: '11.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-04-28', Action_Taken: 'Steciling carried out for all remote sounding boxes for ballast tanks', unique_id: '24/10/2019 10:11:45 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:11:45 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'One light in pump room 2nd deck not working.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-01-28', Action_Taken: 'Light renewed', unique_id: '24/10/2019 10:14:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:14:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Pressure regulator in air line for sea chest testing not fitted', PO_Ref: '', VIQ_Question_ID: 8351, VIQ_QuestionNo: '6.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-12', Target_Date: '2019-04-28', Action_Taken: 'Pressure regulator fitted in air line for sea chest testing.', unique_id: '24/10/2019 10:17:16 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:17:16 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Windlass pinion bearing found not greased and grease point not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-04-28', Action_Taken: 'Windlass pinion bearing greasing carried out and grease point marked.', unique_id: '24/10/2019 10:19:29 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:19:29 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Helicopter equipement CO2 extinguishers not as per requirement', PO_Ref: '', VIQ_Question_ID: 8520, VIQ_QuestionNo: '5.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-11', Target_Date: '2019-04-28', Action_Taken: 'CO2 extinguishers installed as per requirement.', unique_id: '24/10/2019 10:24:15 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:24:15 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 3 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-03', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed soon after receiving new cable.', unique_id: '24/10/2019 10:26:52 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:26:52 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'EGB bellow between LP and HP evaporator had traces of leakage, to be checked , cleaned and painted.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-17', Target_Date: '2019-04-28', Action_Taken: 'Bellow inspected, no leakes found.Bellow area cleaned and painted.', unique_id: '24/10/2019 10:29:52 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:29:52 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler outside ECR not operational. Cooler Compressor not running.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-09', Target_Date: '2019-11-15', Action_Taken: 'Leak rectified and cooler put in use', unique_id: '2019-08-11 19:41:53.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 19:41:53.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'T/C suction room door not easy to open. To ease up and grease.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-06', Target_Date: '2019-11-08', Action_Taken: 'DOOR EASED UP. ', unique_id: '2019-11-08 19:58:10.999' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 19:58:10.999' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Steering gear room door self-closing mechanism needs to adjust as door remains in open condition.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-07', Action_Taken: 'Door adjusted. ', unique_id: '2019-11-08 20:07:39.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 20:07:39.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Chlorine dosing pump of STP was running but no liquid passing. To be purged and checked regularly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-05', Target_Date: '2019-11-05', Action_Taken: 'Checked and purged. ', unique_id: '2019-08-11 20:09:57.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 20:09:57.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 16, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Drain near both aft E/R blower are choked. To be cleared.', PO_Ref: '', VIQ_Question_ID: 8349, VIQ_QuestionNo: 6.2, Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-13', Target_Date: '2019-12-05', Action_Taken: 'Drain line opened up for both blowers and cleared. ', unique_id: 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-10-31', Defciency_Descp: 'Fwd Air horn not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-11', Target_Date: '2019-11-30', Action_Taken: 'Spares received and renewed. Fog horn assembled and now in use', unique_id: 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Left over pneumatic pipe of old BWTS system in steering gear room to remove', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-10', Target_Date: '2019-11-15', Action_Taken: 'All old pneumatic pipes removed and terminated. ', unique_id: 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 4, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler in officer mess room was kept in isolated condition due to leak. TO be made operational.', PO_Ref: '', VIQ_Question_ID: 8432, VIQ_QuestionNo: 11.13, Risk_Value: 1, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-14', Target_Date: '2019-11-19', Action_Taken: 'Fountain tap leak was rectified. System back in operation. ', unique_id: 'Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Both boiler gauge glass light not working.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-15', Target_Date: '2019-11-15', Action_Taken: 'Light changed. ', unique_id: 'Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 resOfShip : ---- 25/10/2019 2:53:02 PM resOfShip : ---- 2019-08-11T09:43:02.000Z mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 4, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler in officer mess room was kept in isolated condition due to leak. TO be made operational.', PO_Ref: '', VIQ_Question_ID: 8432, VIQ_QuestionNo: 11.13, Risk_Value: 1, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-14', Target_Date: '2019-11-19', Action_Taken: 'Fountain tap leak was rectified. System back in operation. ', unique_id: 'Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Accommodation ', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:59:57 PM resOfShip : ---- 24/10/2019 11:58:45 PM resOfShip : ---- 25/10/2019 3:17:08 PM resOfShip : ---- 2019-08-11 09:37:39.000 resOfShip : ---- 2019-08-11 09:46:40.999 resOfShip : ---- 2019-08-11 10:25:48.000 resOfShip : ---- 2019-08-11 10:29:34.000 resOfShip : ---- 2019-08-11 10:45:11.000 resOfShip : ---- 2019-08-11 19:49:28.000 resOfShip : ---- 2019-11-08 19:51:48.999 resOfShip : ---- 2019-11-08 20:02:45.000 resOfShip : ---- 2019-11-08 20:13:51.000 resOfShip : ---- 2019-08-11 20:17:42.000 resOfShip : ---- 24/10/2019 10:38:50 PM resOfShip : ---- 24/10/2019 10:41:44 PM resOfShip : ---- 24/10/2019 10:43:36 PM resOfShip : ---- 24/10/2019 10:46:03 PM resOfShip : ---- 24/10/2019 10:48:36 PM resOfShip : ---- 24/10/2019 10:50:32 PM resOfShip : ---- 24/10/2019 10:59:49 PM resOfShip : ---- 24/10/2019 11:05:55 PM resOfShip : ---- 24/10/2019 11:07:47 PM resOfShip : ---- 24/10/2019 11:09:56 PM resOfShip : ---- 24/10/2019 11:11:49 PM resOfShip : ---- 24/10/2019 11:38:34 PM resOfShip : ---- 24/10/2019 11:42:28 PM resOfShip : ---- 24/10/2019 11:47:00 PM resOfShip : ---- 24/10/2019 11:49:58 PM resOfShip : ---- 25/10/2019 8:39:58 AM resOfShip : ---- 25/10/2019 8:54:11 AM resOfShip : ---- 25/10/2019 8:56:53 AM resOfShip : ---- 25/10/2019 8:59:47 AM resOfShip : ---- 25/10/2019 9:01:57 AM resOfShip : ---- 25/10/2019 9:03:51 AM resOfShip : ---- 25/10/2019 9:07:39 AM resOfShip : ---- 25/10/2019 9:09:58 AM resOfShip : ---- 25/10/2019 8:16:31 AM resOfShip : ---- 25/10/2019 11:38:10 AM resOfShip : ---- 25/10/2019 11:41:49 AM resOfShip : ---- 25/10/2019 11:45:20 AM resOfShip : ---- 25/10/2019 11:48:09 AM resOfShip : ---- 25/10/2019 11:51:49 AM resOfShip : ---- 25/10/2019 11:54:11 AM resOfShip : ---- 25/10/2019 11:56:47 AM resOfShip : ---- 25/10/2019 12:00:28 PM resOfShip : ---- 25/10/2019 1:36:51 PM resOfShip : ---- 25/10/2019 1:40:19 PM resOfShip : ---- 25/10/2019 1:44:14 PM resOfShip : ---- 25/10/2019 1:50:47 PM resOfShip : ---- 25/10/2019 1:56:01 PM resOfShip : ---- 25/10/2019 2:07:01 PM resOfShip : ---- 25/10/2019 2:09:27 PM resOfShip : ---- 25/10/2019 2:12:28 PM resOfShip : ---- 25/10/2019 2:15:59 PM resOfShip : ---- 25/10/2019 2:18:03 PM resOfShip : ---- 25/10/2019 2:21:26 PM resOfShip : ---- 25/10/2019 2:25:15 PM resOfShip : ---- 25/10/2019 2:29:07 PM resOfShip : ---- 25/10/2019 2:32:38 PM resOfShip : ---- 25/10/2019 2:37:17 PM resOfShip : ---- 25/10/2019 2:40:16 PM resOfShip : ---- 25/10/2019 2:42:33 PM resOfShip : ---- 25/10/2019 2:47:46 PM resOfShip : ---- 25/10/2019 2:56:36 PM resOfShip : ---- 25/10/2019 2:59:03 PM resOfShip : ---- 25/10/2019 3:06:56 PM resOfShip : ---- 25/10/2019 3:13:00 PM resOfShip : ---- 25/10/2019 3:24:54 PM resOfShip : ---- 25/10/2019 3:35:14 PM resOfShip : ---- 25/10/2019 3:37:27 PM resOfShip : ---- 25/10/2019 3:42:18 PM resOfShip : ---- 25/10/2019 3:48:02 PM resOfShip : ---- 25/10/2019 3:50:01 PM resOfShip : ---- 25/10/2019 3:52:18 PM resOfShip : ---- 25/10/2019 3:57:52 PM resOfShip : ---- 25/10/2019 4:23:34 PM resOfShip : ---- 25/10/2019 4:26:54 PM resOfShip : ---- 25/10/2019 12:03:13 AM resOfShip : ---- 25/10/2019 2:44:53 PM resOfShip : ---- 24/10/2019 9:47:45 PM resOfShip : ---- 24/10/2019 9:52:15 PM resOfShip : ---- 24/10/2019 9:57:34 PM resOfShip : ---- 24/10/2019 9:59:53 PM resOfShip : ---- 24/10/2019 10:02:27 PM resOfShip : ---- 24/10/2019 10:06:01 PM resOfShip : ---- 24/10/2019 10:11:45 PM resOfShip : ---- 24/10/2019 10:14:28 PM resOfShip : ---- 24/10/2019 10:17:16 PM resOfShip : ---- 24/10/2019 10:19:29 PM resOfShip : ---- 24/10/2019 10:24:15 PM resOfShip : ---- 24/10/2019 10:26:52 PM resOfShip : ---- 24/10/2019 10:29:52 PM resOfShip : ---- 2019-08-11 19:41:53.000 resOfShip : ---- 2019-11-08 19:58:10.999 resOfShip : ---- 2019-11-08 20:07:39.000 resOfShip : ---- 2019-08-11 20:09:57.000 resOfShip : ---- 2019-11-08T10:42:57.000Z mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 16, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Drain near both aft E/R blower are choked. To be cleared.', PO_Ref: '', VIQ_Question_ID: 8349, VIQ_QuestionNo: 6.2, Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-13', Target_Date: '2019-12-05', Action_Taken: 'Drain line opened up for both blowers and cleared. ', unique_id: 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'External Factors', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-03-11T07:06:56.000Z mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-10-31', Defciency_Descp: 'Fwd Air horn not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-11', Target_Date: '2019-11-30', Action_Taken: 'Spares received and renewed. Fog horn assembled and now in use', unique_id: 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Breakdown', Deficiency_Cause: 'Equipment Related', Equipments: 'Nav & comm. equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11T19:37:25.000Z mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Left over pneumatic pipe of old BWTS system in steering gear room to remove', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-10', Target_Date: '2019-11-15', Action_Taken: 'All old pneumatic pipes removed and terminated. ', unique_id: 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-11-08T19:44:49.998Z mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Both boiler gauge glass light not working.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-15', Target_Date: '2019-11-15', Action_Taken: 'Light changed. ', unique_id: 'Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Boiler', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-06-21', Defciency_Descp: 'Display for OWS Bilge Mon not clear when seen from front, however can be seen at certain angle', PO_Ref: 'STAI190136', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-10-30', Action_Taken: 'Requires replacement, last changed on 29 dec 2018 , as per email correspondences , to be claimed under guarantee. ', unique_id: '25/10/2019 2:53:02 PM' } OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34282, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 1 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34286, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 2 special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34290, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34294, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 4 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34298, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 5 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34303, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 6 deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 4, Record_Date: '2019-10-10', Defciency_Descp: 'Grey water discharge pump not taking suction.', PO_Ref: 'STAI190222', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'Pump needs overhauling ( need to change mouth ring). Raised RO. Awaiting spares', unique_id: '25/10/2019 3:59:57 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34307, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 10, Status_ID: 2, Record_Date: '2019-03-14', Defciency_Descp: 'CCTV -CAMERA NO: 2 (FWD) NOT WORKING , CAMERA NO: 3 ( FUNNEL DECK ) -ERRATIC ', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'CMERA NO : 2 (FWD - WHILE SELECTING GIVING ERROR DISPLAY ( COMPOSITE NO SYNC ) , CAMERA NO : 3 ( FUNNEL DCK ) NOT WORKING WITH DIRECT SELECTION OF NO : 3 CAMERA .WORK IN PROGRESS . OFFICE ADVISE SOUGHT ', unique_id: '24/10/2019 11:58:45 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34311, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 4, Record_Date: '2019-07-18', Defciency_Descp: 'APK WBT gauge showing erratic reading', PO_Ref: 'STAI190182', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'During Ballast operation at US, observed that when the tank is empty, the gauge is showing ballast tank level at 0.90 mtrs. And when the ballasting of APK was being carried out, it was not corrosponding to the relevent change in sounding of the tank. Req raised .Awaiting spares', unique_id: '25/10/2019 3:17:08 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34315, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Mooring wires are covered with mud due to use in yard. Cleaning and greasing required.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-02-05', Action_Taken: 'All mooring wires planned for greasing in this ballast passage.', unique_id: '2019-08-11 09:37:39.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34319, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Various tank domes of WBT and COT has rust weep marks. Derusting and painting required.', PO_Ref: '', VIQ_Question_ID: 8586, VIQ_QuestionNo: '8.18', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-01-05', Action_Taken: 'derusting planned in this ballast passage to US', unique_id: '2019-08-11 09:46:40.999' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34324, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'All the PV valves inspection date stencil to change.', PO_Ref: '', VIQ_Question_ID: 8589, VIQ_QuestionNo: '8.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'stencilling to be done on all PV valve.', unique_id: '2019-08-11 10:25:48.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34328, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Outside pump room Stbd side air valve leaking, To be renewed.', PO_Ref: '', VIQ_Question_ID: 8423, VIQ_QuestionNo: '11.4', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'air manifold valve to be renewed.', unique_id: '2019-08-11 10:29:34.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34332, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Fire line pipe in scrubber room, just above the main power panel vibrates a lot at higher RPM. More supports to be welded. ', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'fitting of extra supports on the pipeline planned', unique_id: '2019-08-11 10:45:11.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34336, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'MSDS and PPE to place in BWTS room for neutralizing chemicals.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-15', Action_Taken: 'To put MSDS AND PPE', unique_id: '2019-08-11 19:49:28.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34340, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Various electrical insulation mat in E/R and emergency DG room are deteriorated or salt soaked. To be renewed.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-14', Action_Taken: 'TO REPLACE THE INSULATION MATS', unique_id: '2019-11-08 19:51:48.999' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34344, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Zebra stripe sticker to put in the newly installed low head pipe in ER bottom platform', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-12', Action_Taken: 'To put stripe stickers. ', unique_id: '2019-11-08 20:02:45.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34348, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'ME LO auto filter shaft seal leaking. To be renewed', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-20', Action_Taken: 'Will be renewed in the first oppurtunity', unique_id: '2019-11-08 20:13:51.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34353, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Economiser surrounding to clean and paint', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-08', Action_Taken: 'To be painted. ', unique_id: '2019-08-11 20:17:42.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34357, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Main deck port side,U - Clamps on hydraulic lines, FW lines and air lines found rusted.', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-26', Target_Date: '2019-04-28', Action_Taken: 'All rusts removed and painted.', unique_id: '24/10/2019 10:38:50 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34361, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'SIP\'S around the accommodation not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8425, VIQ_QuestionNo: '11.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-01', Target_Date: '2019-04-28', Action_Taken: 'SIP markings completed.', unique_id: '24/10/2019 10:41:44 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34366, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 6 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed.', unique_id: '24/10/2019 10:43:36 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34371, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 6, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Mooring wires dry and rusty not greased using wire rope greaser.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-22', Target_Date: '2019-04-28', Action_Taken: 'All mooring wires greasing carried out.', unique_id: '24/10/2019 10:46:03 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 6, insertId: 34375, serverStatus: 2, warningCount: 3, message: '&Records: 6 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Port MGPS CU-AL anode showing error.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-22', Target_Date: '2019-04-28', Action_Taken: 'Defective control PCB for CU and AL-Anode replaced with new spare Port MGPS is operational.', unique_id: '24/10/2019 10:48:36 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34381, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Dead man alarm indication light in pump room entrance not operational.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-09', Target_Date: '2019-10-31', Action_Taken: 'Received spare. Modified the switch and fitted back. It is working now.', unique_id: '24/10/2019 10:50:32 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34385, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-30', Defciency_Descp: 'Port Side ECDIS unit on Bridge Buzzer for alarm is not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-31', Action_Taken: 'Replaced operation circuit for ECDIS 2 (part No. OPU CCK-976 (PC640,7PCRD1796B)). Buzzer working satisfactorily.', unique_id: '24/10/2019 10:59:49 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34389, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-06', Defciency_Descp: 'Main engine # 6 unit jacket water outlet temperature reading shows erratic', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-02-06', Action_Taken: 'Temperature sensor renewed and working satisfactory.', unique_id: '24/10/2019 11:05:55 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34393, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-16', Defciency_Descp: 'Vacuum toilet system port side line in operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-16', Target_Date: '2019-02-16', Action_Taken: 'Vacuum toilet line - Port side blockage rectified by flushing with water and air', unique_id: '24/10/2019 11:07:47 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34397, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-18', Defciency_Descp: 'Sewage overboard valve - minor leakage ( 2/3 drop/day) through the storm valve body at the Engine room bottom floor on port side', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-05-31', Action_Taken: 'Temporary measures have been taken with UW and normal steel putty and currently no sign of leakage. New valve has been ordered. In order to renew the valve plugging of Overboard line is required.Sewage overboard valve renewed at Singapore anchorage.', unique_id: '24/10/2019 11:09:56 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34401, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-21', Defciency_Descp: 'Main CSW pump no.1 - Discharge pressure gauge showing incorrect value', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-21', Target_Date: '2019-02-22', Action_Taken: 'Root valve for the pressure gauge renewed and line blown through - Gauge is operational.', unique_id: '24/10/2019 11:11:49 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34406, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-01', Defciency_Descp: 'Fresh water generator 1- Ejector pump sea water suction valve not holding, unable to isolate the pump.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-10-15', Action_Taken: 'valve Renewed', unique_id: '24/10/2019 11:38:34 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34411, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-02', Defciency_Descp: 'Citadel Iridium Phone displaying "SIM Card Blocked" and can\'t be used.', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-31', Target_Date: '2019-03-20', Action_Taken: 'Troubleshooting carried out with the help of IT departments. Phone is operational now.', unique_id: '24/10/2019 11:42:28 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34416, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-07', Defciency_Descp: 'ME Jacket pre heater steam inlet pressure gauge needle found broken.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-08', Target_Date: '2019-03-07', Action_Taken: 'Pressure gauge renewed.', unique_id: '24/10/2019 11:47:00 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34420, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-10', Defciency_Descp: 'ME- Aft Aux. Blower cooling fan blades found damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-03-10', Action_Taken: 'ME- Aft Aux. Blower cooling fan renewed and tested.', unique_id: '24/10/2019 11:49:58 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34425, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-24', Defciency_Descp: 'TG condenser –Condensate water inlet to vapour chamber pressure gauge found faulty', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-24', Target_Date: '2019-03-24', Action_Taken: 'Pressure gauge renewed.', unique_id: '25/10/2019 8:39:58 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34429, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 6, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-26', Defciency_Descp: 'Main Engine -Fuel oil Viscotherm is showing erratic reading.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-10', Target_Date: '2019-06-25', Action_Taken: 'Sensor received and changed. Showing viscosity correctly', unique_id: '25/10/2019 8:54:11 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 6, insertId: 34434, serverStatus: 2, warningCount: 3, message: '&Records: 6 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-27', Defciency_Descp: 'Auxiliary Engine - T/C Exhaust gas inlet temperature sensor -A found faulty', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-27', Target_Date: '2019-03-28', Action_Taken: 'Sensor renewed and is operational.', unique_id: '25/10/2019 8:56:53 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34440, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-03-29', Defciency_Descp: 'WBT 3 (P) and WBT 5 (P) gauges showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-01', Target_Date: '2019-10-31', Action_Taken: '5P & 3P WBT sensor renewed.', unique_id: '25/10/2019 8:59:47 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34445, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-04-01', Defciency_Descp: 'Port windlass brake cylinder top cover seal slightly leaking', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-01', Target_Date: '2019-04-02', Action_Taken: 'Scraper ring, wear ring and rod seal renewed for top cover and tested - working satisfactory.', unique_id: '25/10/2019 9:01:57 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34449, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-04-16', Defciency_Descp: 'Pump Room Blower Motor Low Insulation.', PO_Ref: '', VIQ_Question_ID: 8498, VIQ_QuestionNo: '10.38', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-24', Target_Date: '2019-04-28', Action_Taken: 'Pump Room fan motor inside the terminal box one wire connection to motor winding got grounded, same replaced with new wire and motor both bearing changed with new spare, blower is operational', unique_id: '25/10/2019 9:03:51 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34454, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-04-28', Defciency_Descp: 'Forward whistle horn , reported not working', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-29', Target_Date: '2019-04-29', Action_Taken: 'Motor electrical connection disconnected to facilitate the repair work of the whistle. Complete unit removed from its place and taken to workshop. Dismantled the unit and found connecting rod bearing completely damaged. Same replaced with old', unique_id: '25/10/2019 9:07:39 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34459, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-01', Defciency_Descp: 'CONNING DISPLAY ,PROCESSOR FAN FAIL', PO_Ref: 'STAI190081', VIQ_Question_ID: 8420, VIQ_QuestionNo: '11.1', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-08-01', Action_Taken: 'processor fan replaced by CODAR technician at Singapore', unique_id: '25/10/2019 9:09:58 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34463, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler F.O. pump supply Mechanical seal leaking', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-31', Action_Taken: 'Mechanical Seal changed , P/P tried out satisfactory', unique_id: '25/10/2019 8:16:31 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34468, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Frequency controllers for MSW pumps #3 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-08-30', Action_Taken: 'FREQUENCY CONTROLLER FOR NO1 AND 2 ATTENDED ON 15/06/2019 AND NOW WORKING SATISFACTORY, As per office instructions Frequency controller not to be changed. Pump to', unique_id: '25/10/2019 11:38:10 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34472, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'VACUUMARATOR PUMP NO.1 END PLATE BADLY WORN OUT .', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-07', Target_Date: '2019-08-25', Action_Taken: 'Pump working satisfactory. Parts kept as spare. To be changed if issue arises', unique_id: '25/10/2019 11:41:49 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34476, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'IGS ECR Main control valve leaking when IG is venting to atmosphere and main blower in use', PO_Ref: 'STAI 190078', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-05', Target_Date: '2019-08-30', Action_Taken: 'Valve seat renewed. Tried out . No leakage observed', unique_id: '25/10/2019 11:45:20 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34480, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'GE fuel line Pr regulating v/v 9k leaking', PO_Ref: 'STAI190112', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-20', Target_Date: '2019-10-31', Action_Taken: 'Confirmed the operation during LSMGO and HFO. Found not leaking. Holdingnow. Under observation. Vessel received spare. Kept standby', unique_id: '25/10/2019 11:48:09 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34484, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-12', Defciency_Descp: 'Control air dryer #1 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-05', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 11:51:49 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34488, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'No 1 boiler burner platform has steam / leakage. Looks like same', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-24', Target_Date: '2019-05-31', Action_Taken: 'steam regulating valve. To be', unique_id: '25/10/2019 11:54:11 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34492, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Air bottles auto drain valve is kept shut. Same to be opened and all the crew to be advised accordingly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-22', Target_Date: '2019-05-28', Action_Taken: 'VALVES OPENED AND CREW ADVISED OF THE OPERATION', unique_id: '25/10/2019 11:56:47 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34496, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Area below the blower in steering Gear room needs to be cleaned.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-03', Target_Date: '2019-07-21', Action_Taken: 'Area cleaned and painted', unique_id: '25/10/2019 12:00:28 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34500, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'In steam line there is steam / water leak from dump bypass valve and air ejector steam inlet valve. To be rectified by closing main steam stop valve', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-07-21', Action_Taken: 'gasket renewed', unique_id: '25/10/2019 1:36:51 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34504, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Provision compressor low pressure gauge to renew', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-02', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:40:19 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34509, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Port side bunker manifold pressure gauge to renew, as same showing wrong indication.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:44:14 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34513, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'All 3 Aft winches gear case relief valve spring is missing. To replace.', PO_Ref: '', VIQ_Question_ID: 8403, VIQ_QuestionNo: '9.14', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-14', Target_Date: '2019-06-21', Action_Taken: 'Springs replaced.', unique_id: '25/10/2019 1:50:47 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34517, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Stbd side pump room blower motor top cover is temporarily repaired by cold work. New cover to fabricate and fit.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-06-21', Action_Taken: 'Top cover brought in E/R workshop and fabricated', unique_id: '25/10/2019 1:56:01 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34521, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'T/C air intake room cleaning required.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-20', Target_Date: '2019-07-21', Action_Taken: 'Gratings removed, chipped and painted.', unique_id: '25/10/2019 2:07:01 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34525, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'COPT#2 Oil caution remark from shore analysis', PO_Ref: '', VIQ_Question_ID: 8467, VIQ_QuestionNo: '10.7', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-12', Target_Date: '2019-06-21', Action_Taken: 'COPT NO2 OIL SUMP, DRAINED CLEANED AND OIL RENEWED', unique_id: '25/10/2019 2:09:27 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34529, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'Few buttons on MF/HF keypad not functioning . Also,few pins of flat cable connected to the Keypad PCB found damaged making the above mentioned keys inoperational.', PO_Ref: 'STAI195045', VIQ_Question_ID: 8340, VIQ_QuestionNo: '4.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-18', Target_Date: '2019-08-30', Action_Taken: 'MF/HF equipment flat cable renewed and tested the GMDSS found working satisfactory.', unique_id: '25/10/2019 2:12:28 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34534, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Soot blower # 3 of LP side is stuck. Not operating', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-29', Target_Date: '2019-06-30', Action_Taken: 'Soot Blower LP3 removed from place , soot blower was stuck badly, sealing air passage was choked completely, same made free and cleared. Soot blower fitted back in place and tried out , satisfactory', unique_id: '25/10/2019 2:15:59 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34538, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 13, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Clutch lining of Vacuum pump of Emergency Fire Pump came off while trying out of the pump', PO_Ref: '', VIQ_Question_ID: 8558, VIQ_QuestionNo: '5.41', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-30', Action_Taken: 'Clutch lining renewed with the spare recd , pump tried out, satisfactory', unique_id: '25/10/2019 2:18:03 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34542, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-29', Defciency_Descp: 'Vibscanner is not operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received new vibscanner. ', unique_id: '25/10/2019 2:21:26 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34547, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-01', Defciency_Descp: 'Siren for wind Hi-Hi alarm not operational and only light is working.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-02', Target_Date: '2019-10-31', Action_Taken: 'Spares received at Singapore on 31/08/2019. Wind Hi-Hi siren and light replaced. Working satsifactorily', unique_id: '25/10/2019 2:25:15 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34551, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'The GMT time in the BilgeGuard is 11-12 minutes behind the actual GMT time', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-30', Action_Taken: 'CHANGED 15 PPM MONITOR. NOW DIFFERENCE IS 3 MINS', unique_id: '25/10/2019 2:29:07 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34555, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'One of the Personal Gas Meter MSA Altair 4X (Sr no. 06028737) Showing Error message on O2, CO & H2S sensor on starting the equipment', PO_Ref: '', VIQ_Question_ID: 8540, VIQ_QuestionNo: '5.23', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-09', Target_Date: '2019-08-30', Action_Taken: 'Replaced with the new gas meter received under warranty at GOLA, US on 09th July 2019', unique_id: '25/10/2019 2:32:38 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34560, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'The WBT gas detection system function giving Fault 19 and 17. and is inoperable. FAULT (19) - “No custom setup, using default setup” comes and later after 15-20 seconds the FAULT(17) – “Analyzing unit no answer” shows.', PO_Ref: '', VIQ_Question_ID: 8539, VIQ_QuestionNo: '5.22', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-08', Target_Date: '2019-08-30', Action_Taken: 'Makers technician attanded vessel at GOLA, US on 08th July 2019. Troubleshooting done, necessary spares changed by technician and reconfiguration done.', unique_id: '25/10/2019 2:37:17 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34564, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'UTI (Sr. No. G17710) showing error message on start up indicating ‘’No msg’’.', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Tape was unwinded to check for any damage and found tape damage at 60cm mark. Continuity test was done for the UTI to confirm the tape error.As per message from office as vessel have total 4 UTIs, so this faulty UTI to be landed ashore at next', unique_id: '25/10/2019 2:40:16 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34569, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-16', Defciency_Descp: 'WBT 1 (P) gauge showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-02', Target_Date: '2019-10-31', Action_Taken: 'Renewed sensor on 02nd Oct 2019.', unique_id: '25/10/2019 2:42:33 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34573, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-21', Defciency_Descp: 'The local touch panel of WHRS( EGB) does not operate with touch, however operational with mouse', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-20', Target_Date: '2019-11-30', Action_Taken: 'The touch screen panel renewed', unique_id: '25/10/2019 2:47:46 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34577, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-24', Defciency_Descp: 'HFO PFR P/P NO2 MAGNETIC COUPLING CASING HOLED', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-10', Target_Date: '2019-10-31', Action_Taken: 'CHANGED CAN OF THE COUPLING', unique_id: '25/10/2019 2:56:36 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34581, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-29', Defciency_Descp: 'KW not matching with KWh meter reading and which leads to high SFOC, diff in % utilization of AEs.Actually KWHR is not for present KW', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-15', Target_Date: '2019-10-31', Action_Taken: 'RESET THE KWH METER. NOW SHOWING VALUES CORRECTLY', unique_id: '25/10/2019 2:59:03 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34585, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-06', Defciency_Descp: 'M/E F.O. leak off alarm not coming in the AMS', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-10', Target_Date: '2019-09-30', Action_Taken: 'Changed the Net DI 16. found alarm stilll there. Then found that in the tag in the AMS the switch had shifted to Man. Changed back to Auto. It is working fine. Changed it back to old NET DI16. Still it is functional.', unique_id: '25/10/2019 3:06:56 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34589, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-12', Defciency_Descp: 'EGB exhasut gas outlet temperature probe giving wrong readings', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-15', Target_Date: '2019-09-30', Action_Taken: 'needs replacement. Shall raise RO for same. Entered in DD defect list', unique_id: '25/10/2019 3:13:00 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34593, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'UTI (Sr. No. G18578) Display becomes blurred everytime after 5-10 minutes of operation', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Interchanged with the Display unit of UTI G17710 which was to be landed ashore as per message from office. Now UTI G 18578 is in good working order', unique_id: '25/10/2019 3:24:54 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34597, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'Work shop AC OCR under rated ,getting tripped', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-09', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:35:14 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34601, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'STBD life boat control circuit switch damaged', PO_Ref: '', VIQ_Question_ID: 8546, VIQ_QuestionNo: '5.29', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-15', Action_Taken: 'Requisition received at Singapore on 31/08/2019. Control circuit replaced. Working satisfactorily now.', unique_id: '25/10/2019 3:37:27 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34605, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'Two wire programmable TX defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-26', Target_Date: '2019-10-30', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:42:18 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34609, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-25', Defciency_Descp: 'Scrubber p/p mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-08', Target_Date: '2019-08-15', Action_Taken: 'Mechanical sal renewed. Pump tried out.', unique_id: '25/10/2019 3:48:02 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34613, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-08-08', Defciency_Descp: 'Cover for General Alarm switch on Port/Stbd boat deck broken', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-11', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:50:01 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34617, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-11', Defciency_Descp: 'The battery for BilgeMon 488 for OWS showing voltage 0.330 V against the required value of 2.5', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-31', Action_Taken: 'CHANGED 15 PPM SENSOR WITH NEW', unique_id: '25/10/2019 3:52:18 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34622, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-16', Defciency_Descp: 'Fire and GS p/p 1 mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-23', Target_Date: '2019-08-30', Action_Taken: 'Pump dismantled and overhauled, mech seal and bottom line brearing renewed', unique_id: '25/10/2019 3:57:52 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34626, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-07-18', Defciency_Descp: 'Stbd windlass Hydraulic brake Cylinder leaking from Cylinder top seal during anchoring operations', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-26', Target_Date: '2019-08-30', Action_Taken: 'Road seal and scrapper ring renewed. Brake tried out and found satisfactory. No further leaks observed.', unique_id: '25/10/2019 4:23:34 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34631, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-20', Defciency_Descp: 'IG 43 - deck isolation valave for the IG Line after the IG NRV was found to be leaking and not holding', PO_Ref: 'STAI190182', VIQ_Question_ID: 8593, VIQ_QuestionNo: '8.25', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-25', Target_Date: '2019-10-30', Action_Taken: 'IG 43 valve removed from location and found valve disc damaged. Valve disc was builded and put back in plce again. But still minor leak exist. RO raised for Valve disc and seat ring. Valve renewed.', unique_id: '25/10/2019 4:26:54 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34635, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler Feed water pumps motor #1 and #3 cooling Fan damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received the spare and changed the cooling fan. ', unique_id: '25/10/2019 12:03:13 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34640, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-20', Defciency_Descp: 'Kyma Engine Analyser defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-11-30', Action_Taken: 'Changed the cable connecting to computer by Technician', unique_id: '25/10/2019 2:44:53 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34644, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-04', Defciency_Descp: 'Anemometer- Wind speed transmitter found not working', PO_Ref: '', VIQ_Question_ID: 8326, VIQ_QuestionNo: '4.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-13', Target_Date: '2019-01-14', Action_Taken: 'Old repaired Anemometer transmitter installed. Tested and found operational.', unique_id: '24/10/2019 9:47:45 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34648, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-11', Defciency_Descp: 'FWD air horn non operational', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Air horn compressor and motor overhauled , fitted back and tried out, working satisfactory.', unique_id: '24/10/2019 9:52:15 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34652, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'IG Fan drain line in 3rd deck platform found leaking due to crack in the pipeline.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-12', Target_Date: '2019-01-12', Action_Taken: 'New pipe fabricated wid stainless steel pipe and flange . Pipe replaced with fabricated one and tested, found satisfactory.', unique_id: '24/10/2019 9:57:34 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34656, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'Main engine unit no.4 cyl.jacket inlet pipe leaking from flange joint.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-16', Target_Date: '2019-01-16', Action_Taken: 'Gasket replaced and boxed back with stainless steel bolts.', unique_id: '24/10/2019 9:59:53 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34660, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-14', Defciency_Descp: 'Hydraulic oil leakage from FWD windlass (PORT) High/Low control lever (DIRECTIONAL CONTROL VALVE)', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Both seals and o rings changed for the Directional control valve andf tested, and found working satisfactory.', unique_id: '24/10/2019 10:02:27 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34664, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'COPT # 2 Discharge line flange valve no.260 in pump room found traces of oil leakage.', PO_Ref: '', VIQ_Question_ID: 8615, VIQ_QuestionNo: '8.44', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-31', Target_Date: '2019-04-28', Action_Taken: 'Oil traces cleaned and flange tightened,no oil leakage', unique_id: '24/10/2019 10:06:01 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34668, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Stenciling of various remote sounding boxes for ballast tanks missing', PO_Ref: '', VIQ_Question_ID: 8426, VIQ_QuestionNo: '11.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-04-28', Action_Taken: 'Steciling carried out for all remote sounding boxes for ballast tanks', unique_id: '24/10/2019 10:11:45 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34672, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'One light in pump room 2nd deck not working.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-01-28', Action_Taken: 'Light renewed', unique_id: '24/10/2019 10:14:28 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34676, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Pressure regulator in air line for sea chest testing not fitted', PO_Ref: '', VIQ_Question_ID: 8351, VIQ_QuestionNo: '6.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-12', Target_Date: '2019-04-28', Action_Taken: 'Pressure regulator fitted in air line for sea chest testing.', unique_id: '24/10/2019 10:17:16 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34680, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 6, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Windlass pinion bearing found not greased and grease point not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-04-28', Action_Taken: 'Windlass pinion bearing greasing carried out and grease point marked.', unique_id: '24/10/2019 10:19:29 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 6, insertId: 34685, serverStatus: 2, warningCount: 3, message: '&Records: 6 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Helicopter equipement CO2 extinguishers not as per requirement', PO_Ref: '', VIQ_Question_ID: 8520, VIQ_QuestionNo: '5.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-11', Target_Date: '2019-04-28', Action_Taken: 'CO2 extinguishers installed as per requirement.', unique_id: '24/10/2019 10:24:15 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34691, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 3 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-03', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed soon after receiving new cable.', unique_id: '24/10/2019 10:26:52 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34696, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'EGB bellow between LP and HP evaporator had traces of leakage, to be checked , cleaned and painted.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-17', Target_Date: '2019-04-28', Action_Taken: 'Bellow inspected, no leakes found.Bellow area cleaned and painted.', unique_id: '24/10/2019 10:29:52 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34701, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'T/C suction room door not easy to open. To ease up and grease.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-06', Target_Date: '2019-11-08', Action_Taken: 'DOOR EASED UP. ', unique_id: '2019-11-08 19:58:10.999' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34706, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Steering gear room door self-closing mechanism needs to adjust as door remains in open condition.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-07', Action_Taken: 'Door adjusted. ', unique_id: '2019-11-08 20:07:39.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34710, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Chlorine dosing pump of STP was running but no liquid passing. To be purged and checked regularly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-05', Target_Date: '2019-11-05', Action_Taken: 'Checked and purged. ', unique_id: '2019-08-11 20:09:57.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34714, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler outside ECR not operational. Cooler Compressor not running.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-09', Target_Date: '2019-11-15', Action_Taken: 'Leak rectified and cooler put in use', unique_id: '2019-08-11 19:41:53.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34718, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- 48 { C_Type: '', InfoSharing_Flag: 'false', InfoSharing_Flag_Change: 'false', Ship_ID: '48', Record_Date: 'null', Inspection_Type_ID: 'null', Deficiency_Type_ID: 'null', Defciency_Descp: 'null', Action_Taken: 'null', Target_Date: 'null', Completion_Date: 'null', Superident_Remarks: 'null', Status_ID: 'null', PSCRefNumbers: 'null', AreaObservation: 'null', Risk_Value: 'null', PSC_Ref_ID: 'null', Area_Observation_ID: 'null', Observeration_code: 'Ship Staff', DryDock_Flag: 'false', Critical_Item_Flag: 'false', Complete_Flag: '', currentPage: '0', itemsPerPage: '20' } SELECT MAX(ID) as LAST_EXPORT_ID,(SELECT ID FROM `tbl_defect_export` WHERE `export_file` = '48_1573611069280.xlsm') as IMPORT_ID FROM tbl_defect_export WHERE 1=1 and Ship_ID = 48 ORDER BY ID DESC [ RowDataPacket { LAST_EXPORT_ID: 214, IMPORT_ID: 203 } ] SELECT * FROM tbl_defect_export WHERE 1=1 and Ship_ID = 48 and export_file = '48_1573611069280.xlsm' ORDER BY ID DESC ----xlData===== [ { ID: 5415, 'UNIQUE ID': '25/10/2019 2:53:02 PM', 'Date Recorded': 2019-06-21T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Display for OWS Bilge Mon not clear when seen from front, however can be seen at certain angle', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Requires replacement, last changed on 29 dec 2018 , as per email correspondences , to be claimed under guarantee. ', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': 'STAI190136', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5428, 'UNIQUE ID': '25/10/2019 3:59:57 PM', 'Date Recorded': 2019-10-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Grey water discharge pump not taking suction.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.31', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump needs overhauling ( need to change mouth ring). Raised RO. Awaiting spares', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': 'STAI190222', 'Status Code': 'Waiting spare', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5431, 'UNIQUE ID': '24/10/2019 11:58:45 PM', 'Date Recorded': 2019-03-14T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'CCTV -CAMERA NO: 2 (FWD) NOT WORKING , CAMERA NO: 3 ( FUNNEL DECK ) -ERRATIC ', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'ISPS Related', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '7.6', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CMERA NO : 2 (FWD - WHILE SELECTING GIVING ERROR DISPLAY ( COMPOSITE NO SYNC ) , CAMERA NO : 3 ( FUNNEL DCK ) NOT WORKING WITH DIRECT SELECTION OF NO : 3 CAMERA .WORK IN PROGRESS . OFFICE ADVISE SOUGHT ', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5434, 'UNIQUE ID': '25/10/2019 3:17:08 PM', 'Date Recorded': 2019-07-18T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'APK WBT gauge showing erratic reading', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.8', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'During Ballast operation at US, observed that when the tank is empty, the gauge is showing ballast tank level at 0.90 mtrs. And when the ballasting of APK was being carried out, it was not corrosponding to the relevent change in sounding of the tank. Req raised .Awaiting spares', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': 'STAI190182', 'Status Code': 'Waiting spare', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5935, 'UNIQUE ID': '2019-08-11 09:37:39.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Mooring wires are covered with mud due to use in yard. Cleaning and greasing required.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related,External Factors', 'VIQ Ref Number': '9.17', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All mooring wires planned for greasing in this ballast passage.', 'Target Date': 2020-02-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5937, 'UNIQUE ID': '2019-08-11 09:46:40.999', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Various tank domes of WBT and COT has rust weep marks. Derusting and painting required.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '8.18', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'derusting planned in this ballast passage to US', 'Target Date': 2020-01-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5938, 'UNIQUE ID': '2019-08-11 10:25:48.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'All the PV valves inspection date stencil to change.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.21', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'stencilling to be done on all PV valve.', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'In progress', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5939, 'UNIQUE ID': '2019-08-11 10:29:34.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Outside pump room Stbd side air valve leaking, To be renewed.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.4', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'air manifold valve to be renewed.', 'Target Date': 2019-11-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5941, 'UNIQUE ID': '2019-08-11 10:45:11.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Fire line pipe in scrubber room, just above the main power panel vibrates a lot at higher RPM. More supports to be welded. ', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '11.5', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'fitting of extra supports on the pipeline planned', 'Target Date': 2019-11-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5944, 'UNIQUE ID': '2019-08-11 19:49:28.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'MSDS and PPE to place in BWTS room for neutralizing chemicals.', 'Equipment Categories': 'Cargo Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Inappropriate Procedure', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'To put MSDS AND PPE', 'Target Date': 2019-11-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5945, 'UNIQUE ID': '2019-11-08 19:51:48.999', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Various electrical insulation mat in E/R and emergency DG room are deteriorated or salt soaked. To be renewed.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Inappropriate Procedure', 'VIQ Ref Number': '11.11', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'TO REPLACE THE INSULATION MATS', 'Target Date': 2019-11-14T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'In progress', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5946, 'UNIQUE ID': '2019-11-08 20:02:45.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Zebra stripe sticker to put in the newly installed low head pipe in ER bottom platform', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'To put stripe stickers. ', 'Target Date': 2019-11-12T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5950, 'UNIQUE ID': '2019-11-08 20:13:51.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'ME LO auto filter shaft seal leaking. To be renewed', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Will be renewed in the first oppurtunity', 'Target Date': 2019-12-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5951, 'UNIQUE ID': '2019-08-11 20:17:42.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Economiser surrounding to clean and paint', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'To be painted. ', 'Target Date': 2019-12-08T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'In progress', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5365, 'UNIQUE ID': '24/10/2019 10:38:50 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Main deck port side,U - Clamps on hydraulic lines, FW lines and air lines found rusted.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related,External Factors', 'VIQ Ref Number': '11.5', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All rusts removed and painted.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5366, 'UNIQUE ID': '24/10/2019 10:41:44 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'SIP\'S around the accommodation not clearly marked.', 'Equipment Categories': 'Hull & Tanks', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'External Factors,Human Error', 'VIQ Ref Number': '11.6', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'SIP markings completed.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-01T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5367, 'UNIQUE ID': '24/10/2019 10:43:36 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'ME UNIT # 6 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Cable renewed.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5368, 'UNIQUE ID': '24/10/2019 10:46:03 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Mooring wires dry and rusty not greased using wire rope greaser.', 'Equipment Categories': 'Deck Mach.,Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related,Human Error', 'VIQ Ref Number': '9.17', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All mooring wires greasing carried out.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-22T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5369, 'UNIQUE ID': '24/10/2019 10:48:36 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Port MGPS CU-AL anode showing error.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Defective control PCB for CU and AL-Anode replaced with new spare Port MGPS is operational.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-22T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5370, 'UNIQUE ID': '24/10/2019 10:50:32 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Dead man alarm indication light in pump room entrance not operational.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.11', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Received spare. Modified the switch and fitted back. It is working now.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5371, 'UNIQUE ID': '24/10/2019 10:59:49 PM', 'Date Recorded': 2019-01-30T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Port Side ECDIS unit on Bridge Buzzer for alarm is not working.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '', 'Risk Value of Obs': '', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Replaced operation circuit for ECDIS 2 (part No. OPU CCK-976 (PC640,7PCRD1796B)). Buzzer working satisfactorily.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5372, 'UNIQUE ID': '24/10/2019 11:05:55 PM', 'Date Recorded': 2019-02-06T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main engine # 6 unit jacket water outlet temperature reading shows erratic', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Temperature sensor renewed and working satisfactory.', 'Target Date': 2019-02-06T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-06T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5373, 'UNIQUE ID': '24/10/2019 11:07:47 PM', 'Date Recorded': 2019-02-16T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Vacuum toilet system port side line in operational', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Vacuum toilet line - Port side blockage rectified by flushing with water and air', 'Target Date': 2019-02-16T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-16T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5374, 'UNIQUE ID': '24/10/2019 11:09:56 PM', 'Date Recorded': 2019-02-18T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Sewage overboard valve - minor leakage ( 2/3 drop/day) through the storm valve body at the Engine room bottom floor on port side', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Temporary measures have been taken with UW and normal steel putty and currently no sign of leakage. New valve has been ordered. In order to renew the valve plugging of Overboard line is required.Sewage overboard valve renewed at Singapore anchorage.', 'Target Date': 2019-05-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-21T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5375, 'UNIQUE ID': '24/10/2019 11:11:49 PM', 'Date Recorded': 2019-02-21T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main CSW pump no.1 - Discharge pressure gauge showing incorrect value', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Root valve for the pressure gauge renewed and line blown through - Gauge is operational.', 'Target Date': 2019-02-22T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-21T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5376, 'UNIQUE ID': '24/10/2019 11:38:34 PM', 'Date Recorded': 2019-03-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Fresh water generator 1- Ejector pump sea water suction valve not holding, unable to isolate the pump.', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'valve Renewed', 'Target Date': 2019-10-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5377, 'UNIQUE ID': '24/10/2019 11:42:28 PM', 'Date Recorded': 2019-03-02T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Citadel Iridium Phone displaying "SIM Card Blocked" and can\'t be used.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '7.6', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Troubleshooting carried out with the help of IT departments. Phone is operational now.', 'Target Date': 2019-03-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5378, 'UNIQUE ID': '24/10/2019 11:47:00 PM', 'Date Recorded': 2019-03-07T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'ME Jacket pre heater steam inlet pressure gauge needle found broken.', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure gauge renewed.', 'Target Date': 2019-03-07T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-08T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5379, 'UNIQUE ID': '24/10/2019 11:49:58 PM', 'Date Recorded': 2019-03-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'ME- Aft Aux. Blower cooling fan blades found damaged', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'ME- Aft Aux. Blower cooling fan renewed and tested.', 'Target Date': 2019-03-10T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5380, 'UNIQUE ID': '25/10/2019 8:39:58 AM', 'Date Recorded': 2019-03-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'TG condenser –Condensate water inlet to vapour chamber pressure gauge found faulty', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure gauge renewed.', 'Target Date': 2019-03-24T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-24T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5381, 'UNIQUE ID': '25/10/2019 8:54:11 AM', 'Date Recorded': 2019-03-26T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main Engine -Fuel oil Viscotherm is showing erratic reading.', 'Equipment Categories': 'Elect. Mach. & Equip.,ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Sensor received and changed. Showing viscosity correctly', 'Target Date': 2019-06-25T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5382, 'UNIQUE ID': '25/10/2019 8:56:53 AM', 'Date Recorded': 2019-03-27T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Auxiliary Engine - T/C Exhaust gas inlet temperature sensor -A found faulty', 'Equipment Categories': 'Aux. Engine,Elect. Mach. & Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Sensor renewed and is operational.', 'Target Date': 2019-03-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-27T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5383, 'UNIQUE ID': '25/10/2019 8:59:47 AM', 'Date Recorded': 2019-03-29T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'WBT 3 (P) and WBT 5 (P) gauges showing erratic reading', 'Equipment Categories': 'Hull & Tanks', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.8', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': '5P & 3P WBT sensor renewed.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-01T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5384, 'UNIQUE ID': '25/10/2019 9:01:57 AM', 'Date Recorded': 2019-04-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Port windlass brake cylinder top cover seal slightly leaking', 'Equipment Categories': 'Deck Mach.,Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Scraper ring, wear ring and rod seal renewed for top cover and tested - working satisfactory.', 'Target Date': 2019-04-02T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-01T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5385, 'UNIQUE ID': '25/10/2019 9:03:51 AM', 'Date Recorded': 2019-04-16T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Pump Room Blower Motor Low Insulation.', 'Equipment Categories': 'Deck Mach.,Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.38', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump Room fan motor inside the terminal box one wire connection to motor winding got grounded, same replaced with new wire and motor both bearing changed with new spare, blower is operational', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-24T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5386, 'UNIQUE ID': '25/10/2019 9:07:39 AM', 'Date Recorded': 2019-04-28T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Forward whistle horn , reported not working', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '', 'Risk Value of Obs': '', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Motor electrical connection disconnected to facilitate the repair work of the whistle. Complete unit removed from its place and taken to workshop. Dismantled the unit and found connecting rod bearing completely damaged. Same replaced with old', 'Target Date': 2019-04-29T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5387, 'UNIQUE ID': '25/10/2019 9:09:58 AM', 'Date Recorded': 2019-05-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'CONNING DISPLAY ,PROCESSOR FAN FAIL', 'Equipment Categories': 'Aux. Mach.,Nav & comm. equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.1', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'processor fan replaced by CODAR technician at Singapore', 'Target Date': 2019-08-01T00:00:00.000Z, 'PO Ref No.': 'STAI190081', 'Status Code': 'Completed', 'Date Completed': 2019-05-21T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5388, 'UNIQUE ID': '25/10/2019 8:16:31 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Aux Boiler F.O. pump supply Mechanical seal leaking', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Mechanical Seal changed , P/P tried out satisfactory', 'Target Date': 2019-08-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5389, 'UNIQUE ID': '25/10/2019 11:38:10 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Frequency controllers for MSW pumps #3 not working', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'FREQUENCY CONTROLLER FOR NO1 AND 2 ATTENDED ON 15/06/2019 AND NOW WORKING SATISFACTORY, As per office instructions Frequency controller not to be changed. Pump to', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5390, 'UNIQUE ID': '25/10/2019 11:41:49 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'VACUUMARATOR PUMP NO.1 END PLATE BADLY WORN OUT .', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump working satisfactory. Parts kept as spare. To be changed if issue arises', 'Target Date': 2019-08-25T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5391, 'UNIQUE ID': '25/10/2019 11:45:20 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'IGS ECR Main control valve leaking when IG is venting to atmosphere and main blower in use', 'Equipment Categories': 'Inert Gas', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Valve seat renewed. Tried out . No leakage observed', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': 'STAI 190078', 'Status Code': 'Completed', 'Date Completed': 2019-08-05T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5392, 'UNIQUE ID': '25/10/2019 11:48:09 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'GE fuel line Pr regulating v/v 9k leaking', 'Equipment Categories': 'Aux. Engine', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Confirmed the operation during LSMGO and HFO. Found not leaking. Holdingnow. Under observation. Vessel received spare. Kept standby', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': 'STAI190112', 'Status Code': 'Completed', 'Date Completed': 2019-08-20T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5393, 'UNIQUE ID': '25/10/2019 11:51:49 AM', 'Date Recorded': 2019-05-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Control air dryer #1 not working', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-05T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5394, 'UNIQUE ID': '25/10/2019 11:54:11 AM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'No 1 boiler burner platform has steam / leakage. Looks like same', 'Equipment Categories': 'Boiler', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'steam regulating valve. To be', 'Target Date': 2019-05-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-24T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5395, 'UNIQUE ID': '25/10/2019 11:56:47 AM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Air bottles auto drain valve is kept shut. Same to be opened and all the crew to be advised accordingly.', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'VALVES OPENED AND CREW ADVISED OF THE OPERATION', 'Target Date': 2019-05-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-22T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5396, 'UNIQUE ID': '25/10/2019 12:00:28 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Area below the blower in steering Gear room needs to be cleaned.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.29', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Area cleaned and painted', 'Target Date': 2019-07-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5397, 'UNIQUE ID': '25/10/2019 1:36:51 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'In steam line there is steam / water leak from dump bypass valve and air ejector steam inlet valve. To be rectified by closing main steam stop valve', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'gasket renewed', 'Target Date': 2019-07-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-30T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5398, 'UNIQUE ID': '25/10/2019 1:40:19 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Provision compressor low pressure gauge to renew', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure Gauge renewed', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-02T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5399, 'UNIQUE ID': '25/10/2019 1:44:14 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Port side bunker manifold pressure gauge to renew, as same showing wrong indication.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure Gauge renewed', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-30T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5400, 'UNIQUE ID': '25/10/2019 1:50:47 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'All 3 Aft winches gear case relief valve spring is missing. To replace.', 'Equipment Categories': 'Deck Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.14', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Springs replaced.', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-14T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5401, 'UNIQUE ID': '25/10/2019 1:56:01 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Stbd side pump room blower motor top cover is temporarily repaired by cold work. New cover to fabricate and fit.', 'Equipment Categories': 'Deck Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Top cover brought in E/R workshop and fabricated', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5402, 'UNIQUE ID': '25/10/2019 2:07:01 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'T/C air intake room cleaning required.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Human Error', 'VIQ Ref Number': '10.29', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Gratings removed, chipped and painted.', 'Target Date': 2019-07-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-20T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5403, 'UNIQUE ID': '25/10/2019 2:09:27 PM', 'Date Recorded': 2019-05-25T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'COPT#2 Oil caution remark from shore analysis', 'Equipment Categories': 'Cargo Mach.,Deck Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.7', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'COPT NO2 OIL SUMP, DRAINED CLEANED AND OIL RENEWED', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5404, 'UNIQUE ID': '25/10/2019 2:12:28 PM', 'Date Recorded': 2019-05-25T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Few buttons on MF/HF keypad not functioning . Also,few pins of flat cable connected to the Keypad PCB found damaged making the above mentioned keys inoperational.', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '4.21', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'MF/HF equipment flat cable renewed and tested the GMDSS found working satisfactory.', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': 'STAI195045', 'Status Code': 'Completed', 'Date Completed': 2019-07-18T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5405, 'UNIQUE ID': '25/10/2019 2:15:59 PM', 'Date Recorded': 2019-05-27T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Soot blower # 3 of LP side is stuck. Not operating', 'Equipment Categories': 'Boiler', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Soot Blower LP3 removed from place , soot blower was stuck badly, sealing air passage was choked completely, same made free and cleared. Soot blower fitted back in place and tried out , satisfactory', 'Target Date': 2019-06-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5406, 'UNIQUE ID': '25/10/2019 2:18:03 PM', 'Date Recorded': 2019-05-27T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment,Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Clutch lining of Vacuum pump of Emergency Fire Pump came off while trying out of the pump', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Emgcy. Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.41', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Clutch lining renewed with the spare recd , pump tried out, satisfactory', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5407, 'UNIQUE ID': '25/10/2019 2:21:26 PM', 'Date Recorded': 2019-05-29T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Vibscanner is not operational', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Received new vibscanner. ', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5408, 'UNIQUE ID': '25/10/2019 2:25:15 PM', 'Date Recorded': 2019-06-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Siren for wind Hi-Hi alarm not operational and only light is working.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received at Singapore on 31/08/2019. Wind Hi-Hi siren and light replaced. Working satsifactorily', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-02T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5409, 'UNIQUE ID': '25/10/2019 2:29:07 PM', 'Date Recorded': 2019-06-11T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment,Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The GMT time in the BilgeGuard is 11-12 minutes behind the actual GMT time', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CHANGED 15 PPM MONITOR. NOW DIFFERENCE IS 3 MINS', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5410, 'UNIQUE ID': '25/10/2019 2:32:38 PM', 'Date Recorded': 2019-06-11T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'One of the Personal Gas Meter MSA Altair 4X (Sr no. 06028737) Showing Error message on O2, CO & H2S sensor on starting the equipment', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.23', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Replaced with the new gas meter received under warranty at GOLA, US on 09th July 2019', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5411, 'UNIQUE ID': '25/10/2019 2:37:17 PM', 'Date Recorded': 2019-06-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The WBT gas detection system function giving Fault 19 and 17. and is inoperable. FAULT (19) - “No custom setup, using default setup” comes and later after 15-20 seconds the FAULT(17) – “Analyzing unit no answer” shows.', 'Equipment Categories': 'Critical Equip.,Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.22', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Makers technician attanded vessel at GOLA, US on 08th July 2019. Troubleshooting done, necessary spares changed by technician and reconfiguration done.', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-08T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5412, 'UNIQUE ID': '25/10/2019 2:40:16 PM', 'Date Recorded': 2019-06-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'UTI (Sr. No. G17710) showing error message on start up indicating ‘’No msg’’.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.12', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Tape was unwinded to check for any damage and found tape damage at 60cm mark. Continuity test was done for the UTI to confirm the tape error.As per message from office as vessel have total 4 UTIs, so this faulty UTI to be landed ashore at next', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5413, 'UNIQUE ID': '25/10/2019 2:42:33 PM', 'Date Recorded': 2019-06-16T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'WBT 1 (P) gauge showing erratic reading', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.8', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Renewed sensor on 02nd Oct 2019.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-02T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5414, 'UNIQUE ID': '25/10/2019 2:47:46 PM', 'Date Recorded': 2019-06-21T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The local touch panel of WHRS( EGB) does not operate with touch, however operational with mouse', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'The touch screen panel renewed', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-20T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5416, 'UNIQUE ID': '25/10/2019 2:56:36 PM', 'Date Recorded': 2019-06-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'HFO PFR P/P NO2 MAGNETIC COUPLING CASING HOLED', 'Equipment Categories': 'Purifier', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CHANGED CAN OF THE COUPLING', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5417, 'UNIQUE ID': '25/10/2019 2:59:03 PM', 'Date Recorded': 2019-06-29T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'KW not matching with KWh meter reading and which leads to high SFOC, diff in % utilization of AEs.Actually KWHR is not for present KW', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'RESET THE KWH METER. NOW SHOWING VALUES CORRECTLY', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5418, 'UNIQUE ID': '25/10/2019 3:06:56 PM', 'Date Recorded': 2019-07-06T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'M/E F.O. leak off alarm not coming in the AMS', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Changed the Net DI 16. found alarm stilll there. Then found that in the tag in the AMS the switch had shifted to Man. Changed back to Auto. It is working fine. Changed it back to old NET DI16. Still it is functional.', 'Target Date': 2019-09-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5419, 'UNIQUE ID': '25/10/2019 3:13:00 PM', 'Date Recorded': 2019-07-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'EGB exhasut gas outlet temperature probe giving wrong readings', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'needs replacement. Shall raise RO for same. Entered in DD defect list', 'Target Date': 2019-09-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5420, 'UNIQUE ID': '25/10/2019 3:24:54 PM', 'Date Recorded': 2019-07-23T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'UTI (Sr. No. G18578) Display becomes blurred everytime after 5-10 minutes of operation', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.12', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Interchanged with the Display unit of UTI G17710 which was to be landed ashore as per message from office. Now UTI G 18578 is in good working order', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5421, 'UNIQUE ID': '25/10/2019 3:35:14 PM', 'Date Recorded': 2019-07-23T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Work shop AC OCR under rated ,getting tripped', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5422, 'UNIQUE ID': '25/10/2019 3:37:27 PM', 'Date Recorded': 2019-07-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'STBD life boat control circuit switch damaged', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.29', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Requisition received at Singapore on 31/08/2019. Control circuit replaced. Working satisfactorily now.', 'Target Date': 2019-10-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5423, 'UNIQUE ID': '25/10/2019 3:42:18 PM', 'Date Recorded': 2019-07-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Two wire programmable TX defective', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5424, 'UNIQUE ID': '25/10/2019 3:48:02 PM', 'Date Recorded': 2019-07-25T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Scrubber p/p mech seal leaking', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.31', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Mechanical sal renewed. Pump tried out.', 'Target Date': 2019-08-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-08T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5425, 'UNIQUE ID': '25/10/2019 3:50:01 PM', 'Date Recorded': 2019-08-08T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Cover for General Alarm switch on Port/Stbd boat deck broken', 'Equipment Categories': 'Elect. Mach. & Equip.,LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5426, 'UNIQUE ID': '25/10/2019 3:52:18 PM', 'Date Recorded': 2019-08-11T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The battery for BilgeMon 488 for OWS showing voltage 0.330 V against the required value of 2.5', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CHANGED 15 PPM SENSOR WITH NEW', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5427, 'UNIQUE ID': '25/10/2019 3:57:52 PM', 'Date Recorded': 2019-08-16T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment,Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Fire and GS p/p 1 mech seal leaking', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.31', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump dismantled and overhauled, mech seal and bottom line brearing renewed', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-23T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5429, 'UNIQUE ID': '25/10/2019 4:23:34 PM', 'Date Recorded': 2019-07-18T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Stbd windlass Hydraulic brake Cylinder leaking from Cylinder top seal during anchoring operations', 'Equipment Categories': 'Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Road seal and scrapper ring renewed. Brake tried out and found satisfactory. No further leaks observed.', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5430, 'UNIQUE ID': '25/10/2019 4:26:54 PM', 'Date Recorded': 2019-07-20T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'IG 43 - deck isolation valave for the IG Line after the IG NRV was found to be leaking and not holding', 'Equipment Categories': 'Cargo Mach.,Inert Gas', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.25', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'IG 43 valve removed from location and found valve disc damaged. Valve disc was builded and put back in plce again. But still minor leak exist. RO raised for Valve disc and seat ring. Valve renewed.', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': 'STAI190182', 'Status Code': 'Completed', 'Date Completed': 2019-10-25T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5432, 'UNIQUE ID': '25/10/2019 12:03:13 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Aux Boiler Feed water pumps motor #1 and #3 cooling Fan damaged', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Received the spare and changed the cooling fan. ', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5433, 'UNIQUE ID': '25/10/2019 2:44:53 PM', 'Date Recorded': 2019-06-20T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Kyma Engine Analyser defective', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Changed the cable connecting to computer by Technician', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5435, 'UNIQUE ID': '24/10/2019 9:47:45 PM', 'Date Recorded': 2019-01-04T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Anemometer- Wind speed transmitter found not working', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '4.7', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Old repaired Anemometer transmitter installed. Tested and found operational.', 'Target Date': 2019-01-14T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-13T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5436, 'UNIQUE ID': '24/10/2019 9:52:15 PM', 'Date Recorded': 2019-01-11T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'FWD air horn non operational', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Air horn compressor and motor overhauled , fitted back and tried out, working satisfactory.', 'Target Date': 2019-01-18T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-18T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5437, 'UNIQUE ID': '24/10/2019 9:57:34 PM', 'Date Recorded': 2019-01-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'IG Fan drain line in 3rd deck platform found leaking due to crack in the pipeline.', 'Equipment Categories': 'Inert Gas', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'New pipe fabricated wid stainless steel pipe and flange . Pipe replaced with fabricated one and tested, found satisfactory.', 'Target Date': 2019-01-12T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5438, 'UNIQUE ID': '24/10/2019 9:59:53 PM', 'Date Recorded': 2019-01-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main engine unit no.4 cyl.jacket inlet pipe leaking from flange joint.', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Gasket replaced and boxed back with stainless steel bolts.', 'Target Date': 2019-01-16T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-16T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5439, 'UNIQUE ID': '24/10/2019 10:02:27 PM', 'Date Recorded': 2019-01-14T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Hydraulic oil leakage from FWD windlass (PORT) High/Low control lever (DIRECTIONAL CONTROL VALVE)', 'Equipment Categories': 'Deck Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Both seals and o rings changed for the Directional control valve andf tested, and found working satisfactory.', 'Target Date': 2019-01-18T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-18T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5440, 'UNIQUE ID': '24/10/2019 10:06:01 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'COPT # 2 Discharge line flange valve no.260 in pump room found traces of oil leakage.', 'Equipment Categories': 'Cargo Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.44', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Oil traces cleaned and flange tightened,no oil leakage', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5441, 'UNIQUE ID': '24/10/2019 10:11:45 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Stenciling of various remote sounding boxes for ballast tanks missing', 'Equipment Categories': 'Hull & Tanks', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'Human Error', 'VIQ Ref Number': '11.7', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Steciling carried out for all remote sounding boxes for ballast tanks', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5442, 'UNIQUE ID': '24/10/2019 10:14:28 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'One light in pump room 2nd deck not working.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.11', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Light renewed', 'Target Date': 2019-01-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5443, 'UNIQUE ID': '24/10/2019 10:17:16 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Pressure regulator in air line for sea chest testing not fitted', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related,Human Error', 'VIQ Ref Number': '6.4', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure regulator fitted in air line for sea chest testing.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5444, 'UNIQUE ID': '24/10/2019 10:19:29 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Windlass pinion bearing found not greased and grease point not clearly marked.', 'Equipment Categories': 'Deck Mach.,Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related,Human Error', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Windlass pinion bearing greasing carried out and grease point marked.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-06T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5445, 'UNIQUE ID': '24/10/2019 10:24:15 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Helicopter equipement CO2 extinguishers not as per requirement', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Human Error,Knowledge Based', 'VIQ Ref Number': '5.4', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CO2 extinguishers installed as per requirement.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5446, 'UNIQUE ID': '24/10/2019 10:26:52 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'ME UNIT # 3 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related,Inappropriate Procedure', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Cable renewed soon after receiving new cable.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5447, 'UNIQUE ID': '24/10/2019 10:29:52 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'EGB bellow between LP and HP evaporator had traces of leakage, to be checked , cleaned and painted.', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Bellow inspected, no leakes found.Bellow area cleaned and painted.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-17T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5940, 'UNIQUE ID': '2019-08-11 19:41:53.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Water cooler outside ECR not operational. Cooler Compressor not running.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Leak rectified and cooler put in use', 'Target Date': 2019-11-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 5947, 'UNIQUE ID': '2019-11-08 19:58:10.999', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'T/C suction room door not easy to open. To ease up and grease.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'DOOR EASED UP. ', 'Target Date': 2019-11-08T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-06T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5948, 'UNIQUE ID': '2019-11-08 20:07:39.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Steering gear room door self-closing mechanism needs to adjust as door remains in open condition.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Inappropriate Procedure', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Door adjusted. ', 'Target Date': 2019-11-07T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 5949, 'UNIQUE ID': '2019-08-11 20:09:57.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Chlorine dosing pump of STP was running but no liquid passing. To be purged and checked regularly.', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Checked and purged. ', 'Target Date': 2019-11-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-05T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { 'UNIQUE ID': 2019-11-08T10:42:57.000Z, 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Drain near both aft E/R blower are choked. To be cleared.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Structural Condn. / WT integrity ', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': 6.2, 'Risk Value of Obs': 'High', 'PSC Ref Number': 'Not Applicable', 'PSC MOU ID': 'Not Applicable', 'Action Taken or Required': 'Drain line opened up for both blowers and cleared. ', 'Target Date': 2019-12-05T00:00:00.000Z, 'Status Code': 'Completed', 'Date Completed': 2019-11-13T00:00:00.000Z, Drydock: 'No', 'Audit Type': 'Internal' }, { 'UNIQUE ID': 2019-03-11T07:06:56.000Z, 'Date Recorded': 2019-10-31T00:00:00.000Z, 'Type of Deficiency': 'Breakdown', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Fwd Air horn not working.', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '4.7.3', 'Risk Value of Obs': 'High', 'PSC Ref Number': 'Not Applicable', 'PSC MOU ID': 'Not Applicable', 'Action Taken or Required': 'Spares received and renewed. Fog horn assembled and now in use', 'Target Date': 2019-11-30T00:00:00.000Z, 'Status Code': 'Completed', 'Date Completed': 2019-11-11T00:00:00.000Z, Drydock: 'No', 'Audit Type': 'Internal' }, { 'UNIQUE ID': 2019-08-11T19:37:25.000Z, 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Left over pneumatic pipe of old BWTS system in steering gear room to remove', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': 10.32, 'Risk Value of Obs': 'Very High', 'PSC Ref Number': 'Not Applicable', 'PSC MOU ID': 'Not Applicable', 'Action Taken or Required': 'All old pneumatic pipes removed and terminated. ', 'Target Date': 2019-11-15T00:00:00.000Z, 'Status Code': 'Completed', 'Date Completed': 2019-11-10T00:00:00.000Z, Drydock: 'No', 'Audit Type': 'External' }, ... 2 more items ] updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-06-21', Defciency_Descp: 'Display for OWS Bilge Mon not clear when seen from front, however can be seen at certain angle', PO_Ref: 'STAI190136', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-10-30', Action_Taken: 'Requires replacement, last changed on 29 dec 2018 , as per email correspondences , to be claimed under guarantee. ', unique_id: '25/10/2019 2:53:02 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:53:02 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 4, Record_Date: '2019-10-10', Defciency_Descp: 'Grey water discharge pump not taking suction.', PO_Ref: 'STAI190222', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'Pump needs overhauling ( need to change mouth ring). Raised RO. Awaiting spares', unique_id: '25/10/2019 3:59:57 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:59:57 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 10, Status_ID: 2, Record_Date: '2019-03-14', Defciency_Descp: 'CCTV -CAMERA NO: 2 (FWD) NOT WORKING , CAMERA NO: 3 ( FUNNEL DECK ) -ERRATIC ', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'CMERA NO : 2 (FWD - WHILE SELECTING GIVING ERROR DISPLAY ( COMPOSITE NO SYNC ) , CAMERA NO : 3 ( FUNNEL DCK ) NOT WORKING WITH DIRECT SELECTION OF NO : 3 CAMERA .WORK IN PROGRESS . OFFICE ADVISE SOUGHT ', unique_id: '24/10/2019 11:58:45 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:58:45 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 4, Record_Date: '2019-07-18', Defciency_Descp: 'APK WBT gauge showing erratic reading', PO_Ref: 'STAI190182', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'During Ballast operation at US, observed that when the tank is empty, the gauge is showing ballast tank level at 0.90 mtrs. And when the ballasting of APK was being carried out, it was not corrosponding to the relevent change in sounding of the tank. Req raised .Awaiting spares', unique_id: '25/10/2019 3:17:08 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:17:08 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Mooring wires are covered with mud due to use in yard. Cleaning and greasing required.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-02-05', Action_Taken: 'All mooring wires planned for greasing in this ballast passage.', unique_id: '2019-08-11 09:37:39.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 09:37:39.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Various tank domes of WBT and COT has rust weep marks. Derusting and painting required.', PO_Ref: '', VIQ_Question_ID: 8586, VIQ_QuestionNo: '8.18', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-01-05', Action_Taken: 'derusting planned in this ballast passage to US', unique_id: '2019-08-11 09:46:40.999' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 09:46:40.999' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'All the PV valves inspection date stencil to change.', PO_Ref: '', VIQ_Question_ID: 8589, VIQ_QuestionNo: '8.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'stencilling to be done on all PV valve.', unique_id: '2019-08-11 10:25:48.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 10:25:48.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Outside pump room Stbd side air valve leaking, To be renewed.', PO_Ref: '', VIQ_Question_ID: 8423, VIQ_QuestionNo: '11.4', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'air manifold valve to be renewed.', unique_id: '2019-08-11 10:29:34.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 10:29:34.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Fire line pipe in scrubber room, just above the main power panel vibrates a lot at higher RPM. More supports to be welded. ', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'fitting of extra supports on the pipeline planned', unique_id: '2019-08-11 10:45:11.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 10:45:11.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'MSDS and PPE to place in BWTS room for neutralizing chemicals.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-15', Action_Taken: 'To put MSDS AND PPE', unique_id: '2019-08-11 19:49:28.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 19:49:28.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Various electrical insulation mat in E/R and emergency DG room are deteriorated or salt soaked. To be renewed.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-14', Action_Taken: 'TO REPLACE THE INSULATION MATS', unique_id: '2019-11-08 19:51:48.999' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 19:51:48.999' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Zebra stripe sticker to put in the newly installed low head pipe in ER bottom platform', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-12', Action_Taken: 'To put stripe stickers. ', unique_id: '2019-11-08 20:02:45.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 20:02:45.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'ME LO auto filter shaft seal leaking. To be renewed', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-20', Action_Taken: 'Will be renewed in the first oppurtunity', unique_id: '2019-11-08 20:13:51.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 20:13:51.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Economiser surrounding to clean and paint', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-08', Action_Taken: 'To be painted. ', unique_id: '2019-08-11 20:17:42.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 20:17:42.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Main deck port side,U - Clamps on hydraulic lines, FW lines and air lines found rusted.', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-26', Target_Date: '2019-04-28', Action_Taken: 'All rusts removed and painted.', unique_id: '24/10/2019 10:38:50 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:38:50 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'SIP\'S around the accommodation not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8425, VIQ_QuestionNo: '11.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-01', Target_Date: '2019-04-28', Action_Taken: 'SIP markings completed.', unique_id: '24/10/2019 10:41:44 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:41:44 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 6 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed.', unique_id: '24/10/2019 10:43:36 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:43:36 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Mooring wires dry and rusty not greased using wire rope greaser.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-22', Target_Date: '2019-04-28', Action_Taken: 'All mooring wires greasing carried out.', unique_id: '24/10/2019 10:46:03 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:46:03 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Port MGPS CU-AL anode showing error.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-22', Target_Date: '2019-04-28', Action_Taken: 'Defective control PCB for CU and AL-Anode replaced with new spare Port MGPS is operational.', unique_id: '24/10/2019 10:48:36 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:48:36 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Dead man alarm indication light in pump room entrance not operational.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-09', Target_Date: '2019-10-31', Action_Taken: 'Received spare. Modified the switch and fitted back. It is working now.', unique_id: '24/10/2019 10:50:32 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:50:32 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-30', Defciency_Descp: 'Port Side ECDIS unit on Bridge Buzzer for alarm is not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-31', Action_Taken: 'Replaced operation circuit for ECDIS 2 (part No. OPU CCK-976 (PC640,7PCRD1796B)). Buzzer working satisfactorily.', unique_id: '24/10/2019 10:59:49 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:59:49 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-06', Defciency_Descp: 'Main engine # 6 unit jacket water outlet temperature reading shows erratic', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-02-06', Action_Taken: 'Temperature sensor renewed and working satisfactory.', unique_id: '24/10/2019 11:05:55 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:05:55 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-16', Defciency_Descp: 'Vacuum toilet system port side line in operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-16', Target_Date: '2019-02-16', Action_Taken: 'Vacuum toilet line - Port side blockage rectified by flushing with water and air', unique_id: '24/10/2019 11:07:47 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:07:47 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-18', Defciency_Descp: 'Sewage overboard valve - minor leakage ( 2/3 drop/day) through the storm valve body at the Engine room bottom floor on port side', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-05-31', Action_Taken: 'Temporary measures have been taken with UW and normal steel putty and currently no sign of leakage. New valve has been ordered. In order to renew the valve plugging of Overboard line is required.Sewage overboard valve renewed at Singapore anchorage.', unique_id: '24/10/2019 11:09:56 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:09:56 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-21', Defciency_Descp: 'Main CSW pump no.1 - Discharge pressure gauge showing incorrect value', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-21', Target_Date: '2019-02-22', Action_Taken: 'Root valve for the pressure gauge renewed and line blown through - Gauge is operational.', unique_id: '24/10/2019 11:11:49 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:11:49 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-01', Defciency_Descp: 'Fresh water generator 1- Ejector pump sea water suction valve not holding, unable to isolate the pump.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-10-15', Action_Taken: 'valve Renewed', unique_id: '24/10/2019 11:38:34 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:38:34 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-02', Defciency_Descp: 'Citadel Iridium Phone displaying "SIM Card Blocked" and can\'t be used.', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-31', Target_Date: '2019-03-20', Action_Taken: 'Troubleshooting carried out with the help of IT departments. Phone is operational now.', unique_id: '24/10/2019 11:42:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:42:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-07', Defciency_Descp: 'ME Jacket pre heater steam inlet pressure gauge needle found broken.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-08', Target_Date: '2019-03-07', Action_Taken: 'Pressure gauge renewed.', unique_id: '24/10/2019 11:47:00 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:47:00 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-10', Defciency_Descp: 'ME- Aft Aux. Blower cooling fan blades found damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-03-10', Action_Taken: 'ME- Aft Aux. Blower cooling fan renewed and tested.', unique_id: '24/10/2019 11:49:58 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:49:58 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-24', Defciency_Descp: 'TG condenser –Condensate water inlet to vapour chamber pressure gauge found faulty', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-24', Target_Date: '2019-03-24', Action_Taken: 'Pressure gauge renewed.', unique_id: '25/10/2019 8:39:58 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:39:58 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-26', Defciency_Descp: 'Main Engine -Fuel oil Viscotherm is showing erratic reading.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-10', Target_Date: '2019-06-25', Action_Taken: 'Sensor received and changed. Showing viscosity correctly', unique_id: '25/10/2019 8:54:11 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:54:11 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-27', Defciency_Descp: 'Auxiliary Engine - T/C Exhaust gas inlet temperature sensor -A found faulty', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-27', Target_Date: '2019-03-28', Action_Taken: 'Sensor renewed and is operational.', unique_id: '25/10/2019 8:56:53 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:56:53 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-03-29', Defciency_Descp: 'WBT 3 (P) and WBT 5 (P) gauges showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-01', Target_Date: '2019-10-31', Action_Taken: '5P & 3P WBT sensor renewed.', unique_id: '25/10/2019 8:59:47 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:59:47 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-04-01', Defciency_Descp: 'Port windlass brake cylinder top cover seal slightly leaking', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-01', Target_Date: '2019-04-02', Action_Taken: 'Scraper ring, wear ring and rod seal renewed for top cover and tested - working satisfactory.', unique_id: '25/10/2019 9:01:57 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:01:57 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-04-16', Defciency_Descp: 'Pump Room Blower Motor Low Insulation.', PO_Ref: '', VIQ_Question_ID: 8498, VIQ_QuestionNo: '10.38', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-24', Target_Date: '2019-04-28', Action_Taken: 'Pump Room fan motor inside the terminal box one wire connection to motor winding got grounded, same replaced with new wire and motor both bearing changed with new spare, blower is operational', unique_id: '25/10/2019 9:03:51 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:03:51 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-04-28', Defciency_Descp: 'Forward whistle horn , reported not working', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-29', Target_Date: '2019-04-29', Action_Taken: 'Motor electrical connection disconnected to facilitate the repair work of the whistle. Complete unit removed from its place and taken to workshop. Dismantled the unit and found connecting rod bearing completely damaged. Same replaced with old', unique_id: '25/10/2019 9:07:39 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:07:39 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-01', Defciency_Descp: 'CONNING DISPLAY ,PROCESSOR FAN FAIL', PO_Ref: 'STAI190081', VIQ_Question_ID: 8420, VIQ_QuestionNo: '11.1', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-08-01', Action_Taken: 'processor fan replaced by CODAR technician at Singapore', unique_id: '25/10/2019 9:09:58 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:09:58 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler F.O. pump supply Mechanical seal leaking', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-31', Action_Taken: 'Mechanical Seal changed , P/P tried out satisfactory', unique_id: '25/10/2019 8:16:31 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:16:31 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Frequency controllers for MSW pumps #3 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-08-30', Action_Taken: 'FREQUENCY CONTROLLER FOR NO1 AND 2 ATTENDED ON 15/06/2019 AND NOW WORKING SATISFACTORY, As per office instructions Frequency controller not to be changed. Pump to', unique_id: '25/10/2019 11:38:10 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:38:10 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'VACUUMARATOR PUMP NO.1 END PLATE BADLY WORN OUT .', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-07', Target_Date: '2019-08-25', Action_Taken: 'Pump working satisfactory. Parts kept as spare. To be changed if issue arises', unique_id: '25/10/2019 11:41:49 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:41:49 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'IGS ECR Main control valve leaking when IG is venting to atmosphere and main blower in use', PO_Ref: 'STAI 190078', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-05', Target_Date: '2019-08-30', Action_Taken: 'Valve seat renewed. Tried out . No leakage observed', unique_id: '25/10/2019 11:45:20 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:45:20 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'GE fuel line Pr regulating v/v 9k leaking', PO_Ref: 'STAI190112', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-20', Target_Date: '2019-10-31', Action_Taken: 'Confirmed the operation during LSMGO and HFO. Found not leaking. Holdingnow. Under observation. Vessel received spare. Kept standby', unique_id: '25/10/2019 11:48:09 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:48:09 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-12', Defciency_Descp: 'Control air dryer #1 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-05', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 11:51:49 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:51:49 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'No 1 boiler burner platform has steam / leakage. Looks like same', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-24', Target_Date: '2019-05-31', Action_Taken: 'steam regulating valve. To be', unique_id: '25/10/2019 11:54:11 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:54:11 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Air bottles auto drain valve is kept shut. Same to be opened and all the crew to be advised accordingly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-22', Target_Date: '2019-05-28', Action_Taken: 'VALVES OPENED AND CREW ADVISED OF THE OPERATION', unique_id: '25/10/2019 11:56:47 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:56:47 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Area below the blower in steering Gear room needs to be cleaned.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-03', Target_Date: '2019-07-21', Action_Taken: 'Area cleaned and painted', unique_id: '25/10/2019 12:00:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 12:00:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'In steam line there is steam / water leak from dump bypass valve and air ejector steam inlet valve. To be rectified by closing main steam stop valve', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-07-21', Action_Taken: 'gasket renewed', unique_id: '25/10/2019 1:36:51 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:36:51 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Provision compressor low pressure gauge to renew', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-02', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:40:19 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:40:19 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Port side bunker manifold pressure gauge to renew, as same showing wrong indication.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:44:14 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:44:14 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'All 3 Aft winches gear case relief valve spring is missing. To replace.', PO_Ref: '', VIQ_Question_ID: 8403, VIQ_QuestionNo: '9.14', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-14', Target_Date: '2019-06-21', Action_Taken: 'Springs replaced.', unique_id: '25/10/2019 1:50:47 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:50:47 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Stbd side pump room blower motor top cover is temporarily repaired by cold work. New cover to fabricate and fit.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-06-21', Action_Taken: 'Top cover brought in E/R workshop and fabricated', unique_id: '25/10/2019 1:56:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:56:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'T/C air intake room cleaning required.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-20', Target_Date: '2019-07-21', Action_Taken: 'Gratings removed, chipped and painted.', unique_id: '25/10/2019 2:07:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:07:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'COPT#2 Oil caution remark from shore analysis', PO_Ref: '', VIQ_Question_ID: 8467, VIQ_QuestionNo: '10.7', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-12', Target_Date: '2019-06-21', Action_Taken: 'COPT NO2 OIL SUMP, DRAINED CLEANED AND OIL RENEWED', unique_id: '25/10/2019 2:09:27 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:09:27 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'Few buttons on MF/HF keypad not functioning . Also,few pins of flat cable connected to the Keypad PCB found damaged making the above mentioned keys inoperational.', PO_Ref: 'STAI195045', VIQ_Question_ID: 8340, VIQ_QuestionNo: '4.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-18', Target_Date: '2019-08-30', Action_Taken: 'MF/HF equipment flat cable renewed and tested the GMDSS found working satisfactory.', unique_id: '25/10/2019 2:12:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:12:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Soot blower # 3 of LP side is stuck. Not operating', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-29', Target_Date: '2019-06-30', Action_Taken: 'Soot Blower LP3 removed from place , soot blower was stuck badly, sealing air passage was choked completely, same made free and cleared. Soot blower fitted back in place and tried out , satisfactory', unique_id: '25/10/2019 2:15:59 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:15:59 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 13, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Clutch lining of Vacuum pump of Emergency Fire Pump came off while trying out of the pump', PO_Ref: '', VIQ_Question_ID: 8558, VIQ_QuestionNo: '5.41', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-30', Action_Taken: 'Clutch lining renewed with the spare recd , pump tried out, satisfactory', unique_id: '25/10/2019 2:18:03 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:18:03 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-29', Defciency_Descp: 'Vibscanner is not operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received new vibscanner. ', unique_id: '25/10/2019 2:21:26 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:21:26 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-01', Defciency_Descp: 'Siren for wind Hi-Hi alarm not operational and only light is working.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-02', Target_Date: '2019-10-31', Action_Taken: 'Spares received at Singapore on 31/08/2019. Wind Hi-Hi siren and light replaced. Working satsifactorily', unique_id: '25/10/2019 2:25:15 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:25:15 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'The GMT time in the BilgeGuard is 11-12 minutes behind the actual GMT time', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-30', Action_Taken: 'CHANGED 15 PPM MONITOR. NOW DIFFERENCE IS 3 MINS', unique_id: '25/10/2019 2:29:07 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:29:07 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'One of the Personal Gas Meter MSA Altair 4X (Sr no. 06028737) Showing Error message on O2, CO & H2S sensor on starting the equipment', PO_Ref: '', VIQ_Question_ID: 8540, VIQ_QuestionNo: '5.23', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-09', Target_Date: '2019-08-30', Action_Taken: 'Replaced with the new gas meter received under warranty at GOLA, US on 09th July 2019', unique_id: '25/10/2019 2:32:38 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:32:38 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'The WBT gas detection system function giving Fault 19 and 17. and is inoperable. FAULT (19) - “No custom setup, using default setup” comes and later after 15-20 seconds the FAULT(17) – “Analyzing unit no answer” shows.', PO_Ref: '', VIQ_Question_ID: 8539, VIQ_QuestionNo: '5.22', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-08', Target_Date: '2019-08-30', Action_Taken: 'Makers technician attanded vessel at GOLA, US on 08th July 2019. Troubleshooting done, necessary spares changed by technician and reconfiguration done.', unique_id: '25/10/2019 2:37:17 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:37:17 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'UTI (Sr. No. G17710) showing error message on start up indicating ‘’No msg’’.', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Tape was unwinded to check for any damage and found tape damage at 60cm mark. Continuity test was done for the UTI to confirm the tape error.As per message from office as vessel have total 4 UTIs, so this faulty UTI to be landed ashore at next', unique_id: '25/10/2019 2:40:16 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:40:16 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-16', Defciency_Descp: 'WBT 1 (P) gauge showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-02', Target_Date: '2019-10-31', Action_Taken: 'Renewed sensor on 02nd Oct 2019.', unique_id: '25/10/2019 2:42:33 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:42:33 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-21', Defciency_Descp: 'The local touch panel of WHRS( EGB) does not operate with touch, however operational with mouse', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-20', Target_Date: '2019-11-30', Action_Taken: 'The touch screen panel renewed', unique_id: '25/10/2019 2:47:46 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:47:46 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-24', Defciency_Descp: 'HFO PFR P/P NO2 MAGNETIC COUPLING CASING HOLED', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-10', Target_Date: '2019-10-31', Action_Taken: 'CHANGED CAN OF THE COUPLING', unique_id: '25/10/2019 2:56:36 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:56:36 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-29', Defciency_Descp: 'KW not matching with KWh meter reading and which leads to high SFOC, diff in % utilization of AEs.Actually KWHR is not for present KW', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-15', Target_Date: '2019-10-31', Action_Taken: 'RESET THE KWH METER. NOW SHOWING VALUES CORRECTLY', unique_id: '25/10/2019 2:59:03 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:59:03 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-06', Defciency_Descp: 'M/E F.O. leak off alarm not coming in the AMS', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-10', Target_Date: '2019-09-30', Action_Taken: 'Changed the Net DI 16. found alarm stilll there. Then found that in the tag in the AMS the switch had shifted to Man. Changed back to Auto. It is working fine. Changed it back to old NET DI16. Still it is functional.', unique_id: '25/10/2019 3:06:56 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:06:56 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-12', Defciency_Descp: 'EGB exhasut gas outlet temperature probe giving wrong readings', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-15', Target_Date: '2019-09-30', Action_Taken: 'needs replacement. Shall raise RO for same. Entered in DD defect list', unique_id: '25/10/2019 3:13:00 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:13:00 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'UTI (Sr. No. G18578) Display becomes blurred everytime after 5-10 minutes of operation', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Interchanged with the Display unit of UTI G17710 which was to be landed ashore as per message from office. Now UTI G 18578 is in good working order', unique_id: '25/10/2019 3:24:54 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:24:54 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'Work shop AC OCR under rated ,getting tripped', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-09', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:35:14 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:35:14 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'STBD life boat control circuit switch damaged', PO_Ref: '', VIQ_Question_ID: 8546, VIQ_QuestionNo: '5.29', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-15', Action_Taken: 'Requisition received at Singapore on 31/08/2019. Control circuit replaced. Working satisfactorily now.', unique_id: '25/10/2019 3:37:27 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:37:27 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'Two wire programmable TX defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-26', Target_Date: '2019-10-30', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:42:18 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:42:18 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-25', Defciency_Descp: 'Scrubber p/p mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-08', Target_Date: '2019-08-15', Action_Taken: 'Mechanical sal renewed. Pump tried out.', unique_id: '25/10/2019 3:48:02 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:48:02 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-08-08', Defciency_Descp: 'Cover for General Alarm switch on Port/Stbd boat deck broken', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-11', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:50:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:50:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-11', Defciency_Descp: 'The battery for BilgeMon 488 for OWS showing voltage 0.330 V against the required value of 2.5', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-31', Action_Taken: 'CHANGED 15 PPM SENSOR WITH NEW', unique_id: '25/10/2019 3:52:18 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:52:18 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-16', Defciency_Descp: 'Fire and GS p/p 1 mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-23', Target_Date: '2019-08-30', Action_Taken: 'Pump dismantled and overhauled, mech seal and bottom line brearing renewed', unique_id: '25/10/2019 3:57:52 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:57:52 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-07-18', Defciency_Descp: 'Stbd windlass Hydraulic brake Cylinder leaking from Cylinder top seal during anchoring operations', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-26', Target_Date: '2019-08-30', Action_Taken: 'Road seal and scrapper ring renewed. Brake tried out and found satisfactory. No further leaks observed.', unique_id: '25/10/2019 4:23:34 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 4:23:34 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-20', Defciency_Descp: 'IG 43 - deck isolation valave for the IG Line after the IG NRV was found to be leaking and not holding', PO_Ref: 'STAI190182', VIQ_Question_ID: 8593, VIQ_QuestionNo: '8.25', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-25', Target_Date: '2019-10-30', Action_Taken: 'IG 43 valve removed from location and found valve disc damaged. Valve disc was builded and put back in plce again. But still minor leak exist. RO raised for Valve disc and seat ring. Valve renewed.', unique_id: '25/10/2019 4:26:54 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 4:26:54 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler Feed water pumps motor #1 and #3 cooling Fan damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received the spare and changed the cooling fan. ', unique_id: '25/10/2019 12:03:13 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 12:03:13 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-20', Defciency_Descp: 'Kyma Engine Analyser defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-11-30', Action_Taken: 'Changed the cable connecting to computer by Technician', unique_id: '25/10/2019 2:44:53 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:44:53 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-04', Defciency_Descp: 'Anemometer- Wind speed transmitter found not working', PO_Ref: '', VIQ_Question_ID: 8326, VIQ_QuestionNo: '4.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-13', Target_Date: '2019-01-14', Action_Taken: 'Old repaired Anemometer transmitter installed. Tested and found operational.', unique_id: '24/10/2019 9:47:45 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:47:45 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-11', Defciency_Descp: 'FWD air horn non operational', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Air horn compressor and motor overhauled , fitted back and tried out, working satisfactory.', unique_id: '24/10/2019 9:52:15 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:52:15 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'IG Fan drain line in 3rd deck platform found leaking due to crack in the pipeline.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-12', Target_Date: '2019-01-12', Action_Taken: 'New pipe fabricated wid stainless steel pipe and flange . Pipe replaced with fabricated one and tested, found satisfactory.', unique_id: '24/10/2019 9:57:34 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:57:34 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'Main engine unit no.4 cyl.jacket inlet pipe leaking from flange joint.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-16', Target_Date: '2019-01-16', Action_Taken: 'Gasket replaced and boxed back with stainless steel bolts.', unique_id: '24/10/2019 9:59:53 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:59:53 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-14', Defciency_Descp: 'Hydraulic oil leakage from FWD windlass (PORT) High/Low control lever (DIRECTIONAL CONTROL VALVE)', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Both seals and o rings changed for the Directional control valve andf tested, and found working satisfactory.', unique_id: '24/10/2019 10:02:27 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:02:27 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'COPT # 2 Discharge line flange valve no.260 in pump room found traces of oil leakage.', PO_Ref: '', VIQ_Question_ID: 8615, VIQ_QuestionNo: '8.44', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-31', Target_Date: '2019-04-28', Action_Taken: 'Oil traces cleaned and flange tightened,no oil leakage', unique_id: '24/10/2019 10:06:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:06:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Stenciling of various remote sounding boxes for ballast tanks missing', PO_Ref: '', VIQ_Question_ID: 8426, VIQ_QuestionNo: '11.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-04-28', Action_Taken: 'Steciling carried out for all remote sounding boxes for ballast tanks', unique_id: '24/10/2019 10:11:45 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:11:45 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'One light in pump room 2nd deck not working.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-01-28', Action_Taken: 'Light renewed', unique_id: '24/10/2019 10:14:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:14:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Pressure regulator in air line for sea chest testing not fitted', PO_Ref: '', VIQ_Question_ID: 8351, VIQ_QuestionNo: '6.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-12', Target_Date: '2019-04-28', Action_Taken: 'Pressure regulator fitted in air line for sea chest testing.', unique_id: '24/10/2019 10:17:16 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:17:16 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Windlass pinion bearing found not greased and grease point not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-04-28', Action_Taken: 'Windlass pinion bearing greasing carried out and grease point marked.', unique_id: '24/10/2019 10:19:29 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:19:29 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Helicopter equipement CO2 extinguishers not as per requirement', PO_Ref: '', VIQ_Question_ID: 8520, VIQ_QuestionNo: '5.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-11', Target_Date: '2019-04-28', Action_Taken: 'CO2 extinguishers installed as per requirement.', unique_id: '24/10/2019 10:24:15 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:24:15 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 3 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-03', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed soon after receiving new cable.', unique_id: '24/10/2019 10:26:52 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:26:52 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'EGB bellow between LP and HP evaporator had traces of leakage, to be checked , cleaned and painted.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-17', Target_Date: '2019-04-28', Action_Taken: 'Bellow inspected, no leakes found.Bellow area cleaned and painted.', unique_id: '24/10/2019 10:29:52 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:29:52 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler outside ECR not operational. Cooler Compressor not running.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-09', Target_Date: '2019-11-15', Action_Taken: 'Leak rectified and cooler put in use', unique_id: '2019-08-11 19:41:53.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 19:41:53.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'T/C suction room door not easy to open. To ease up and grease.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-06', Target_Date: '2019-11-08', Action_Taken: 'DOOR EASED UP. ', unique_id: '2019-11-08 19:58:10.999' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 19:58:10.999' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Steering gear room door self-closing mechanism needs to adjust as door remains in open condition.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-07', Action_Taken: 'Door adjusted. ', unique_id: '2019-11-08 20:07:39.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 20:07:39.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Chlorine dosing pump of STP was running but no liquid passing. To be purged and checked regularly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-05', Target_Date: '2019-11-05', Action_Taken: 'Checked and purged. ', unique_id: '2019-08-11 20:09:57.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 20:09:57.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 16, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Drain near both aft E/R blower are choked. To be cleared.', PO_Ref: '', VIQ_Question_ID: 8349, VIQ_QuestionNo: 6.2, Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-13', Target_Date: '2019-12-05', Action_Taken: 'Drain line opened up for both blowers and cleared. ', unique_id: 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-10-31', Defciency_Descp: 'Fwd Air horn not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-11', Target_Date: '2019-11-30', Action_Taken: 'Spares received and renewed. Fog horn assembled and now in use', unique_id: 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Left over pneumatic pipe of old BWTS system in steering gear room to remove', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-10', Target_Date: '2019-11-15', Action_Taken: 'All old pneumatic pipes removed and terminated. ', unique_id: 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 4, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler in officer mess room was kept in isolated condition due to leak. TO be made operational.', PO_Ref: '', VIQ_Question_ID: 8432, VIQ_QuestionNo: 11.13, Risk_Value: 1, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-14', Target_Date: '2019-11-19', Action_Taken: 'Fountain tap leak was rectified. System back in operation. ', unique_id: 'Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Both boiler gauge glass light not working.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-15', Target_Date: '2019-11-15', Action_Taken: 'Light changed. ', unique_id: 'Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 resOfShip : ---- 2019-08-11T19:37:25.000Z mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Left over pneumatic pipe of old BWTS system in steering gear room to remove', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-10', Target_Date: '2019-11-15', Action_Taken: 'All old pneumatic pipes removed and terminated. ', unique_id: 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:53:02 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-06-21', Defciency_Descp: 'Display for OWS Bilge Mon not clear when seen from front, however can be seen at certain angle', PO_Ref: 'STAI190136', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-10-30', Action_Taken: 'Requires replacement, last changed on 29 dec 2018 , as per email correspondences , to be claimed under guarantee. ', unique_id: '25/10/2019 2:53:02 PM', Ship_ID: '48', Deficiency_Type: 'Critical Equipment', Deficiency_Cause: 'Equipment Related', Equipments: 'Critical Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:59:57 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 4, Record_Date: '2019-10-10', Defciency_Descp: 'Grey water discharge pump not taking suction.', PO_Ref: 'STAI190222', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'Pump needs overhauling ( need to change mouth ring). Raised RO. Awaiting spares', unique_id: '25/10/2019 3:59:57 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 11:58:45 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 10, Status_ID: 2, Record_Date: '2019-03-14', Defciency_Descp: 'CCTV -CAMERA NO: 2 (FWD) NOT WORKING , CAMERA NO: 3 ( FUNNEL DECK ) -ERRATIC ', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'CMERA NO : 2 (FWD - WHILE SELECTING GIVING ERROR DISPLAY ( COMPOSITE NO SYNC ) , CAMERA NO : 3 ( FUNNEL DCK ) NOT WORKING WITH DIRECT SELECTION OF NO : 3 CAMERA .WORK IN PROGRESS . OFFICE ADVISE SOUGHT ', unique_id: '24/10/2019 11:58:45 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:17:08 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 4, Record_Date: '2019-07-18', Defciency_Descp: 'APK WBT gauge showing erratic reading', PO_Ref: 'STAI190182', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'During Ballast operation at US, observed that when the tank is empty, the gauge is showing ballast tank level at 0.90 mtrs. And when the ballasting of APK was being carried out, it was not corrosponding to the relevent change in sounding of the tank. Req raised .Awaiting spares', unique_id: '25/10/2019 3:17:08 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11 09:37:39.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Mooring wires are covered with mud due to use in yard. Cleaning and greasing required.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-02-05', Action_Taken: 'All mooring wires planned for greasing in this ballast passage.', unique_id: '2019-08-11 09:37:39.000', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related,External Factors', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11 09:46:40.999 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Various tank domes of WBT and COT has rust weep marks. Derusting and painting required.', PO_Ref: '', VIQ_Question_ID: 8586, VIQ_QuestionNo: '8.18', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-01-05', Action_Taken: 'derusting planned in this ballast passage to US', unique_id: '2019-08-11 09:46:40.999', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'External Factors', Equipments: 'Deck Pipe / Fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11 10:25:48.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'All the PV valves inspection date stencil to change.', PO_Ref: '', VIQ_Question_ID: 8589, VIQ_QuestionNo: '8.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'stencilling to be done on all PV valve.', unique_id: '2019-08-11 10:25:48.000', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Deck Pipe / Fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11 10:29:34.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Outside pump room Stbd side air valve leaking, To be renewed.', PO_Ref: '', VIQ_Question_ID: 8423, VIQ_QuestionNo: '11.4', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'air manifold valve to be renewed.', unique_id: '2019-08-11 10:29:34.000', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Deck Pipe / Fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11 10:45:11.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Fire line pipe in scrubber room, just above the main power panel vibrates a lot at higher RPM. More supports to be welded. ', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'fitting of extra supports on the pipeline planned', unique_id: '2019-08-11 10:45:11.000', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'External Factors', Equipments: 'LSA / FFA', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11 19:49:28.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'MSDS and PPE to place in BWTS room for neutralizing chemicals.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-15', Action_Taken: 'To put MSDS AND PPE', unique_id: '2019-08-11 19:49:28.000', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Inappropriate Procedure', Equipments: 'Cargo Mach.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-11-08 19:51:48.999 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Various electrical insulation mat in E/R and emergency DG room are deteriorated or salt soaked. To be renewed.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-14', Action_Taken: 'TO REPLACE THE INSULATION MATS', unique_id: '2019-11-08 19:51:48.999', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Inappropriate Procedure', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-11-08 20:02:45.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Zebra stripe sticker to put in the newly installed low head pipe in ER bottom platform', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-12', Action_Taken: 'To put stripe stickers. ', unique_id: '2019-11-08 20:02:45.000', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'External Factors', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-11-08 20:13:51.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'ME LO auto filter shaft seal leaking. To be renewed', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-20', Action_Taken: 'Will be renewed in the first oppurtunity', unique_id: '2019-11-08 20:13:51.000', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Main Engine ', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11 20:17:42.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Economiser surrounding to clean and paint', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-08', Action_Taken: 'To be painted. ', unique_id: '2019-08-11 20:17:42.000', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'External Factors', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:38:50 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Main deck port side,U - Clamps on hydraulic lines, FW lines and air lines found rusted.', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-26', Target_Date: '2019-04-28', Action_Taken: 'All rusts removed and painted.', unique_id: '24/10/2019 10:38:50 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related,External Factors', Equipments: 'Deck Pipe / Fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:41:44 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'SIP\'S around the accommodation not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8425, VIQ_QuestionNo: '11.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-01', Target_Date: '2019-04-28', Action_Taken: 'SIP markings completed.', unique_id: '24/10/2019 10:41:44 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'External Factors,Human Error', Equipments: 'Hull & Tanks', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:43:36 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 6 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed.', unique_id: '24/10/2019 10:43:36 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Main Engine ', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:46:03 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Mooring wires dry and rusty not greased using wire rope greaser.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-22', Target_Date: '2019-04-28', Action_Taken: 'All mooring wires greasing carried out.', unique_id: '24/10/2019 10:46:03 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related,Human Error', Equipments: 'Deck Mach.,Mooring Mach.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:48:36 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Port MGPS CU-AL anode showing error.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-22', Target_Date: '2019-04-28', Action_Taken: 'Defective control PCB for CU and AL-Anode replaced with new spare Port MGPS is operational.', unique_id: '24/10/2019 10:48:36 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:50:32 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Dead man alarm indication light in pump room entrance not operational.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-09', Target_Date: '2019-10-31', Action_Taken: 'Received spare. Modified the switch and fitted back. It is working now.', unique_id: '24/10/2019 10:50:32 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:59:49 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-30', Defciency_Descp: 'Port Side ECDIS unit on Bridge Buzzer for alarm is not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-31', Action_Taken: 'Replaced operation circuit for ECDIS 2 (part No. OPU CCK-976 (PC640,7PCRD1796B)). Buzzer working satisfactorily.', unique_id: '24/10/2019 10:59:49 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 11:05:55 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-06', Defciency_Descp: 'Main engine # 6 unit jacket water outlet temperature reading shows erratic', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-02-06', Action_Taken: 'Temperature sensor renewed and working satisfactory.', unique_id: '24/10/2019 11:05:55 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Main Engine ', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 11:07:47 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-16', Defciency_Descp: 'Vacuum toilet system port side line in operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-16', Target_Date: '2019-02-16', Action_Taken: 'Vacuum toilet line - Port side blockage rectified by flushing with water and air', unique_id: '24/10/2019 11:07:47 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 11:09:56 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-18', Defciency_Descp: 'Sewage overboard valve - minor leakage ( 2/3 drop/day) through the storm valve body at the Engine room bottom floor on port side', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-05-31', Action_Taken: 'Temporary measures have been taken with UW and normal steel putty and currently no sign of leakage. New valve has been ordered. In order to renew the valve plugging of Overboard line is required.Sewage overboard valve renewed at Singapore anchorage.', unique_id: '24/10/2019 11:09:56 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 11:11:49 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-21', Defciency_Descp: 'Main CSW pump no.1 - Discharge pressure gauge showing incorrect value', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-21', Target_Date: '2019-02-22', Action_Taken: 'Root valve for the pressure gauge renewed and line blown through - Gauge is operational.', unique_id: '24/10/2019 11:11:49 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 11:38:34 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-01', Defciency_Descp: 'Fresh water generator 1- Ejector pump sea water suction valve not holding, unable to isolate the pump.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-10-15', Action_Taken: 'valve Renewed', unique_id: '24/10/2019 11:38:34 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 11:42:28 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-02', Defciency_Descp: 'Citadel Iridium Phone displaying "SIM Card Blocked" and can\'t be used.', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-31', Target_Date: '2019-03-20', Action_Taken: 'Troubleshooting carried out with the help of IT departments. Phone is operational now.', unique_id: '24/10/2019 11:42:28 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 11:47:00 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-07', Defciency_Descp: 'ME Jacket pre heater steam inlet pressure gauge needle found broken.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-08', Target_Date: '2019-03-07', Action_Taken: 'Pressure gauge renewed.', unique_id: '24/10/2019 11:47:00 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 11:49:58 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-10', Defciency_Descp: 'ME- Aft Aux. Blower cooling fan blades found damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-03-10', Action_Taken: 'ME- Aft Aux. Blower cooling fan renewed and tested.', unique_id: '24/10/2019 11:49:58 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Main Engine ', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 8:39:58 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-24', Defciency_Descp: 'TG condenser –Condensate water inlet to vapour chamber pressure gauge found faulty', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-24', Target_Date: '2019-03-24', Action_Taken: 'Pressure gauge renewed.', unique_id: '25/10/2019 8:39:58 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 8:54:11 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-26', Defciency_Descp: 'Main Engine -Fuel oil Viscotherm is showing erratic reading.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-10', Target_Date: '2019-06-25', Action_Taken: 'Sensor received and changed. Showing viscosity correctly', unique_id: '25/10/2019 8:54:11 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.,ER Pipes, valves & fittings', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 8:56:53 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-27', Defciency_Descp: 'Auxiliary Engine - T/C Exhaust gas inlet temperature sensor -A found faulty', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-27', Target_Date: '2019-03-28', Action_Taken: 'Sensor renewed and is operational.', unique_id: '25/10/2019 8:56:53 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Engine,Elect. Mach. & Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 8:59:47 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-03-29', Defciency_Descp: 'WBT 3 (P) and WBT 5 (P) gauges showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-01', Target_Date: '2019-10-31', Action_Taken: '5P & 3P WBT sensor renewed.', unique_id: '25/10/2019 8:59:47 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Hull & Tanks', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 9:01:57 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-04-01', Defciency_Descp: 'Port windlass brake cylinder top cover seal slightly leaking', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-01', Target_Date: '2019-04-02', Action_Taken: 'Scraper ring, wear ring and rod seal renewed for top cover and tested - working satisfactory.', unique_id: '25/10/2019 9:01:57 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Deck Mach.,Mooring Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 9:03:51 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-04-16', Defciency_Descp: 'Pump Room Blower Motor Low Insulation.', PO_Ref: '', VIQ_Question_ID: 8498, VIQ_QuestionNo: '10.38', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-24', Target_Date: '2019-04-28', Action_Taken: 'Pump Room fan motor inside the terminal box one wire connection to motor winding got grounded, same replaced with new wire and motor both bearing changed with new spare, blower is operational', unique_id: '25/10/2019 9:03:51 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Deck Mach.,Elect. Mach. & Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 9:07:39 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-04-28', Defciency_Descp: 'Forward whistle horn , reported not working', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-29', Target_Date: '2019-04-29', Action_Taken: 'Motor electrical connection disconnected to facilitate the repair work of the whistle. Complete unit removed from its place and taken to workshop. Dismantled the unit and found connecting rod bearing completely damaged. Same replaced with old', unique_id: '25/10/2019 9:07:39 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 9:09:58 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-01', Defciency_Descp: 'CONNING DISPLAY ,PROCESSOR FAN FAIL', PO_Ref: 'STAI190081', VIQ_Question_ID: 8420, VIQ_QuestionNo: '11.1', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-08-01', Action_Taken: 'processor fan replaced by CODAR technician at Singapore', unique_id: '25/10/2019 9:09:58 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.,Nav & comm. equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 8:16:31 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler F.O. pump supply Mechanical seal leaking', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-31', Action_Taken: 'Mechanical Seal changed , P/P tried out satisfactory', unique_id: '25/10/2019 8:16:31 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 11:38:10 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Frequency controllers for MSW pumps #3 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-08-30', Action_Taken: 'FREQUENCY CONTROLLER FOR NO1 AND 2 ATTENDED ON 15/06/2019 AND NOW WORKING SATISFACTORY, As per office instructions Frequency controller not to be changed. Pump to', unique_id: '25/10/2019 11:38:10 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 11:41:49 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'VACUUMARATOR PUMP NO.1 END PLATE BADLY WORN OUT .', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-07', Target_Date: '2019-08-25', Action_Taken: 'Pump working satisfactory. Parts kept as spare. To be changed if issue arises', unique_id: '25/10/2019 11:41:49 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 11:45:20 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'IGS ECR Main control valve leaking when IG is venting to atmosphere and main blower in use', PO_Ref: 'STAI 190078', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-05', Target_Date: '2019-08-30', Action_Taken: 'Valve seat renewed. Tried out . No leakage observed', unique_id: '25/10/2019 11:45:20 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Inert Gas', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 11:48:09 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'GE fuel line Pr regulating v/v 9k leaking', PO_Ref: 'STAI190112', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-20', Target_Date: '2019-10-31', Action_Taken: 'Confirmed the operation during LSMGO and HFO. Found not leaking. Holdingnow. Under observation. Vessel received spare. Kept standby', unique_id: '25/10/2019 11:48:09 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Engine', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 11:51:49 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-12', Defciency_Descp: 'Control air dryer #1 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-05', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 11:51:49 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 11:54:11 AM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'No 1 boiler burner platform has steam / leakage. Looks like same', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-24', Target_Date: '2019-05-31', Action_Taken: 'steam regulating valve. To be', unique_id: '25/10/2019 11:54:11 AM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Boiler', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 11:56:47 AM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Air bottles auto drain valve is kept shut. Same to be opened and all the crew to be advised accordingly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-22', Target_Date: '2019-05-28', Action_Taken: 'VALVES OPENED AND CREW ADVISED OF THE OPERATION', unique_id: '25/10/2019 11:56:47 AM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 12:00:28 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Area below the blower in steering Gear room needs to be cleaned.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-03', Target_Date: '2019-07-21', Action_Taken: 'Area cleaned and painted', unique_id: '25/10/2019 12:00:28 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 1:36:51 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'In steam line there is steam / water leak from dump bypass valve and air ejector steam inlet valve. To be rectified by closing main steam stop valve', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-07-21', Action_Taken: 'gasket renewed', unique_id: '25/10/2019 1:36:51 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 1:40:19 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Provision compressor low pressure gauge to renew', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-02', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:40:19 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 1:44:14 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Port side bunker manifold pressure gauge to renew, as same showing wrong indication.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:44:14 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Deck Pipe / Fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 1:50:47 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'All 3 Aft winches gear case relief valve spring is missing. To replace.', PO_Ref: '', VIQ_Question_ID: 8403, VIQ_QuestionNo: '9.14', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-14', Target_Date: '2019-06-21', Action_Taken: 'Springs replaced.', unique_id: '25/10/2019 1:50:47 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Deck Mach.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 1:56:01 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Stbd side pump room blower motor top cover is temporarily repaired by cold work. New cover to fabricate and fit.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-06-21', Action_Taken: 'Top cover brought in E/R workshop and fabricated', unique_id: '25/10/2019 1:56:01 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Deck Mach.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:07:01 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'T/C air intake room cleaning required.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-20', Target_Date: '2019-07-21', Action_Taken: 'Gratings removed, chipped and painted.', unique_id: '25/10/2019 2:07:01 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Human Error', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:09:27 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'COPT#2 Oil caution remark from shore analysis', PO_Ref: '', VIQ_Question_ID: 8467, VIQ_QuestionNo: '10.7', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-12', Target_Date: '2019-06-21', Action_Taken: 'COPT NO2 OIL SUMP, DRAINED CLEANED AND OIL RENEWED', unique_id: '25/10/2019 2:09:27 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Cargo Mach.,Deck Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:12:28 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'Few buttons on MF/HF keypad not functioning . Also,few pins of flat cable connected to the Keypad PCB found damaged making the above mentioned keys inoperational.', PO_Ref: 'STAI195045', VIQ_Question_ID: 8340, VIQ_QuestionNo: '4.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-18', Target_Date: '2019-08-30', Action_Taken: 'MF/HF equipment flat cable renewed and tested the GMDSS found working satisfactory.', unique_id: '25/10/2019 2:12:28 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Nav & comm. equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:15:59 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Soot blower # 3 of LP side is stuck. Not operating', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-29', Target_Date: '2019-06-30', Action_Taken: 'Soot Blower LP3 removed from place , soot blower was stuck badly, sealing air passage was choked completely, same made free and cleared. Soot blower fitted back in place and tried out , satisfactory', unique_id: '25/10/2019 2:15:59 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Boiler', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:18:03 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 13, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Clutch lining of Vacuum pump of Emergency Fire Pump came off while trying out of the pump', PO_Ref: '', VIQ_Question_ID: 8558, VIQ_QuestionNo: '5.41', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-30', Action_Taken: 'Clutch lining renewed with the spare recd , pump tried out, satisfactory', unique_id: '25/10/2019 2:18:03 PM', Ship_ID: '48', Deficiency_Type: 'Critical Equipment,Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Critical Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:21:26 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-29', Defciency_Descp: 'Vibscanner is not operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received new vibscanner. ', unique_id: '25/10/2019 2:21:26 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:25:15 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-01', Defciency_Descp: 'Siren for wind Hi-Hi alarm not operational and only light is working.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-02', Target_Date: '2019-10-31', Action_Taken: 'Spares received at Singapore on 31/08/2019. Wind Hi-Hi siren and light replaced. Working satsifactorily', unique_id: '25/10/2019 2:25:15 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:29:07 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'The GMT time in the BilgeGuard is 11-12 minutes behind the actual GMT time', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-30', Action_Taken: 'CHANGED 15 PPM MONITOR. NOW DIFFERENCE IS 3 MINS', unique_id: '25/10/2019 2:29:07 PM', Ship_ID: '48', Deficiency_Type: 'Critical Equipment,Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Critical Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:32:38 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'One of the Personal Gas Meter MSA Altair 4X (Sr no. 06028737) Showing Error message on O2, CO & H2S sensor on starting the equipment', PO_Ref: '', VIQ_Question_ID: 8540, VIQ_QuestionNo: '5.23', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-09', Target_Date: '2019-08-30', Action_Taken: 'Replaced with the new gas meter received under warranty at GOLA, US on 09th July 2019', unique_id: '25/10/2019 2:32:38 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'LSA / FFA', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:37:17 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'The WBT gas detection system function giving Fault 19 and 17. and is inoperable. FAULT (19) - “No custom setup, using default setup” comes and later after 15-20 seconds the FAULT(17) – “Analyzing unit no answer” shows.', PO_Ref: '', VIQ_Question_ID: 8539, VIQ_QuestionNo: '5.22', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-08', Target_Date: '2019-08-30', Action_Taken: 'Makers technician attanded vessel at GOLA, US on 08th July 2019. Troubleshooting done, necessary spares changed by technician and reconfiguration done.', unique_id: '25/10/2019 2:37:17 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Critical Equip.,Elect. Mach. & Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:40:16 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'UTI (Sr. No. G17710) showing error message on start up indicating ‘’No msg’’.', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Tape was unwinded to check for any damage and found tape damage at 60cm mark. Continuity test was done for the UTI to confirm the tape error.As per message from office as vessel have total 4 UTIs, so this faulty UTI to be landed ashore at next', unique_id: '25/10/2019 2:40:16 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:42:33 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-16', Defciency_Descp: 'WBT 1 (P) gauge showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-02', Target_Date: '2019-10-31', Action_Taken: 'Renewed sensor on 02nd Oct 2019.', unique_id: '25/10/2019 2:42:33 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:47:46 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-21', Defciency_Descp: 'The local touch panel of WHRS( EGB) does not operate with touch, however operational with mouse', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-20', Target_Date: '2019-11-30', Action_Taken: 'The touch screen panel renewed', unique_id: '25/10/2019 2:47:46 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:56:36 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-24', Defciency_Descp: 'HFO PFR P/P NO2 MAGNETIC COUPLING CASING HOLED', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-10', Target_Date: '2019-10-31', Action_Taken: 'CHANGED CAN OF THE COUPLING', unique_id: '25/10/2019 2:56:36 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Purifier', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:59:03 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-29', Defciency_Descp: 'KW not matching with KWh meter reading and which leads to high SFOC, diff in % utilization of AEs.Actually KWHR is not for present KW', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-15', Target_Date: '2019-10-31', Action_Taken: 'RESET THE KWH METER. NOW SHOWING VALUES CORRECTLY', unique_id: '25/10/2019 2:59:03 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:06:56 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-06', Defciency_Descp: 'M/E F.O. leak off alarm not coming in the AMS', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-10', Target_Date: '2019-09-30', Action_Taken: 'Changed the Net DI 16. found alarm stilll there. Then found that in the tag in the AMS the switch had shifted to Man. Changed back to Auto. It is working fine. Changed it back to old NET DI16. Still it is functional.', unique_id: '25/10/2019 3:06:56 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:13:00 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-12', Defciency_Descp: 'EGB exhasut gas outlet temperature probe giving wrong readings', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-15', Target_Date: '2019-09-30', Action_Taken: 'needs replacement. Shall raise RO for same. Entered in DD defect list', unique_id: '25/10/2019 3:13:00 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:24:54 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'UTI (Sr. No. G18578) Display becomes blurred everytime after 5-10 minutes of operation', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Interchanged with the Display unit of UTI G17710 which was to be landed ashore as per message from office. Now UTI G 18578 is in good working order', unique_id: '25/10/2019 3:24:54 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:35:14 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'Work shop AC OCR under rated ,getting tripped', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-09', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:35:14 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:37:27 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'STBD life boat control circuit switch damaged', PO_Ref: '', VIQ_Question_ID: 8546, VIQ_QuestionNo: '5.29', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-15', Action_Taken: 'Requisition received at Singapore on 31/08/2019. Control circuit replaced. Working satisfactorily now.', unique_id: '25/10/2019 3:37:27 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'LSA / FFA', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:42:18 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'Two wire programmable TX defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-26', Target_Date: '2019-10-30', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:42:18 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:48:02 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-25', Defciency_Descp: 'Scrubber p/p mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-08', Target_Date: '2019-08-15', Action_Taken: 'Mechanical sal renewed. Pump tried out.', unique_id: '25/10/2019 3:48:02 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:50:01 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-08-08', Defciency_Descp: 'Cover for General Alarm switch on Port/Stbd boat deck broken', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-11', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:50:01 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.,LSA / FFA', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:52:18 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-11', Defciency_Descp: 'The battery for BilgeMon 488 for OWS showing voltage 0.330 V against the required value of 2.5', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-31', Action_Taken: 'CHANGED 15 PPM SENSOR WITH NEW', unique_id: '25/10/2019 3:52:18 PM', Ship_ID: '48', Deficiency_Type: 'Critical Equipment', Deficiency_Cause: 'Equipment Related', Equipments: 'Critical Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 3:57:52 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-16', Defciency_Descp: 'Fire and GS p/p 1 mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-23', Target_Date: '2019-08-30', Action_Taken: 'Pump dismantled and overhauled, mech seal and bottom line brearing renewed', unique_id: '25/10/2019 3:57:52 PM', Ship_ID: '48', Deficiency_Type: 'Critical Equipment,Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Critical Equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 4:23:34 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-07-18', Defciency_Descp: 'Stbd windlass Hydraulic brake Cylinder leaking from Cylinder top seal during anchoring operations', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-26', Target_Date: '2019-08-30', Action_Taken: 'Road seal and scrapper ring renewed. Brake tried out and found satisfactory. No further leaks observed.', unique_id: '25/10/2019 4:23:34 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Mooring Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 4:26:54 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-20', Defciency_Descp: 'IG 43 - deck isolation valave for the IG Line after the IG NRV was found to be leaking and not holding', PO_Ref: 'STAI190182', VIQ_Question_ID: 8593, VIQ_QuestionNo: '8.25', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-25', Target_Date: '2019-10-30', Action_Taken: 'IG 43 valve removed from location and found valve disc damaged. Valve disc was builded and put back in plce again. But still minor leak exist. RO raised for Valve disc and seat ring. Valve renewed.', unique_id: '25/10/2019 4:26:54 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Cargo Mach.,Inert Gas', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 12:03:13 AM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler Feed water pumps motor #1 and #3 cooling Fan damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received the spare and changed the cooling fan. ', unique_id: '25/10/2019 12:03:13 AM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 25/10/2019 2:44:53 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-20', Defciency_Descp: 'Kyma Engine Analyser defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-11-30', Action_Taken: 'Changed the cable connecting to computer by Technician', unique_id: '25/10/2019 2:44:53 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 9:47:45 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-04', Defciency_Descp: 'Anemometer- Wind speed transmitter found not working', PO_Ref: '', VIQ_Question_ID: 8326, VIQ_QuestionNo: '4.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-13', Target_Date: '2019-01-14', Action_Taken: 'Old repaired Anemometer transmitter installed. Tested and found operational.', unique_id: '24/10/2019 9:47:45 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Nav & comm. equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 9:52:15 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-11', Defciency_Descp: 'FWD air horn non operational', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Air horn compressor and motor overhauled , fitted back and tried out, working satisfactory.', unique_id: '24/10/2019 9:52:15 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Nav & comm. equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 9:57:34 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'IG Fan drain line in 3rd deck platform found leaking due to crack in the pipeline.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-12', Target_Date: '2019-01-12', Action_Taken: 'New pipe fabricated wid stainless steel pipe and flange . Pipe replaced with fabricated one and tested, found satisfactory.', unique_id: '24/10/2019 9:57:34 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Inert Gas', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 9:59:53 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'Main engine unit no.4 cyl.jacket inlet pipe leaking from flange joint.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-16', Target_Date: '2019-01-16', Action_Taken: 'Gasket replaced and boxed back with stainless steel bolts.', unique_id: '24/10/2019 9:59:53 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Main Engine ', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:02:27 PM mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-14', Defciency_Descp: 'Hydraulic oil leakage from FWD windlass (PORT) High/Low control lever (DIRECTIONAL CONTROL VALVE)', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Both seals and o rings changed for the Directional control valve andf tested, and found working satisfactory.', unique_id: '24/10/2019 10:02:27 PM', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Deck Mach.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:06:01 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'COPT # 2 Discharge line flange valve no.260 in pump room found traces of oil leakage.', PO_Ref: '', VIQ_Question_ID: 8615, VIQ_QuestionNo: '8.44', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-31', Target_Date: '2019-04-28', Action_Taken: 'Oil traces cleaned and flange tightened,no oil leakage', unique_id: '24/10/2019 10:06:01 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Cargo Mach.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:11:45 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Stenciling of various remote sounding boxes for ballast tanks missing', PO_Ref: '', VIQ_Question_ID: 8426, VIQ_QuestionNo: '11.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-04-28', Action_Taken: 'Steciling carried out for all remote sounding boxes for ballast tanks', unique_id: '24/10/2019 10:11:45 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Human Error', Equipments: 'Hull & Tanks', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:14:28 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'One light in pump room 2nd deck not working.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-01-28', Action_Taken: 'Light renewed', unique_id: '24/10/2019 10:14:28 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Elect. Mach. & Equip.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:17:16 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Pressure regulator in air line for sea chest testing not fitted', PO_Ref: '', VIQ_Question_ID: 8351, VIQ_QuestionNo: '6.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-12', Target_Date: '2019-04-28', Action_Taken: 'Pressure regulator fitted in air line for sea chest testing.', unique_id: '24/10/2019 10:17:16 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related,Human Error', Equipments: 'Deck Pipe / Fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:19:29 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Windlass pinion bearing found not greased and grease point not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-04-28', Action_Taken: 'Windlass pinion bearing greasing carried out and grease point marked.', unique_id: '24/10/2019 10:19:29 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related,Human Error', Equipments: 'Deck Mach.,Mooring Mach.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:24:15 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Helicopter equipement CO2 extinguishers not as per requirement', PO_Ref: '', VIQ_Question_ID: 8520, VIQ_QuestionNo: '5.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-11', Target_Date: '2019-04-28', Action_Taken: 'CO2 extinguishers installed as per requirement.', unique_id: '24/10/2019 10:24:15 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Human Error,Knowledge Based', Equipments: 'LSA / FFA', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:26:52 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 3 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-03', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed soon after receiving new cable.', unique_id: '24/10/2019 10:26:52 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related,Inappropriate Procedure', Equipments: 'Main Engine ', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 24/10/2019 10:29:52 PM mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'EGB bellow between LP and HP evaporator had traces of leakage, to be checked , cleaned and painted.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-17', Target_Date: '2019-04-28', Action_Taken: 'Bellow inspected, no leakes found.Bellow area cleaned and painted.', unique_id: '24/10/2019 10:29:52 PM', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'ER Pipes, valves & fittings', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11 19:41:53.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler outside ECR not operational. Cooler Compressor not running.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-09', Target_Date: '2019-11-15', Action_Taken: 'Leak rectified and cooler put in use', unique_id: '2019-08-11 19:41:53.000', Ship_ID: '48', Deficiency_Type: 'Deficiency', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-11-08 19:58:10.999 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'T/C suction room door not easy to open. To ease up and grease.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-06', Target_Date: '2019-11-08', Action_Taken: 'DOOR EASED UP. ', unique_id: '2019-11-08 19:58:10.999', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-11-08 20:07:39.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Steering gear room door self-closing mechanism needs to adjust as door remains in open condition.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-07', Action_Taken: 'Door adjusted. ', unique_id: '2019-11-08 20:07:39.000', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Inappropriate Procedure', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11 20:09:57.000 mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Chlorine dosing pump of STP was running but no liquid passing. To be purged and checked regularly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-05', Target_Date: '2019-11-05', Action_Taken: 'Checked and purged. ', unique_id: '2019-08-11 20:09:57.000', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Aux. Mach.', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-11-08T10:42:57.000Z mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 16, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Drain near both aft E/R blower are choked. To be cleared.', PO_Ref: '', VIQ_Question_ID: 8349, VIQ_QuestionNo: 6.2, Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-13', Target_Date: '2019-12-05', Action_Taken: 'Drain line opened up for both blowers and cleared. ', unique_id: 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'External Factors', Equipments: 'Miscellaneous', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-03-11T07:06:56.000Z mainInsertObj { data: { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-10-31', Defciency_Descp: 'Fwd Air horn not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-11', Target_Date: '2019-11-30', Action_Taken: 'Spares received and renewed. Fog horn assembled and now in use', unique_id: 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Breakdown', Deficiency_Cause: 'Equipment Related', Equipments: 'Nav & comm. equip.', Observeration_code: 'Ship Staff' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-08-11T09:43:02.000Z mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 4, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler in officer mess room was kept in isolated condition due to leak. TO be made operational.', PO_Ref: '', VIQ_Question_ID: 8432, VIQ_QuestionNo: 11.13, Risk_Value: 1, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-14', Target_Date: '2019-11-19', Action_Taken: 'Fountain tap leak was rectified. System back in operation. ', unique_id: 'Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Accommodation ', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } resOfShip : ---- 2019-11-08T19:44:49.998Z mainInsertObj { data: { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Both boiler gauge glass light not working.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 0, Info_Sharing_Flag: 0, DryDock_Flag: 0, Completion_Date: '2019-11-15', Target_Date: '2019-11-15', Action_Taken: 'Light changed. ', unique_id: 'Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time)', Ship_ID: '48', Deficiency_Type: 'Observation', Deficiency_Cause: 'Equipment Related', Equipments: 'Boiler', Observeration_code: 'Owner / Marine / Tech. Suptd.' }, loginDetail: { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574083497, exp: 1574169897 } } OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34722, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 1 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34731, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 2 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34727, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 3 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34735, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 4 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34739, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 5 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34743, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 6 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34748, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 7 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34752, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 8 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34756, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 9 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34760, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 10 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34764, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 11 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34768, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 12 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34772, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 13 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34777, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 14 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34781, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 15 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34785, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 16 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34790, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 17 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34795, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 18 OkPacket { fieldCount: 0, affectedRows: 6, insertId: 34799, serverStatus: 2, warningCount: 3, message: '&Records: 6 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 19 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34805, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 20 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34809, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 21 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34813, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 22 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34817, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 23 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34821, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 24 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34825, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 25 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34830, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 26 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34835, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 27 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34840, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 28 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34844, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 29 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34849, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 30 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34853, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 31 OkPacket { fieldCount: 0, affectedRows: 6, insertId: 34858, serverStatus: 2, warningCount: 3, message: '&Records: 6 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 32 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34864, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 33 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34869, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 34 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34873, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 35 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34878, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 36 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34883, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 37 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34887, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 38 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34892, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 39 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34896, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 40 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34900, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 41 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34904, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 42 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34908, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 43 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34912, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 44 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34916, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 45 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34920, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 46 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34924, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 47 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34928, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 48 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34933, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 49 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34937, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 50 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34941, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 51 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34945, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 52 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34949, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 53 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34953, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 54 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34958, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 55 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34962, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 56 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34966, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 57 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34971, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 58 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34975, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 59 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34979, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 60 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34984, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 61 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 34988, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 62 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34993, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 63 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 34997, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 64 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35001, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 65 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35005, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 66 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35009, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 67 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35013, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 68 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35017, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 69 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35021, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 70 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35025, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 71 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35029, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 72 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35033, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 73 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35037, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 74 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35041, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 75 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35046, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 76 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35050, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 77 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35055, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 78 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35059, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 79 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35064, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 80 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35068, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 81 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35072, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 82 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35076, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 83 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35080, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 84 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35084, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 85 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35088, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 86 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35092, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 87 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35096, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 88 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35100, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 89 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35104, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 90 OkPacket { fieldCount: 0, affectedRows: 6, insertId: 35109, serverStatus: 2, warningCount: 3, message: '&Records: 6 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 91 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35115, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 92 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35120, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 93 OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35125, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 94 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35130, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 95 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35134, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 96 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35138, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 97 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35142, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 98 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35146, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 99 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35150, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 100 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35154, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 101 OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35158, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } incr :- 102 48 { C_Type: '', InfoSharing_Flag: 'false', InfoSharing_Flag_Change: 'false', Ship_ID: '48', Record_Date: 'null', Inspection_Type_ID: 'null', Deficiency_Type_ID: 'null', Defciency_Descp: 'null', Action_Taken: 'null', Target_Date: 'null', Completion_Date: 'null', Superident_Remarks: 'null', Status_ID: 'null', PSCRefNumbers: 'null', AreaObservation: 'null', Risk_Value: 'null', PSC_Ref_ID: 'null', Area_Observation_ID: 'null', Observeration_code: 'Ship Staff', DryDock_Flag: 'false', Critical_Item_Flag: 'false', Complete_Flag: '', currentPage: '0', itemsPerPage: '20' } 48 { C_Type: '', InfoSharing_Flag: 'false', InfoSharing_Flag_Change: 'false', Ship_ID: '48', Record_Date: 'null', Inspection_Type_ID: 'null', Deficiency_Type_ID: 'null', Defciency_Descp: 'null', Action_Taken: 'null', Target_Date: 'null', Completion_Date: 'null', Superident_Remarks: 'null', Status_ID: 'null', PSCRefNumbers: 'null', AreaObservation: 'null', Risk_Value: 'null', PSC_Ref_ID: 'null', Area_Observation_ID: 'null', DryDock_Flag: 'false', Critical_Item_Flag: 'false', Complete_Flag: '', currentPage: '0', itemsPerPage: '20' } 48 { C_Type: '', InfoSharing_Flag: 'false', InfoSharing_Flag_Change: 'false', Ship_ID: '48', Record_Date: 'null', Inspection_Type_ID: 'null', Deficiency_Type_ID: 'null', Defciency_Descp: 'null', Action_Taken: 'Spares received and renewed. Fog horn assembled and now in use', Target_Date: 'null', Completion_Date: 'null', Superident_Remarks: 'null', Status_ID: 'null', PSCRefNumbers: 'null', AreaObservation: 'null', Risk_Value: 'null', PSC_Ref_ID: 'null', Area_Observation_ID: 'null', DryDock_Flag: 'false', Critical_Item_Flag: 'false', Complete_Flag: '', currentPage: '0', itemsPerPage: '20' } SELECT ID,TYPE_OF_DEFICIENCY FROM tbl_typeof_defiency WHERE 1=1 and DELETE_FLAG = 0 ORDER BY DESCRIPTION asc SELECT ID,TITLE FROM tbl_deficiency_cause WHERE 1=1 and DELETE_FLAG = 0 ORDER BY DESCRIPTION asc SELECT ID,TITLE FROM tbl_inspection_type WHERE 1=1 and DELETE_FLAG = 0 ORDER BY DESCRIPTION asc SELECT ID,EQUIPMENT_CODES FROM tbl_equipment_codes WHERE 1=1 and DELETE_FLAG = 0 ORDER BY DESCRIPTION asc SELECT ID,TITLE FROM tbl_psc_reference_number WHERE 1=1 and DELETE_FLAG = 0 ORDER BY DESCRIPTION asc SELECT ID,MOU_NAME FROM tbl_mou_master WHERE 1=1 and DELETE_FLAG = 0 ORDER BY MOU_NAME asc SELECT ID,OBSERVER_CODES FROM tbl_observer_codes WHERE 1=1 and DELETE_FLAG = 0 ORDER BY DESCRIPTION asc SELECT ID,STATUS_CODES FROM tbl_status_codes WHERE 1=1 and DELETE_FLAG = 0 ORDER BY DESCRIPTION asc SELECT ID,TITLE FROM tbl_area_observation WHERE 1=1 and DELETE_FLAG = 0 ORDER BY DESCRIPTION asc SELECT ID,QUESTION_NUMBER,QUESTION_DESCRIPTION,RISK_PROFILE,COMPANY_RISK_PROFILE FROM tbl_questionnaire WHERE 1=1 and SIRE_FK = (SELECT ID FROM `tbl_sire` WHERE TEMPLATE_TYPE_FK = (SELECT TEMPLATE_TYPE_FK FROM tbl_vessels_master WHERE ID = 48 ) ORDER BY VERSION DESC LIMIT 1) ORDER BY QUESTION_NUMBER ASC SELECT tbl_ship_audit.ID,tbl_ship_audit.unique_id,tbl_ship_audit.Audit_Type,tbl_ship_audit.Record_Date,tbl_ship_audit.Deficiency_Type,it.TITLE as TITLE,tbl_ship_audit.Deficiency_Cause,tbl_ship_audit.Equipments,tbl_ship_audit.VIQ_QuestionNo,tbl_ship_audit.Risk_Value,tbl_ship_audit.PSC_Ref_ID,psc_ref.TITLE as PSC_Ref_TITLE,tbl_ship_audit.PSC_MOU_ID,tbl_ship_audit.Defciency_Descp,tbl_ship_audit.Observeration_code,tbl_ship_audit.Action_Taken,tbl_ship_audit.Target_Date,tbl_ship_audit.PO_Ref,sc.STATUS_CODES as STATUS_CODES,ao.TITLE as AREA_OF_OBS,tbl_ship_audit.Completion_Date,tbl_ship_audit.DryDock_Flag,tbl_ship_audit.Info_Sharing_Flag,tbl_ship_audit.Critical_Item_Flag,tbl_ship_audit.Superident_Remarks FROM tbl_ship_audit left join tbl_inspection_type it on tbl_ship_audit.Inspection_Type_ID = it.ID left join tbl_status_codes sc on tbl_ship_audit.Status_ID = sc.ID left join tbl_area_observation ao on tbl_ship_audit.Area_Observation_ID = ao.ID left join tbl_psc_reference_number psc_ref on tbl_ship_audit.PSC_Ref_ID = psc_ref.ID WHERE 1=1 and tbl_ship_audit.ACTIVE_FLAG = 1 and tbl_ship_audit.DELETE_FLAG = 0 and tbl_ship_audit.Ship_ID = 48 wb.outputAsync() jwt expired { host: 'seagraphs.com', port: 9042, path: '/call-from-company/check-subscription?', method: 'GET', headers: { token: 'eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJleHAiOjE1NDU5NTUyMDAwMDAsImVtYWlsIjoia3RAZ21haWwuY29tIiwicm9sZV9pZCI6MiwiaWQiOjQzLCJjb21wYW55X2lkIjoxOSwiaWF0IjoxNTQ1ODkzNDk2fQ.gpSLL-Zm-U3_pQe28WffoFcMlq8vzAIe5WAtfWL0BFw' } } {"status":true,"data":[{"ID":6,"USER_FK":19,"SUBSCRIPTION_START_DATE":"2019-03-01T00:00:00.000Z","SUBSCRIPTION_END_DATE":"2020-03-15T00:00:00.000Z","NUMBER_OF_SHIPS":60,"NUMBER_OF_INSPECTOR_CHECKED":9999,"SEARCHED_INSPECTOR_COUNT":53,"AMOUNT":"160","CREATED_BY":1,"CREATED_DATE":"2019-01-24T14:10:53.000Z","MODIFIED_DATE":"2019-10-30T03:08:24.000Z","MODIFIED_BY":1,"ACTIVE_FLAG":1,"DELETE_FLAG":0,"DELETE_AT":"0000-00-00 00:00:00"}] } { status: true, data: [ { ID: 6, USER_FK: 19, SUBSCRIPTION_START_DATE: '2019-03-01T00:00:00.000Z', SUBSCRIPTION_END_DATE: '2020-03-15T00:00:00.000Z', NUMBER_OF_SHIPS: 60, NUMBER_OF_INSPECTOR_CHECKED: 9999, SEARCHED_INSPECTOR_COUNT: 53, AMOUNT: '160', CREATED_BY: 1, CREATED_DATE: '2019-01-24T14:10:53.000Z', MODIFIED_DATE: '2019-10-30T03:08:24.000Z', MODIFIED_BY: 1, ACTIVE_FLAG: 1, DELETE_FLAG: 0, DELETE_AT: '0000-00-00 00:00:00' } ] } userInfo---- { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574159532, exp: 1574245932 } this is [ RowDataPacket { FIRST_NAME: 'aa', MIDDLE_NAME: 'bb', LAST_NAME: 'cc', PERMISSION: null } ] SELECT tbl_template_type.ID,tbl_template_type.TEMPLATE_TYPE,GROUP_CONCAT(s.VERSION ORDER BY s.VERSION DESC) AS vesrion,GROUP_CONCAT(s.ID ORDER BY s.VERSION DESC) AS sireFk FROM tbl_template_type left join tbl_sire s on s.TEMPLATE_TYPE_FK = tbl_template_type.ID WHERE 1=1 and tbl_template_type.DELETE_FLAG = 0 and tbl_template_type.ACTIVE_FLAG = 1 GROUP BY tbl_template_type.ID ORDER BY s.VERSION DESC SELECT tbl_fleet.ID,FLEET_NAME,group_concat(tbl_vessel_fleet_mapping.VESSEL_FK) as VESSEL_FK,group_concat(tbl_vessels_master.VESSEL_NAME) as VESSEL_NAME FROM tbl_fleet left join tbl_vessel_fleet_mapping on tbl_vessel_fleet_mapping.VESSEL_FLEET_FK = tbl_fleet.ID AND tbl_vessel_fleet_mapping.END_DATE is null left join tbl_vessels_master on tbl_vessel_fleet_mapping.VESSEL_FK = tbl_vessels_master.ID WHERE 1=1 and tbl_fleet.DELETE_FLAG = 0 and tbl_fleet.ACTIVE_FLAG = 1 GROUP BY tbl_fleet.ID SELECT ID,VESSEL_NAME,IMO_NO FROM tbl_vessels_master WHERE 1=1 and DELETE_FLAG = 0 and ACTIVE_FLAG = 1 and (VESSEL_TYPE_FK IS NULL OR (VESSEL_TYPE_FK != 0)) SELECT tbl_groups.ID,GROUP_NAME,group_concat(tbl_vessel_group_mapping.VESSEL_FK) as VESSEL_FK,group_concat(tbl_vessels_master.VESSEL_NAME) as VESSEL_NAME FROM tbl_groups left join tbl_vessel_group_mapping on tbl_vessel_group_mapping.VESSEL_GROUP_FK = tbl_groups.ID AND tbl_vessel_group_mapping.END_DATE is null left join tbl_vessels_master on tbl_vessel_group_mapping.VESSEL_FK = tbl_vessels_master.ID WHERE 1=1 and tbl_groups.DELETE_FLAG = 0 and tbl_groups.ACTIVE_FLAG = 1 GROUP BY tbl_groups.ID { start_date: '2018-07-19', end_date: '2019-11-19' } 2018-07-19 2019-11-19 {} {} ========== >=3 SELECT ID,CONCAT(COALESCE(tbl_inspector.`FNAME`,"")," ",COALESCE(tbl_inspector.`LNAME`,"")) AS FULLNAME FROM tbl_inspector WHERE 1=1 and DELETE_FLAG = 0 and ACTIVE_FLAG = 1 ORDER BY FULLNAME ASC userInfo---- { email: 'admin@proses.com', role_id: 0, username: 'admin@proses.com', id: 2, iat: 1574159532, exp: 1574245932 } this is [ RowDataPacket { FIRST_NAME: 'aa', MIDDLE_NAME: 'bb', LAST_NAME: 'cc', PERMISSION: null } ] SELECT ID,TITLE,DESCRIPTION FROM tbl_deficiency_cause WHERE 1=1 and DELETE_FLAG = 0 and ACTIVE_FLAG = 1 ORDER BY TITLE asc SELECT tbl_vessels_master.ID,concat(tbl_vessels_master.VESSEL_NAME,IF( MAX(tbl_defect_export.MODIFIED_DATE) IS NOT NULL , concat(" (",DATE_FORMAT( MAX(tbl_defect_export.MODIFIED_DATE) , "%d-%m-%Y"),")" ) ,"")) as VESSEL_NAME,concat(tbl_vessels_master.VESSEL_NAME,IF( MAX(tbl_defect_export.CREATED_DATE) IS NOT NULL , concat(" (",DATE_FORMAT( MAX(tbl_defect_export.CREATED_DATE) , "%d-%m-%Y"),")" ) ,"")) as VESSEL_NAME_WITH_EXPORTED_DATE FROM tbl_vessels_master left join tbl_defect_export on tbl_defect_export.Ship_ID = tbl_vessels_master.ID WHERE 1=1 and tbl_vessels_master.DELETE_FLAG = 0 and ACTIVE_FLAG = 1 GROUP BY tbl_vessels_master.ID SELECT ID,TITLE,DESCRIPTION FROM tbl_inspection_type WHERE 1=1 and DELETE_FLAG = 0 and ACTIVE_FLAG = 1 ORDER BY TITLE asc SELECT ID,STATUS_CODES,DESCRIPTION FROM tbl_status_codes WHERE 1=1 and DELETE_FLAG = 0 and ACTIVE_FLAG = 1 ORDER BY DESCRIPTION asc SELECT ID,EQUIPMENT_CODES,DESCRIPTION FROM tbl_equipment_codes WHERE 1=1 and DELETE_FLAG = 0 and ACTIVE_FLAG = 1 ORDER BY DESCRIPTION asc SELECT ID,TITLE,DESCRIPTION FROM tbl_area_observation WHERE 1=1 and DELETE_FLAG = 0 and ACTIVE_FLAG = 1 ORDER BY DESCRIPTION asc SELECT ID,TITLE,DESCRIPTION FROM tbl_psc_reference_number WHERE 1=1 and DELETE_FLAG = 0 and ACTIVE_FLAG = 1 ORDER BY TITLE asc SELECT ID,OBSERVER_CODES,DESCRIPTION FROM tbl_observer_codes WHERE 1=1 and DELETE_FLAG = 0 and ACTIVE_FLAG = 1 ORDER BY DESCRIPTION asc SELECT * FROM tbl_configuration WHERE 1=1 LIMIT 1 SELECT MAX(ID) as LAST_EXPORT_ID,(SELECT ID FROM `tbl_defect_export` WHERE `export_file` = '48_1574159133040.xlsm') as IMPORT_ID FROM tbl_defect_export WHERE 1=1 and Ship_ID = 48 ORDER BY ID DESC [ RowDataPacket { LAST_EXPORT_ID: 215, IMPORT_ID: 215 } ] SELECT * FROM tbl_defect_export WHERE 1=1 and Ship_ID = 48 and export_file = '48_1574159133040.xlsm' ORDER BY ID DESC ----xlData===== [ { ID: 6146, 'UNIQUE ID': '25/10/2019 2:53:02 PM', 'Date Recorded': 2019-06-21T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Display for OWS Bilge Mon not clear when seen from front, however can be seen at certain angle', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Requires replacement, last changed on 29 dec 2018 , as per email correspondences , to be claimed under guarantee. ', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': 'STAI190136', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6147, 'UNIQUE ID': '25/10/2019 3:59:57 PM', 'Date Recorded': 2019-10-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Grey water discharge pump not taking suction.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.31', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump needs overhauling ( need to change mouth ring). Raised RO. Awaiting spares', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': 'STAI190222', 'Status Code': 'Waiting spare', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6148, 'UNIQUE ID': '24/10/2019 11:58:45 PM', 'Date Recorded': 2019-03-14T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'CCTV -CAMERA NO: 2 (FWD) NOT WORKING , CAMERA NO: 3 ( FUNNEL DECK ) -ERRATIC ', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'ISPS Related', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '7.6', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CMERA NO : 2 (FWD - WHILE SELECTING GIVING ERROR DISPLAY ( COMPOSITE NO SYNC ) , CAMERA NO : 3 ( FUNNEL DCK ) NOT WORKING WITH DIRECT SELECTION OF NO : 3 CAMERA .WORK IN PROGRESS . OFFICE ADVISE SOUGHT ', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6149, 'UNIQUE ID': '25/10/2019 3:17:08 PM', 'Date Recorded': 2019-07-18T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'APK WBT gauge showing erratic reading', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.8', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'During Ballast operation at US, observed that when the tank is empty, the gauge is showing ballast tank level at 0.90 mtrs. And when the ballasting of APK was being carried out, it was not corrosponding to the relevent change in sounding of the tank. Req raised .Awaiting spares', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': 'STAI190182', 'Status Code': 'Waiting spare', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6150, 'UNIQUE ID': '2019-08-11 09:37:39.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Mooring wires are covered with mud due to use in yard. Cleaning and greasing required.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related,External Factors', 'VIQ Ref Number': '9.17', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All mooring wires planned for greasing in this ballast passage.', 'Target Date': 2020-02-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6151, 'UNIQUE ID': '2019-08-11 09:46:40.999', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Various tank domes of WBT and COT has rust weep marks. Derusting and painting required.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '8.18', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'derusting planned in this ballast passage to US', 'Target Date': 2020-01-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6152, 'UNIQUE ID': '2019-08-11 10:25:48.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'All the PV valves inspection date stencil to change.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.21', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'stencilling to be done on all PV valve.', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'In progress', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6153, 'UNIQUE ID': '2019-08-11 10:29:34.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Outside pump room Stbd side air valve leaking, To be renewed.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.4', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'air manifold valve to be renewed.', 'Target Date': 2019-11-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6154, 'UNIQUE ID': '2019-08-11 10:45:11.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Fire line pipe in scrubber room, just above the main power panel vibrates a lot at higher RPM. More supports to be welded. ', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '11.5', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'fitting of extra supports on the pipeline planned', 'Target Date': 2019-11-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6155, 'UNIQUE ID': '2019-08-11 19:49:28.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'MSDS and PPE to place in BWTS room for neutralizing chemicals.', 'Equipment Categories': 'Cargo Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Inappropriate Procedure', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'To put MSDS AND PPE', 'Target Date': 2019-11-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 6156, 'UNIQUE ID': '2019-11-08 19:51:48.999', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Various electrical insulation mat in E/R and emergency DG room are deteriorated or salt soaked. To be renewed.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Inappropriate Procedure', 'VIQ Ref Number': '11.11', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'TO REPLACE THE INSULATION MATS', 'Target Date': 2019-11-14T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'In progress', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 6157, 'UNIQUE ID': '2019-11-08 20:02:45.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Zebra stripe sticker to put in the newly installed low head pipe in ER bottom platform', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'To put stripe stickers. ', 'Target Date': 2019-11-12T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 6158, 'UNIQUE ID': '2019-11-08 20:13:51.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'ME LO auto filter shaft seal leaking. To be renewed', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Will be renewed in the first oppurtunity', 'Target Date': 2019-12-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Not Started', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 6159, 'UNIQUE ID': '2019-08-11 20:17:42.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Economiser surrounding to clean and paint', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'To be painted. ', 'Target Date': 2019-12-08T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'In progress', Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 6145, 'UNIQUE ID': 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Left over pneumatic pipe of old BWTS system in steering gear room to remove', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All old pneumatic pipes removed and terminated. ', 'Target Date': 2019-11-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 6160, 'UNIQUE ID': '24/10/2019 10:38:50 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Main deck port side,U - Clamps on hydraulic lines, FW lines and air lines found rusted.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related,External Factors', 'VIQ Ref Number': '11.5', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All rusts removed and painted.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6161, 'UNIQUE ID': '24/10/2019 10:41:44 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'SIP\'S around the accommodation not clearly marked.', 'Equipment Categories': 'Hull & Tanks', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'External Factors,Human Error', 'VIQ Ref Number': '11.6', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'SIP markings completed.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-01T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6162, 'UNIQUE ID': '24/10/2019 10:43:36 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'ME UNIT # 6 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Cable renewed.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6163, 'UNIQUE ID': '24/10/2019 10:46:03 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Mooring wires dry and rusty not greased using wire rope greaser.', 'Equipment Categories': 'Deck Mach.,Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related,Human Error', 'VIQ Ref Number': '9.17', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'All mooring wires greasing carried out.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-22T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6164, 'UNIQUE ID': '24/10/2019 10:48:36 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Port MGPS CU-AL anode showing error.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Defective control PCB for CU and AL-Anode replaced with new spare Port MGPS is operational.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-22T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6165, 'UNIQUE ID': '24/10/2019 10:50:32 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Dead man alarm indication light in pump room entrance not operational.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.11', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Received spare. Modified the switch and fitted back. It is working now.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6166, 'UNIQUE ID': '24/10/2019 10:59:49 PM', 'Date Recorded': 2019-01-30T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Port Side ECDIS unit on Bridge Buzzer for alarm is not working.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '', 'Risk Value of Obs': '', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Replaced operation circuit for ECDIS 2 (part No. OPU CCK-976 (PC640,7PCRD1796B)). Buzzer working satisfactorily.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6167, 'UNIQUE ID': '24/10/2019 11:05:55 PM', 'Date Recorded': 2019-02-06T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main engine # 6 unit jacket water outlet temperature reading shows erratic', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Temperature sensor renewed and working satisfactory.', 'Target Date': 2019-02-06T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-06T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6168, 'UNIQUE ID': '24/10/2019 11:07:47 PM', 'Date Recorded': 2019-02-16T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Vacuum toilet system port side line in operational', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Vacuum toilet line - Port side blockage rectified by flushing with water and air', 'Target Date': 2019-02-16T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-16T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6169, 'UNIQUE ID': '24/10/2019 11:09:56 PM', 'Date Recorded': 2019-02-18T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Sewage overboard valve - minor leakage ( 2/3 drop/day) through the storm valve body at the Engine room bottom floor on port side', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Temporary measures have been taken with UW and normal steel putty and currently no sign of leakage. New valve has been ordered. In order to renew the valve plugging of Overboard line is required.Sewage overboard valve renewed at Singapore anchorage.', 'Target Date': 2019-05-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-21T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6170, 'UNIQUE ID': '24/10/2019 11:11:49 PM', 'Date Recorded': 2019-02-21T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main CSW pump no.1 - Discharge pressure gauge showing incorrect value', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Root valve for the pressure gauge renewed and line blown through - Gauge is operational.', 'Target Date': 2019-02-22T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-21T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6171, 'UNIQUE ID': '24/10/2019 11:38:34 PM', 'Date Recorded': 2019-03-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Fresh water generator 1- Ejector pump sea water suction valve not holding, unable to isolate the pump.', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'valve Renewed', 'Target Date': 2019-10-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6172, 'UNIQUE ID': '24/10/2019 11:42:28 PM', 'Date Recorded': 2019-03-02T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Citadel Iridium Phone displaying "SIM Card Blocked" and can\'t be used.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '7.6', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Troubleshooting carried out with the help of IT departments. Phone is operational now.', 'Target Date': 2019-03-20T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6173, 'UNIQUE ID': '24/10/2019 11:47:00 PM', 'Date Recorded': 2019-03-07T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'ME Jacket pre heater steam inlet pressure gauge needle found broken.', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure gauge renewed.', 'Target Date': 2019-03-07T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-08T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6174, 'UNIQUE ID': '24/10/2019 11:49:58 PM', 'Date Recorded': 2019-03-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'ME- Aft Aux. Blower cooling fan blades found damaged', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'ME- Aft Aux. Blower cooling fan renewed and tested.', 'Target Date': 2019-03-10T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6175, 'UNIQUE ID': '25/10/2019 8:39:58 AM', 'Date Recorded': 2019-03-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'TG condenser –Condensate water inlet to vapour chamber pressure gauge found faulty', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure gauge renewed.', 'Target Date': 2019-03-24T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-24T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6176, 'UNIQUE ID': '25/10/2019 8:54:11 AM', 'Date Recorded': 2019-03-26T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main Engine -Fuel oil Viscotherm is showing erratic reading.', 'Equipment Categories': 'Elect. Mach. & Equip.,ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Sensor received and changed. Showing viscosity correctly', 'Target Date': 2019-06-25T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6177, 'UNIQUE ID': '25/10/2019 8:56:53 AM', 'Date Recorded': 2019-03-27T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Auxiliary Engine - T/C Exhaust gas inlet temperature sensor -A found faulty', 'Equipment Categories': 'Aux. Engine,Elect. Mach. & Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Sensor renewed and is operational.', 'Target Date': 2019-03-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-03-27T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6178, 'UNIQUE ID': '25/10/2019 8:59:47 AM', 'Date Recorded': 2019-03-29T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'WBT 3 (P) and WBT 5 (P) gauges showing erratic reading', 'Equipment Categories': 'Hull & Tanks', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.8', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': '5P & 3P WBT sensor renewed.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-01T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6179, 'UNIQUE ID': '25/10/2019 9:01:57 AM', 'Date Recorded': 2019-04-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Port windlass brake cylinder top cover seal slightly leaking', 'Equipment Categories': 'Deck Mach.,Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Scraper ring, wear ring and rod seal renewed for top cover and tested - working satisfactory.', 'Target Date': 2019-04-02T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-01T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6180, 'UNIQUE ID': '25/10/2019 9:03:51 AM', 'Date Recorded': 2019-04-16T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Pump Room Blower Motor Low Insulation.', 'Equipment Categories': 'Deck Mach.,Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.38', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump Room fan motor inside the terminal box one wire connection to motor winding got grounded, same replaced with new wire and motor both bearing changed with new spare, blower is operational', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-24T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6181, 'UNIQUE ID': '25/10/2019 9:07:39 AM', 'Date Recorded': 2019-04-28T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Forward whistle horn , reported not working', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '', 'Risk Value of Obs': '', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Motor electrical connection disconnected to facilitate the repair work of the whistle. Complete unit removed from its place and taken to workshop. Dismantled the unit and found connecting rod bearing completely damaged. Same replaced with old', 'Target Date': 2019-04-29T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-04-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6182, 'UNIQUE ID': '25/10/2019 9:09:58 AM', 'Date Recorded': 2019-05-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'CONNING DISPLAY ,PROCESSOR FAN FAIL', 'Equipment Categories': 'Aux. Mach.,Nav & comm. equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.1', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'processor fan replaced by CODAR technician at Singapore', 'Target Date': 2019-08-01T00:00:00.000Z, 'PO Ref No.': 'STAI190081', 'Status Code': 'Completed', 'Date Completed': 2019-05-21T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6183, 'UNIQUE ID': '25/10/2019 8:16:31 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Aux Boiler F.O. pump supply Mechanical seal leaking', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Mechanical Seal changed , P/P tried out satisfactory', 'Target Date': 2019-08-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6184, 'UNIQUE ID': '25/10/2019 11:38:10 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Frequency controllers for MSW pumps #3 not working', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'FREQUENCY CONTROLLER FOR NO1 AND 2 ATTENDED ON 15/06/2019 AND NOW WORKING SATISFACTORY, As per office instructions Frequency controller not to be changed. Pump to', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6185, 'UNIQUE ID': '25/10/2019 11:41:49 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'VACUUMARATOR PUMP NO.1 END PLATE BADLY WORN OUT .', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump working satisfactory. Parts kept as spare. To be changed if issue arises', 'Target Date': 2019-08-25T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6186, 'UNIQUE ID': '25/10/2019 11:45:20 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'IGS ECR Main control valve leaking when IG is venting to atmosphere and main blower in use', 'Equipment Categories': 'Inert Gas', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Valve seat renewed. Tried out . No leakage observed', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': 'STAI 190078', 'Status Code': 'Completed', 'Date Completed': 2019-08-05T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6187, 'UNIQUE ID': '25/10/2019 11:48:09 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'GE fuel line Pr regulating v/v 9k leaking', 'Equipment Categories': 'Aux. Engine', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Confirmed the operation during LSMGO and HFO. Found not leaking. Holdingnow. Under observation. Vessel received spare. Kept standby', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': 'STAI190112', 'Status Code': 'Completed', 'Date Completed': 2019-08-20T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6188, 'UNIQUE ID': '25/10/2019 11:51:49 AM', 'Date Recorded': 2019-05-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Control air dryer #1 not working', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-05T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6189, 'UNIQUE ID': '25/10/2019 11:54:11 AM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'No 1 boiler burner platform has steam / leakage. Looks like same', 'Equipment Categories': 'Boiler', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'steam regulating valve. To be', 'Target Date': 2019-05-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-24T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6190, 'UNIQUE ID': '25/10/2019 11:56:47 AM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Air bottles auto drain valve is kept shut. Same to be opened and all the crew to be advised accordingly.', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'VALVES OPENED AND CREW ADVISED OF THE OPERATION', 'Target Date': 2019-05-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-22T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6191, 'UNIQUE ID': '25/10/2019 12:00:28 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Area below the blower in steering Gear room needs to be cleaned.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.29', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Area cleaned and painted', 'Target Date': 2019-07-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6192, 'UNIQUE ID': '25/10/2019 1:36:51 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'In steam line there is steam / water leak from dump bypass valve and air ejector steam inlet valve. To be rectified by closing main steam stop valve', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'gasket renewed', 'Target Date': 2019-07-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-30T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6193, 'UNIQUE ID': '25/10/2019 1:40:19 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Provision compressor low pressure gauge to renew', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure Gauge renewed', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-02T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6194, 'UNIQUE ID': '25/10/2019 1:44:14 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Port side bunker manifold pressure gauge to renew, as same showing wrong indication.', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure Gauge renewed', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-05-30T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6195, 'UNIQUE ID': '25/10/2019 1:50:47 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'All 3 Aft winches gear case relief valve spring is missing. To replace.', 'Equipment Categories': 'Deck Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.14', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Springs replaced.', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-14T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6196, 'UNIQUE ID': '25/10/2019 1:56:01 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Stbd side pump room blower motor top cover is temporarily repaired by cold work. New cover to fabricate and fit.', 'Equipment Categories': 'Deck Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Top cover brought in E/R workshop and fabricated', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6197, 'UNIQUE ID': '25/10/2019 2:07:01 PM', 'Date Recorded': 2019-05-21T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'T/C air intake room cleaning required.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Human Error', 'VIQ Ref Number': '10.29', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Gratings removed, chipped and painted.', 'Target Date': 2019-07-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-20T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6198, 'UNIQUE ID': '25/10/2019 2:09:27 PM', 'Date Recorded': 2019-05-25T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'COPT#2 Oil caution remark from shore analysis', 'Equipment Categories': 'Cargo Mach.,Deck Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.7', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'COPT NO2 OIL SUMP, DRAINED CLEANED AND OIL RENEWED', 'Target Date': 2019-06-21T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6199, 'UNIQUE ID': '25/10/2019 2:12:28 PM', 'Date Recorded': 2019-05-25T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Few buttons on MF/HF keypad not functioning . Also,few pins of flat cable connected to the Keypad PCB found damaged making the above mentioned keys inoperational.', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '4.21', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'MF/HF equipment flat cable renewed and tested the GMDSS found working satisfactory.', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': 'STAI195045', 'Status Code': 'Completed', 'Date Completed': 2019-07-18T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6200, 'UNIQUE ID': '25/10/2019 2:15:59 PM', 'Date Recorded': 2019-05-27T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Soot blower # 3 of LP side is stuck. Not operating', 'Equipment Categories': 'Boiler', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Soot Blower LP3 removed from place , soot blower was stuck badly, sealing air passage was choked completely, same made free and cleared. Soot blower fitted back in place and tried out , satisfactory', 'Target Date': 2019-06-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-06-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6201, 'UNIQUE ID': '25/10/2019 2:18:03 PM', 'Date Recorded': 2019-05-27T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment,Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Clutch lining of Vacuum pump of Emergency Fire Pump came off while trying out of the pump', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Emgcy. Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.41', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Clutch lining renewed with the spare recd , pump tried out, satisfactory', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6202, 'UNIQUE ID': '25/10/2019 2:21:26 PM', 'Date Recorded': 2019-05-29T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Vibscanner is not operational', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Received new vibscanner. ', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6203, 'UNIQUE ID': '25/10/2019 2:25:15 PM', 'Date Recorded': 2019-06-01T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Siren for wind Hi-Hi alarm not operational and only light is working.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received at Singapore on 31/08/2019. Wind Hi-Hi siren and light replaced. Working satsifactorily', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-02T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6204, 'UNIQUE ID': '25/10/2019 2:29:07 PM', 'Date Recorded': 2019-06-11T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment,Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The GMT time in the BilgeGuard is 11-12 minutes behind the actual GMT time', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CHANGED 15 PPM MONITOR. NOW DIFFERENCE IS 3 MINS', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6205, 'UNIQUE ID': '25/10/2019 2:32:38 PM', 'Date Recorded': 2019-06-11T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'One of the Personal Gas Meter MSA Altair 4X (Sr no. 06028737) Showing Error message on O2, CO & H2S sensor on starting the equipment', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.23', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Replaced with the new gas meter received under warranty at GOLA, US on 09th July 2019', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6206, 'UNIQUE ID': '25/10/2019 2:37:17 PM', 'Date Recorded': 2019-06-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The WBT gas detection system function giving Fault 19 and 17. and is inoperable. FAULT (19) - “No custom setup, using default setup” comes and later after 15-20 seconds the FAULT(17) – “Analyzing unit no answer” shows.', 'Equipment Categories': 'Critical Equip.,Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.22', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Makers technician attanded vessel at GOLA, US on 08th July 2019. Troubleshooting done, necessary spares changed by technician and reconfiguration done.', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-07-08T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6207, 'UNIQUE ID': '25/10/2019 2:40:16 PM', 'Date Recorded': 2019-06-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'UTI (Sr. No. G17710) showing error message on start up indicating ‘’No msg’’.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.12', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Tape was unwinded to check for any damage and found tape damage at 60cm mark. Continuity test was done for the UTI to confirm the tape error.As per message from office as vessel have total 4 UTIs, so this faulty UTI to be landed ashore at next', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6208, 'UNIQUE ID': '25/10/2019 2:42:33 PM', 'Date Recorded': 2019-06-16T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'WBT 1 (P) gauge showing erratic reading', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.8', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Renewed sensor on 02nd Oct 2019.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-02T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6209, 'UNIQUE ID': '25/10/2019 2:47:46 PM', 'Date Recorded': 2019-06-21T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The local touch panel of WHRS( EGB) does not operate with touch, however operational with mouse', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'The touch screen panel renewed', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-20T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6210, 'UNIQUE ID': '25/10/2019 2:56:36 PM', 'Date Recorded': 2019-06-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'HFO PFR P/P NO2 MAGNETIC COUPLING CASING HOLED', 'Equipment Categories': 'Purifier', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CHANGED CAN OF THE COUPLING', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6211, 'UNIQUE ID': '25/10/2019 2:59:03 PM', 'Date Recorded': 2019-06-29T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'KW not matching with KWh meter reading and which leads to high SFOC, diff in % utilization of AEs.Actually KWHR is not for present KW', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'RESET THE KWH METER. NOW SHOWING VALUES CORRECTLY', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6212, 'UNIQUE ID': '25/10/2019 3:06:56 PM', 'Date Recorded': 2019-07-06T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'M/E F.O. leak off alarm not coming in the AMS', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Changed the Net DI 16. found alarm stilll there. Then found that in the tag in the AMS the switch had shifted to Man. Changed back to Auto. It is working fine. Changed it back to old NET DI16. Still it is functional.', 'Target Date': 2019-09-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-10T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6213, 'UNIQUE ID': '25/10/2019 3:13:00 PM', 'Date Recorded': 2019-07-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'EGB exhasut gas outlet temperature probe giving wrong readings', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'needs replacement. Shall raise RO for same. Entered in DD defect list', 'Target Date': 2019-09-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-15T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6214, 'UNIQUE ID': '25/10/2019 3:24:54 PM', 'Date Recorded': 2019-07-23T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'UTI (Sr. No. G18578) Display becomes blurred everytime after 5-10 minutes of operation', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.12', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Interchanged with the Display unit of UTI G17710 which was to be landed ashore as per message from office. Now UTI G 18578 is in good working order', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6215, 'UNIQUE ID': '25/10/2019 3:35:14 PM', 'Date Recorded': 2019-07-23T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Work shop AC OCR under rated ,getting tripped', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6216, 'UNIQUE ID': '25/10/2019 3:37:27 PM', 'Date Recorded': 2019-07-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'STBD life boat control circuit switch damaged', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '5.29', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Requisition received at Singapore on 31/08/2019. Control circuit replaced. Working satisfactorily now.', 'Target Date': 2019-10-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6217, 'UNIQUE ID': '25/10/2019 3:42:18 PM', 'Date Recorded': 2019-07-24T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Two wire programmable TX defective', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-09-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6218, 'UNIQUE ID': '25/10/2019 3:48:02 PM', 'Date Recorded': 2019-07-25T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Scrubber p/p mech seal leaking', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.31', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Mechanical sal renewed. Pump tried out.', 'Target Date': 2019-08-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-08T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6219, 'UNIQUE ID': '25/10/2019 3:50:01 PM', 'Date Recorded': 2019-08-08T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Cover for General Alarm switch on Port/Stbd boat deck broken', 'Equipment Categories': 'Elect. Mach. & Equip.,LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and changed. Found working satisfactory.', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6220, 'UNIQUE ID': '25/10/2019 3:52:18 PM', 'Date Recorded': 2019-08-11T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'The battery for BilgeMon 488 for OWS showing voltage 0.330 V against the required value of 2.5', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CHANGED 15 PPM SENSOR WITH NEW', 'Target Date': 2019-10-31T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6221, 'UNIQUE ID': '25/10/2019 3:57:52 PM', 'Date Recorded': 2019-08-16T00:00:00.000Z, 'Type of Deficiency': 'Critical Equipment,Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Fire and GS p/p 1 mech seal leaking', 'Equipment Categories': 'Critical Equip.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.31', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pump dismantled and overhauled, mech seal and bottom line brearing renewed', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-23T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6222, 'UNIQUE ID': '25/10/2019 4:23:34 PM', 'Date Recorded': 2019-07-18T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Stbd windlass Hydraulic brake Cylinder leaking from Cylinder top seal during anchoring operations', 'Equipment Categories': 'Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Road seal and scrapper ring renewed. Brake tried out and found satisfactory. No further leaks observed.', 'Target Date': 2019-08-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-08-26T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6223, 'UNIQUE ID': '25/10/2019 4:26:54 PM', 'Date Recorded': 2019-07-20T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'IG 43 - deck isolation valave for the IG Line after the IG NRV was found to be leaking and not holding', 'Equipment Categories': 'Cargo Mach.,Inert Gas', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.25', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'IG 43 valve removed from location and found valve disc damaged. Valve disc was builded and put back in plce again. But still minor leak exist. RO raised for Valve disc and seat ring. Valve renewed.', 'Target Date': 2019-10-30T00:00:00.000Z, 'PO Ref No.': 'STAI190182', 'Status Code': 'Completed', 'Date Completed': 2019-10-25T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6224, 'UNIQUE ID': '25/10/2019 12:03:13 AM', 'Date Recorded': 2019-05-10T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Aux Boiler Feed water pumps motor #1 and #3 cooling Fan damaged', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Received the spare and changed the cooling fan. ', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6225, 'UNIQUE ID': '25/10/2019 2:44:53 PM', 'Date Recorded': 2019-06-20T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Kyma Engine Analyser defective', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Changed the cable connecting to computer by Technician', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-10-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6226, 'UNIQUE ID': '24/10/2019 9:47:45 PM', 'Date Recorded': 2019-01-04T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Anemometer- Wind speed transmitter found not working', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '4.7', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Old repaired Anemometer transmitter installed. Tested and found operational.', 'Target Date': 2019-01-14T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-13T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6227, 'UNIQUE ID': '24/10/2019 9:52:15 PM', 'Date Recorded': 2019-01-11T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'FWD air horn non operational', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.37', 'Risk Value of Obs': 'Medium', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Air horn compressor and motor overhauled , fitted back and tried out, working satisfactory.', 'Target Date': 2019-01-18T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-18T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6228, 'UNIQUE ID': '24/10/2019 9:57:34 PM', 'Date Recorded': 2019-01-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'IG Fan drain line in 3rd deck platform found leaking due to crack in the pipeline.', 'Equipment Categories': 'Inert Gas', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'New pipe fabricated wid stainless steel pipe and flange . Pipe replaced with fabricated one and tested, found satisfactory.', 'Target Date': 2019-01-12T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6229, 'UNIQUE ID': '24/10/2019 9:59:53 PM', 'Date Recorded': 2019-01-12T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Main engine unit no.4 cyl.jacket inlet pipe leaking from flange joint.', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Gasket replaced and boxed back with stainless steel bolts.', 'Target Date': 2019-01-16T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-16T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6230, 'UNIQUE ID': '24/10/2019 10:02:27 PM', 'Date Recorded': 2019-01-14T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Hydraulic oil leakage from FWD windlass (PORT) High/Low control lever (DIRECTIONAL CONTROL VALVE)', 'Equipment Categories': 'Deck Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Both seals and o rings changed for the Directional control valve andf tested, and found working satisfactory.', 'Target Date': 2019-01-18T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-18T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6231, 'UNIQUE ID': '24/10/2019 10:06:01 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'COPT # 2 Discharge line flange valve no.260 in pump room found traces of oil leakage.', 'Equipment Categories': 'Cargo Mach.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '8.44', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Oil traces cleaned and flange tightened,no oil leakage', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-31T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6232, 'UNIQUE ID': '24/10/2019 10:11:45 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Stenciling of various remote sounding boxes for ballast tanks missing', 'Equipment Categories': 'Hull & Tanks', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'Human Error', 'VIQ Ref Number': '11.7', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Steciling carried out for all remote sounding boxes for ballast tanks', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6233, 'UNIQUE ID': '24/10/2019 10:14:28 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'One light in pump room 2nd deck not working.', 'Equipment Categories': 'Elect. Mach. & Equip.', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '11.11', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Light renewed', 'Target Date': 2019-01-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-01-29T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6234, 'UNIQUE ID': '24/10/2019 10:17:16 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Pressure regulator in air line for sea chest testing not fitted', 'Equipment Categories': 'Deck Pipe / Fittings', 'Area of Observation': 'Cargo / Ballast Systems', 'Deficiency Cause': 'Equipment Related,Human Error', 'VIQ Ref Number': '6.4', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Pressure regulator fitted in air line for sea chest testing.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-12T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6235, 'UNIQUE ID': '24/10/2019 10:19:29 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Windlass pinion bearing found not greased and grease point not clearly marked.', 'Equipment Categories': 'Deck Mach.,Mooring Mach.', 'Area of Observation': 'Mooring', 'Deficiency Cause': 'Equipment Related,Human Error', 'VIQ Ref Number': '9.2', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Windlass pinion bearing greasing carried out and grease point marked.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-06T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6236, 'UNIQUE ID': '24/10/2019 10:24:15 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Helicopter equipement CO2 extinguishers not as per requirement', 'Equipment Categories': 'LSA / FFA', 'Area of Observation': 'LSA / FFA Appliances', 'Deficiency Cause': 'Human Error,Knowledge Based', 'VIQ Ref Number': '5.4', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'CO2 extinguishers installed as per requirement.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6237, 'UNIQUE ID': '24/10/2019 10:26:52 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'ME UNIT # 3 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', 'Equipment Categories': 'Main Engine ', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related,Inappropriate Procedure', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Cable renewed soon after receiving new cable.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-03T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6238, 'UNIQUE ID': '24/10/2019 10:29:52 PM', 'Date Recorded': 2019-01-28T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'EGB bellow between LP and HP evaporator had traces of leakage, to be checked , cleaned and painted.', 'Equipment Categories': 'ER Pipes, valves & fittings', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Bellow inspected, no leakes found.Bellow area cleaned and painted.', 'Target Date': 2019-04-28T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-02-17T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6239, 'UNIQUE ID': '2019-08-11 19:41:53.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Deficiency', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Water cooler outside ECR not operational. Cooler Compressor not running.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'General Appearance', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Leak rectified and cooler put in use', 'Target Date': 2019-11-15T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-09T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6240, 'UNIQUE ID': '2019-11-08 19:58:10.999', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'T/C suction room door not easy to open. To ease up and grease.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'DOOR EASED UP. ', 'Target Date': 2019-11-08T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-06T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 6241, 'UNIQUE ID': '2019-11-08 20:07:39.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Steering gear room door self-closing mechanism needs to adjust as door remains in open condition.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Inappropriate Procedure', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Door adjusted. ', 'Target Date': 2019-11-07T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-07T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 6242, 'UNIQUE ID': '2019-08-11 20:09:57.000', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Chlorine dosing pump of STP was running but no liquid passing. To be purged and checked regularly.', 'Equipment Categories': 'Aux. Mach.', 'Area of Observation': 'Eng. / Strg. Comp.', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '10.32', 'Risk Value of Obs': 'Very High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Checked and purged. ', 'Target Date': 2019-11-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-05T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'External' }, { ID: 6243, 'UNIQUE ID': 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)', 'Date Recorded': 2019-11-05T00:00:00.000Z, 'Type of Deficiency': 'Observation', 'Observer code': 'Owner / Marine / Tech. Suptd.', 'Type of Inspection': 'Suptd. Insp.', 'Description of Deficiency': 'Drain near both aft E/R blower are choked. To be cleared.', 'Equipment Categories': 'Miscellaneous', 'Area of Observation': 'Structural Condn. / WT integrity ', 'Deficiency Cause': 'External Factors', 'VIQ Ref Number': '6.2', 'Risk Value of Obs': 'High', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Drain line opened up for both blowers and cleared. ', 'Target Date': 2019-12-05T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-13T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, { ID: 6244, 'UNIQUE ID': 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)', 'Date Recorded': 2019-10-31T00:00:00.000Z, 'Type of Deficiency': 'Breakdown', 'Observer code': 'Ship Staff', 'Type of Inspection': 'Ship Staff Insp.', 'Description of Deficiency': 'Fwd Air horn not working.', 'Equipment Categories': 'Nav & comm. equip.', 'Area of Observation': 'Navigation', 'Deficiency Cause': 'Equipment Related', 'VIQ Ref Number': '', 'Risk Value of Obs': '', 'PSC Ref Number': '', 'PSC MOU ID': '', 'Action Taken or Required': 'Spares received and renewed. Fog horn assembled and now in use', 'Target Date': 2019-11-30T00:00:00.000Z, 'PO Ref No.': '', 'Status Code': 'Completed', 'Date Completed': 2019-11-11T00:00:00.000Z, Drydock: 'No', 'Info Sharing': 'No', 'Critical Item': 'No', 'Audit Type': 'Internal' }, ... 2 more items ] updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-06-21', Defciency_Descp: 'Display for OWS Bilge Mon not clear when seen from front, however can be seen at certain angle', PO_Ref: 'STAI190136', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-10-30', Action_Taken: 'Requires replacement, last changed on 29 dec 2018 , as per email correspondences , to be claimed under guarantee. ', unique_id: '25/10/2019 2:53:02 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:53:02 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 4, Record_Date: '2019-10-10', Defciency_Descp: 'Grey water discharge pump not taking suction.', PO_Ref: 'STAI190222', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'Pump needs overhauling ( need to change mouth ring). Raised RO. Awaiting spares', unique_id: '25/10/2019 3:59:57 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:59:57 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 10, Status_ID: 2, Record_Date: '2019-03-14', Defciency_Descp: 'CCTV -CAMERA NO: 2 (FWD) NOT WORKING , CAMERA NO: 3 ( FUNNEL DECK ) -ERRATIC ', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'CMERA NO : 2 (FWD - WHILE SELECTING GIVING ERROR DISPLAY ( COMPOSITE NO SYNC ) , CAMERA NO : 3 ( FUNNEL DCK ) NOT WORKING WITH DIRECT SELECTION OF NO : 3 CAMERA .WORK IN PROGRESS . OFFICE ADVISE SOUGHT ', unique_id: '24/10/2019 11:58:45 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:58:45 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 4, Record_Date: '2019-07-18', Defciency_Descp: 'APK WBT gauge showing erratic reading', PO_Ref: 'STAI190182', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'During Ballast operation at US, observed that when the tank is empty, the gauge is showing ballast tank level at 0.90 mtrs. And when the ballasting of APK was being carried out, it was not corrosponding to the relevent change in sounding of the tank. Req raised .Awaiting spares', unique_id: '25/10/2019 3:17:08 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:17:08 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Mooring wires are covered with mud due to use in yard. Cleaning and greasing required.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-02-05', Action_Taken: 'All mooring wires planned for greasing in this ballast passage.', unique_id: '2019-08-11 09:37:39.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 09:37:39.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Various tank domes of WBT and COT has rust weep marks. Derusting and painting required.', PO_Ref: '', VIQ_Question_ID: 8586, VIQ_QuestionNo: '8.18', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-01-05', Action_Taken: 'derusting planned in this ballast passage to US', unique_id: '2019-08-11 09:46:40.999' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 09:46:40.999' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'All the PV valves inspection date stencil to change.', PO_Ref: '', VIQ_Question_ID: 8589, VIQ_QuestionNo: '8.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'stencilling to be done on all PV valve.', unique_id: '2019-08-11 10:25:48.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 10:25:48.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Outside pump room Stbd side air valve leaking, To be renewed.', PO_Ref: '', VIQ_Question_ID: 8423, VIQ_QuestionNo: '11.4', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'air manifold valve to be renewed.', unique_id: '2019-08-11 10:29:34.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 10:29:34.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Fire line pipe in scrubber room, just above the main power panel vibrates a lot at higher RPM. More supports to be welded. ', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'fitting of extra supports on the pipeline planned', unique_id: '2019-08-11 10:45:11.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 10:45:11.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'MSDS and PPE to place in BWTS room for neutralizing chemicals.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-15', Action_Taken: 'To put MSDS AND PPE', unique_id: '2019-08-11 19:49:28.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 19:49:28.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Various electrical insulation mat in E/R and emergency DG room are deteriorated or salt soaked. To be renewed.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-14', Action_Taken: 'TO REPLACE THE INSULATION MATS', unique_id: '2019-11-08 19:51:48.999' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 19:51:48.999' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Zebra stripe sticker to put in the newly installed low head pipe in ER bottom platform', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-12', Action_Taken: 'To put stripe stickers. ', unique_id: '2019-11-08 20:02:45.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 20:02:45.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'ME LO auto filter shaft seal leaking. To be renewed', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-20', Action_Taken: 'Will be renewed in the first oppurtunity', unique_id: '2019-11-08 20:13:51.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 20:13:51.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Economiser surrounding to clean and paint', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-08', Action_Taken: 'To be painted. ', unique_id: '2019-08-11 20:17:42.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 20:17:42.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Left over pneumatic pipe of old BWTS system in steering gear room to remove', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-10', Target_Date: '2019-11-15', Action_Taken: 'All old pneumatic pipes removed and terminated. ', unique_id: 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Main deck port side,U - Clamps on hydraulic lines, FW lines and air lines found rusted.', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-26', Target_Date: '2019-04-28', Action_Taken: 'All rusts removed and painted.', unique_id: '24/10/2019 10:38:50 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:38:50 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'SIP\'S around the accommodation not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8425, VIQ_QuestionNo: '11.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-01', Target_Date: '2019-04-28', Action_Taken: 'SIP markings completed.', unique_id: '24/10/2019 10:41:44 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:41:44 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 6 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed.', unique_id: '24/10/2019 10:43:36 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:43:36 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Mooring wires dry and rusty not greased using wire rope greaser.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-22', Target_Date: '2019-04-28', Action_Taken: 'All mooring wires greasing carried out.', unique_id: '24/10/2019 10:46:03 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:46:03 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Port MGPS CU-AL anode showing error.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-22', Target_Date: '2019-04-28', Action_Taken: 'Defective control PCB for CU and AL-Anode replaced with new spare Port MGPS is operational.', unique_id: '24/10/2019 10:48:36 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:48:36 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Dead man alarm indication light in pump room entrance not operational.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-09', Target_Date: '2019-10-31', Action_Taken: 'Received spare. Modified the switch and fitted back. It is working now.', unique_id: '24/10/2019 10:50:32 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:50:32 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-30', Defciency_Descp: 'Port Side ECDIS unit on Bridge Buzzer for alarm is not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-31', Action_Taken: 'Replaced operation circuit for ECDIS 2 (part No. OPU CCK-976 (PC640,7PCRD1796B)). Buzzer working satisfactorily.', unique_id: '24/10/2019 10:59:49 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:59:49 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-06', Defciency_Descp: 'Main engine # 6 unit jacket water outlet temperature reading shows erratic', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-02-06', Action_Taken: 'Temperature sensor renewed and working satisfactory.', unique_id: '24/10/2019 11:05:55 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:05:55 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-16', Defciency_Descp: 'Vacuum toilet system port side line in operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-16', Target_Date: '2019-02-16', Action_Taken: 'Vacuum toilet line - Port side blockage rectified by flushing with water and air', unique_id: '24/10/2019 11:07:47 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:07:47 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-18', Defciency_Descp: 'Sewage overboard valve - minor leakage ( 2/3 drop/day) through the storm valve body at the Engine room bottom floor on port side', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-05-31', Action_Taken: 'Temporary measures have been taken with UW and normal steel putty and currently no sign of leakage. New valve has been ordered. In order to renew the valve plugging of Overboard line is required.Sewage overboard valve renewed at Singapore anchorage.', unique_id: '24/10/2019 11:09:56 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:09:56 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-21', Defciency_Descp: 'Main CSW pump no.1 - Discharge pressure gauge showing incorrect value', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-21', Target_Date: '2019-02-22', Action_Taken: 'Root valve for the pressure gauge renewed and line blown through - Gauge is operational.', unique_id: '24/10/2019 11:11:49 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:11:49 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-01', Defciency_Descp: 'Fresh water generator 1- Ejector pump sea water suction valve not holding, unable to isolate the pump.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-10-15', Action_Taken: 'valve Renewed', unique_id: '24/10/2019 11:38:34 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:38:34 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-02', Defciency_Descp: 'Citadel Iridium Phone displaying "SIM Card Blocked" and can\'t be used.', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-31', Target_Date: '2019-03-20', Action_Taken: 'Troubleshooting carried out with the help of IT departments. Phone is operational now.', unique_id: '24/10/2019 11:42:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:42:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-07', Defciency_Descp: 'ME Jacket pre heater steam inlet pressure gauge needle found broken.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-08', Target_Date: '2019-03-07', Action_Taken: 'Pressure gauge renewed.', unique_id: '24/10/2019 11:47:00 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:47:00 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-10', Defciency_Descp: 'ME- Aft Aux. Blower cooling fan blades found damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-03-10', Action_Taken: 'ME- Aft Aux. Blower cooling fan renewed and tested.', unique_id: '24/10/2019 11:49:58 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 11:49:58 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-24', Defciency_Descp: 'TG condenser –Condensate water inlet to vapour chamber pressure gauge found faulty', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-24', Target_Date: '2019-03-24', Action_Taken: 'Pressure gauge renewed.', unique_id: '25/10/2019 8:39:58 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:39:58 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-26', Defciency_Descp: 'Main Engine -Fuel oil Viscotherm is showing erratic reading.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-10', Target_Date: '2019-06-25', Action_Taken: 'Sensor received and changed. Showing viscosity correctly', unique_id: '25/10/2019 8:54:11 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:54:11 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-27', Defciency_Descp: 'Auxiliary Engine - T/C Exhaust gas inlet temperature sensor -A found faulty', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-27', Target_Date: '2019-03-28', Action_Taken: 'Sensor renewed and is operational.', unique_id: '25/10/2019 8:56:53 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:56:53 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-03-29', Defciency_Descp: 'WBT 3 (P) and WBT 5 (P) gauges showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-01', Target_Date: '2019-10-31', Action_Taken: '5P & 3P WBT sensor renewed.', unique_id: '25/10/2019 8:59:47 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:59:47 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-04-01', Defciency_Descp: 'Port windlass brake cylinder top cover seal slightly leaking', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-01', Target_Date: '2019-04-02', Action_Taken: 'Scraper ring, wear ring and rod seal renewed for top cover and tested - working satisfactory.', unique_id: '25/10/2019 9:01:57 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:01:57 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-04-16', Defciency_Descp: 'Pump Room Blower Motor Low Insulation.', PO_Ref: '', VIQ_Question_ID: 8498, VIQ_QuestionNo: '10.38', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-24', Target_Date: '2019-04-28', Action_Taken: 'Pump Room fan motor inside the terminal box one wire connection to motor winding got grounded, same replaced with new wire and motor both bearing changed with new spare, blower is operational', unique_id: '25/10/2019 9:03:51 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:03:51 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-04-28', Defciency_Descp: 'Forward whistle horn , reported not working', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-29', Target_Date: '2019-04-29', Action_Taken: 'Motor electrical connection disconnected to facilitate the repair work of the whistle. Complete unit removed from its place and taken to workshop. Dismantled the unit and found connecting rod bearing completely damaged. Same replaced with old', unique_id: '25/10/2019 9:07:39 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:07:39 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-01', Defciency_Descp: 'CONNING DISPLAY ,PROCESSOR FAN FAIL', PO_Ref: 'STAI190081', VIQ_Question_ID: 8420, VIQ_QuestionNo: '11.1', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-08-01', Action_Taken: 'processor fan replaced by CODAR technician at Singapore', unique_id: '25/10/2019 9:09:58 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 9:09:58 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler F.O. pump supply Mechanical seal leaking', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-31', Action_Taken: 'Mechanical Seal changed , P/P tried out satisfactory', unique_id: '25/10/2019 8:16:31 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 8:16:31 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Frequency controllers for MSW pumps #3 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-08-30', Action_Taken: 'FREQUENCY CONTROLLER FOR NO1 AND 2 ATTENDED ON 15/06/2019 AND NOW WORKING SATISFACTORY, As per office instructions Frequency controller not to be changed. Pump to', unique_id: '25/10/2019 11:38:10 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:38:10 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'VACUUMARATOR PUMP NO.1 END PLATE BADLY WORN OUT .', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-07', Target_Date: '2019-08-25', Action_Taken: 'Pump working satisfactory. Parts kept as spare. To be changed if issue arises', unique_id: '25/10/2019 11:41:49 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:41:49 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'IGS ECR Main control valve leaking when IG is venting to atmosphere and main blower in use', PO_Ref: 'STAI 190078', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-05', Target_Date: '2019-08-30', Action_Taken: 'Valve seat renewed. Tried out . No leakage observed', unique_id: '25/10/2019 11:45:20 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:45:20 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'GE fuel line Pr regulating v/v 9k leaking', PO_Ref: 'STAI190112', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-20', Target_Date: '2019-10-31', Action_Taken: 'Confirmed the operation during LSMGO and HFO. Found not leaking. Holdingnow. Under observation. Vessel received spare. Kept standby', unique_id: '25/10/2019 11:48:09 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:48:09 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-12', Defciency_Descp: 'Control air dryer #1 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-05', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 11:51:49 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:51:49 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'No 1 boiler burner platform has steam / leakage. Looks like same', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-24', Target_Date: '2019-05-31', Action_Taken: 'steam regulating valve. To be', unique_id: '25/10/2019 11:54:11 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:54:11 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Air bottles auto drain valve is kept shut. Same to be opened and all the crew to be advised accordingly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-22', Target_Date: '2019-05-28', Action_Taken: 'VALVES OPENED AND CREW ADVISED OF THE OPERATION', unique_id: '25/10/2019 11:56:47 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 11:56:47 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Area below the blower in steering Gear room needs to be cleaned.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-03', Target_Date: '2019-07-21', Action_Taken: 'Area cleaned and painted', unique_id: '25/10/2019 12:00:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 12:00:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'In steam line there is steam / water leak from dump bypass valve and air ejector steam inlet valve. To be rectified by closing main steam stop valve', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-07-21', Action_Taken: 'gasket renewed', unique_id: '25/10/2019 1:36:51 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:36:51 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Provision compressor low pressure gauge to renew', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-02', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:40:19 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:40:19 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Port side bunker manifold pressure gauge to renew, as same showing wrong indication.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:44:14 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:44:14 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'All 3 Aft winches gear case relief valve spring is missing. To replace.', PO_Ref: '', VIQ_Question_ID: 8403, VIQ_QuestionNo: '9.14', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-14', Target_Date: '2019-06-21', Action_Taken: 'Springs replaced.', unique_id: '25/10/2019 1:50:47 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:50:47 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Stbd side pump room blower motor top cover is temporarily repaired by cold work. New cover to fabricate and fit.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-06-21', Action_Taken: 'Top cover brought in E/R workshop and fabricated', unique_id: '25/10/2019 1:56:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 1:56:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'T/C air intake room cleaning required.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-20', Target_Date: '2019-07-21', Action_Taken: 'Gratings removed, chipped and painted.', unique_id: '25/10/2019 2:07:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:07:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'COPT#2 Oil caution remark from shore analysis', PO_Ref: '', VIQ_Question_ID: 8467, VIQ_QuestionNo: '10.7', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-12', Target_Date: '2019-06-21', Action_Taken: 'COPT NO2 OIL SUMP, DRAINED CLEANED AND OIL RENEWED', unique_id: '25/10/2019 2:09:27 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:09:27 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'Few buttons on MF/HF keypad not functioning . Also,few pins of flat cable connected to the Keypad PCB found damaged making the above mentioned keys inoperational.', PO_Ref: 'STAI195045', VIQ_Question_ID: 8340, VIQ_QuestionNo: '4.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-18', Target_Date: '2019-08-30', Action_Taken: 'MF/HF equipment flat cable renewed and tested the GMDSS found working satisfactory.', unique_id: '25/10/2019 2:12:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:12:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Soot blower # 3 of LP side is stuck. Not operating', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-29', Target_Date: '2019-06-30', Action_Taken: 'Soot Blower LP3 removed from place , soot blower was stuck badly, sealing air passage was choked completely, same made free and cleared. Soot blower fitted back in place and tried out , satisfactory', unique_id: '25/10/2019 2:15:59 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:15:59 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 13, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Clutch lining of Vacuum pump of Emergency Fire Pump came off while trying out of the pump', PO_Ref: '', VIQ_Question_ID: 8558, VIQ_QuestionNo: '5.41', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-30', Action_Taken: 'Clutch lining renewed with the spare recd , pump tried out, satisfactory', unique_id: '25/10/2019 2:18:03 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:18:03 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-29', Defciency_Descp: 'Vibscanner is not operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received new vibscanner. ', unique_id: '25/10/2019 2:21:26 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:21:26 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-01', Defciency_Descp: 'Siren for wind Hi-Hi alarm not operational and only light is working.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-02', Target_Date: '2019-10-31', Action_Taken: 'Spares received at Singapore on 31/08/2019. Wind Hi-Hi siren and light replaced. Working satsifactorily', unique_id: '25/10/2019 2:25:15 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:25:15 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'The GMT time in the BilgeGuard is 11-12 minutes behind the actual GMT time', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-30', Action_Taken: 'CHANGED 15 PPM MONITOR. NOW DIFFERENCE IS 3 MINS', unique_id: '25/10/2019 2:29:07 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:29:07 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'One of the Personal Gas Meter MSA Altair 4X (Sr no. 06028737) Showing Error message on O2, CO & H2S sensor on starting the equipment', PO_Ref: '', VIQ_Question_ID: 8540, VIQ_QuestionNo: '5.23', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-09', Target_Date: '2019-08-30', Action_Taken: 'Replaced with the new gas meter received under warranty at GOLA, US on 09th July 2019', unique_id: '25/10/2019 2:32:38 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:32:38 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'The WBT gas detection system function giving Fault 19 and 17. and is inoperable. FAULT (19) - “No custom setup, using default setup” comes and later after 15-20 seconds the FAULT(17) – “Analyzing unit no answer” shows.', PO_Ref: '', VIQ_Question_ID: 8539, VIQ_QuestionNo: '5.22', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-08', Target_Date: '2019-08-30', Action_Taken: 'Makers technician attanded vessel at GOLA, US on 08th July 2019. Troubleshooting done, necessary spares changed by technician and reconfiguration done.', unique_id: '25/10/2019 2:37:17 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:37:17 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'UTI (Sr. No. G17710) showing error message on start up indicating ‘’No msg’’.', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Tape was unwinded to check for any damage and found tape damage at 60cm mark. Continuity test was done for the UTI to confirm the tape error.As per message from office as vessel have total 4 UTIs, so this faulty UTI to be landed ashore at next', unique_id: '25/10/2019 2:40:16 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:40:16 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-16', Defciency_Descp: 'WBT 1 (P) gauge showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-02', Target_Date: '2019-10-31', Action_Taken: 'Renewed sensor on 02nd Oct 2019.', unique_id: '25/10/2019 2:42:33 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:42:33 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-21', Defciency_Descp: 'The local touch panel of WHRS( EGB) does not operate with touch, however operational with mouse', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-20', Target_Date: '2019-11-30', Action_Taken: 'The touch screen panel renewed', unique_id: '25/10/2019 2:47:46 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:47:46 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-24', Defciency_Descp: 'HFO PFR P/P NO2 MAGNETIC COUPLING CASING HOLED', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-10', Target_Date: '2019-10-31', Action_Taken: 'CHANGED CAN OF THE COUPLING', unique_id: '25/10/2019 2:56:36 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:56:36 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-29', Defciency_Descp: 'KW not matching with KWh meter reading and which leads to high SFOC, diff in % utilization of AEs.Actually KWHR is not for present KW', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-15', Target_Date: '2019-10-31', Action_Taken: 'RESET THE KWH METER. NOW SHOWING VALUES CORRECTLY', unique_id: '25/10/2019 2:59:03 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:59:03 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-06', Defciency_Descp: 'M/E F.O. leak off alarm not coming in the AMS', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-10', Target_Date: '2019-09-30', Action_Taken: 'Changed the Net DI 16. found alarm stilll there. Then found that in the tag in the AMS the switch had shifted to Man. Changed back to Auto. It is working fine. Changed it back to old NET DI16. Still it is functional.', unique_id: '25/10/2019 3:06:56 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:06:56 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-12', Defciency_Descp: 'EGB exhasut gas outlet temperature probe giving wrong readings', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-15', Target_Date: '2019-09-30', Action_Taken: 'needs replacement. Shall raise RO for same. Entered in DD defect list', unique_id: '25/10/2019 3:13:00 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:13:00 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'UTI (Sr. No. G18578) Display becomes blurred everytime after 5-10 minutes of operation', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Interchanged with the Display unit of UTI G17710 which was to be landed ashore as per message from office. Now UTI G 18578 is in good working order', unique_id: '25/10/2019 3:24:54 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:24:54 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'Work shop AC OCR under rated ,getting tripped', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-09', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:35:14 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:35:14 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'STBD life boat control circuit switch damaged', PO_Ref: '', VIQ_Question_ID: 8546, VIQ_QuestionNo: '5.29', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-15', Action_Taken: 'Requisition received at Singapore on 31/08/2019. Control circuit replaced. Working satisfactorily now.', unique_id: '25/10/2019 3:37:27 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:37:27 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'Two wire programmable TX defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-26', Target_Date: '2019-10-30', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:42:18 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:42:18 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-25', Defciency_Descp: 'Scrubber p/p mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-08', Target_Date: '2019-08-15', Action_Taken: 'Mechanical sal renewed. Pump tried out.', unique_id: '25/10/2019 3:48:02 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:48:02 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-08-08', Defciency_Descp: 'Cover for General Alarm switch on Port/Stbd boat deck broken', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-11', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:50:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:50:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-11', Defciency_Descp: 'The battery for BilgeMon 488 for OWS showing voltage 0.330 V against the required value of 2.5', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-31', Action_Taken: 'CHANGED 15 PPM SENSOR WITH NEW', unique_id: '25/10/2019 3:52:18 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:52:18 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-16', Defciency_Descp: 'Fire and GS p/p 1 mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-23', Target_Date: '2019-08-30', Action_Taken: 'Pump dismantled and overhauled, mech seal and bottom line brearing renewed', unique_id: '25/10/2019 3:57:52 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 3:57:52 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-07-18', Defciency_Descp: 'Stbd windlass Hydraulic brake Cylinder leaking from Cylinder top seal during anchoring operations', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-26', Target_Date: '2019-08-30', Action_Taken: 'Road seal and scrapper ring renewed. Brake tried out and found satisfactory. No further leaks observed.', unique_id: '25/10/2019 4:23:34 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 4:23:34 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-20', Defciency_Descp: 'IG 43 - deck isolation valave for the IG Line after the IG NRV was found to be leaking and not holding', PO_Ref: 'STAI190182', VIQ_Question_ID: 8593, VIQ_QuestionNo: '8.25', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-25', Target_Date: '2019-10-30', Action_Taken: 'IG 43 valve removed from location and found valve disc damaged. Valve disc was builded and put back in plce again. But still minor leak exist. RO raised for Valve disc and seat ring. Valve renewed.', unique_id: '25/10/2019 4:26:54 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 4:26:54 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler Feed water pumps motor #1 and #3 cooling Fan damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received the spare and changed the cooling fan. ', unique_id: '25/10/2019 12:03:13 AM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 12:03:13 AM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-20', Defciency_Descp: 'Kyma Engine Analyser defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-11-30', Action_Taken: 'Changed the cable connecting to computer by Technician', unique_id: '25/10/2019 2:44:53 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '25/10/2019 2:44:53 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-04', Defciency_Descp: 'Anemometer- Wind speed transmitter found not working', PO_Ref: '', VIQ_Question_ID: 8326, VIQ_QuestionNo: '4.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-13', Target_Date: '2019-01-14', Action_Taken: 'Old repaired Anemometer transmitter installed. Tested and found operational.', unique_id: '24/10/2019 9:47:45 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:47:45 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-11', Defciency_Descp: 'FWD air horn non operational', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Air horn compressor and motor overhauled , fitted back and tried out, working satisfactory.', unique_id: '24/10/2019 9:52:15 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:52:15 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'IG Fan drain line in 3rd deck platform found leaking due to crack in the pipeline.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-12', Target_Date: '2019-01-12', Action_Taken: 'New pipe fabricated wid stainless steel pipe and flange . Pipe replaced with fabricated one and tested, found satisfactory.', unique_id: '24/10/2019 9:57:34 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:57:34 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'Main engine unit no.4 cyl.jacket inlet pipe leaking from flange joint.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-16', Target_Date: '2019-01-16', Action_Taken: 'Gasket replaced and boxed back with stainless steel bolts.', unique_id: '24/10/2019 9:59:53 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 9:59:53 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-14', Defciency_Descp: 'Hydraulic oil leakage from FWD windlass (PORT) High/Low control lever (DIRECTIONAL CONTROL VALVE)', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Both seals and o rings changed for the Directional control valve andf tested, and found working satisfactory.', unique_id: '24/10/2019 10:02:27 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:02:27 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'COPT # 2 Discharge line flange valve no.260 in pump room found traces of oil leakage.', PO_Ref: '', VIQ_Question_ID: 8615, VIQ_QuestionNo: '8.44', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-31', Target_Date: '2019-04-28', Action_Taken: 'Oil traces cleaned and flange tightened,no oil leakage', unique_id: '24/10/2019 10:06:01 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:06:01 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Stenciling of various remote sounding boxes for ballast tanks missing', PO_Ref: '', VIQ_Question_ID: 8426, VIQ_QuestionNo: '11.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-04-28', Action_Taken: 'Steciling carried out for all remote sounding boxes for ballast tanks', unique_id: '24/10/2019 10:11:45 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:11:45 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'One light in pump room 2nd deck not working.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-01-28', Action_Taken: 'Light renewed', unique_id: '24/10/2019 10:14:28 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:14:28 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Pressure regulator in air line for sea chest testing not fitted', PO_Ref: '', VIQ_Question_ID: 8351, VIQ_QuestionNo: '6.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-12', Target_Date: '2019-04-28', Action_Taken: 'Pressure regulator fitted in air line for sea chest testing.', unique_id: '24/10/2019 10:17:16 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:17:16 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Windlass pinion bearing found not greased and grease point not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-04-28', Action_Taken: 'Windlass pinion bearing greasing carried out and grease point marked.', unique_id: '24/10/2019 10:19:29 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:19:29 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Helicopter equipement CO2 extinguishers not as per requirement', PO_Ref: '', VIQ_Question_ID: 8520, VIQ_QuestionNo: '5.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-11', Target_Date: '2019-04-28', Action_Taken: 'CO2 extinguishers installed as per requirement.', unique_id: '24/10/2019 10:24:15 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:24:15 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 3 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-03', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed soon after receiving new cable.', unique_id: '24/10/2019 10:26:52 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:26:52 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'EGB bellow between LP and HP evaporator had traces of leakage, to be checked , cleaned and painted.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-17', Target_Date: '2019-04-28', Action_Taken: 'Bellow inspected, no leakes found.Bellow area cleaned and painted.', unique_id: '24/10/2019 10:29:52 PM' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '24/10/2019 10:29:52 PM' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler outside ECR not operational. Cooler Compressor not running.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-09', Target_Date: '2019-11-15', Action_Taken: 'Leak rectified and cooler put in use', unique_id: '2019-08-11 19:41:53.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 19:41:53.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'T/C suction room door not easy to open. To ease up and grease.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-06', Target_Date: '2019-11-08', Action_Taken: 'DOOR EASED UP. ', unique_id: '2019-11-08 19:58:10.999' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 19:58:10.999' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Steering gear room door self-closing mechanism needs to adjust as door remains in open condition.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-07', Action_Taken: 'Door adjusted. ', unique_id: '2019-11-08 20:07:39.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-11-08 20:07:39.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Chlorine dosing pump of STP was running but no liquid passing. To be purged and checked regularly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-05', Target_Date: '2019-11-05', Action_Taken: 'Checked and purged. ', unique_id: '2019-08-11 20:09:57.000' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = '2019-08-11 20:09:57.000' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 16, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Drain near both aft E/R blower are choked. To be cleared.', PO_Ref: '', VIQ_Question_ID: 8349, VIQ_QuestionNo: '6.2', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-13', Target_Date: '2019-12-05', Action_Taken: 'Drain line opened up for both blowers and cleared. ', unique_id: 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-10-31', Defciency_Descp: 'Fwd Air horn not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-11', Target_Date: '2019-11-30', Action_Taken: 'Spares received and renewed. Fog horn assembled and now in use', unique_id: 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 4, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler in officer mess room was kept in isolated condition due to leak. TO be made operational.', PO_Ref: '', VIQ_Question_ID: 8432, VIQ_QuestionNo: '11.13', Risk_Value: 1, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-14', Target_Date: '2019-11-19', Action_Taken: 'Fountain tap leak was rectified. System back in operation. ', unique_id: 'Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 updateObj : -- { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Both boiler gauge glass light not working.', PO_Ref: '-', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-15', Target_Date: '2019-11-15', Action_Taken: 'Light changed. ', unique_id: 'Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time)' } SELECT ID FROM tbl_ship_audit WHERE 1=1 and unique_id = 'Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time)' and Ship_ID = 48 resOfShip : ---- Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time) resOfShip : ---- 25/10/2019 2:53:02 PM resOfShip : ---- 25/10/2019 3:59:57 PM resOfShip : ---- 24/10/2019 11:58:45 PM resOfShip : ---- 25/10/2019 3:17:08 PM resOfShip : ---- 2019-08-11 09:37:39.000 resOfShip : ---- 2019-08-11 09:46:40.999 resOfShip : ---- 2019-08-11 10:25:48.000 resOfShip : ---- 2019-08-11 10:29:34.000 resOfShip : ---- 2019-08-11 10:45:11.000 resOfShip : ---- 2019-08-11 19:49:28.000 resOfShip : ---- 2019-11-08 19:51:48.999 resOfShip : ---- 2019-11-08 20:02:45.000 resOfShip : ---- 2019-11-08 20:13:51.000 resOfShip : ---- 2019-08-11 20:17:42.000 resOfShip : ---- Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time) resOfShip : ---- 24/10/2019 10:38:50 PM resOfShip : ---- 24/10/2019 10:41:44 PM resOfShip : ---- 24/10/2019 10:43:36 PM resOfShip : ---- 24/10/2019 10:46:03 PM resOfShip : ---- 24/10/2019 10:48:36 PM resOfShip : ---- 24/10/2019 10:50:32 PM resOfShip : ---- 24/10/2019 10:59:49 PM resOfShip : ---- 24/10/2019 11:05:55 PM resOfShip : ---- 24/10/2019 11:07:47 PM resOfShip : ---- 24/10/2019 11:09:56 PM resOfShip : ---- 24/10/2019 11:11:49 PM resOfShip : ---- 24/10/2019 11:38:34 PM resOfShip : ---- 24/10/2019 11:42:28 PM resOfShip : ---- 24/10/2019 11:47:00 PM resOfShip : ---- 24/10/2019 11:49:58 PM resOfShip : ---- 25/10/2019 8:39:58 AM resOfShip : ---- 25/10/2019 8:54:11 AM resOfShip : ---- 25/10/2019 8:56:53 AM resOfShip : ---- 25/10/2019 8:59:47 AM resOfShip : ---- 25/10/2019 9:01:57 AM resOfShip : ---- 25/10/2019 9:03:51 AM resOfShip : ---- 25/10/2019 9:07:39 AM resOfShip : ---- 25/10/2019 9:09:58 AM resOfShip : ---- 25/10/2019 8:16:31 AM resOfShip : ---- 25/10/2019 11:38:10 AM resOfShip : ---- 25/10/2019 11:41:49 AM resOfShip : ---- 25/10/2019 11:45:20 AM resOfShip : ---- 25/10/2019 11:48:09 AM resOfShip : ---- 25/10/2019 11:51:49 AM resOfShip : ---- 25/10/2019 11:54:11 AM resOfShip : ---- 25/10/2019 11:56:47 AM resOfShip : ---- 25/10/2019 12:00:28 PM resOfShip : ---- 25/10/2019 1:36:51 PM resOfShip : ---- 25/10/2019 1:40:19 PM resOfShip : ---- 25/10/2019 1:44:14 PM resOfShip : ---- 25/10/2019 1:50:47 PM resOfShip : ---- 25/10/2019 1:56:01 PM resOfShip : ---- 25/10/2019 2:07:01 PM resOfShip : ---- 25/10/2019 2:09:27 PM resOfShip : ---- 25/10/2019 2:12:28 PM resOfShip : ---- 25/10/2019 2:15:59 PM resOfShip : ---- 25/10/2019 2:18:03 PM resOfShip : ---- 25/10/2019 2:21:26 PM resOfShip : ---- 25/10/2019 2:25:15 PM resOfShip : ---- 25/10/2019 2:29:07 PM resOfShip : ---- 25/10/2019 2:32:38 PM resOfShip : ---- 25/10/2019 2:37:17 PM resOfShip : ---- 25/10/2019 2:40:16 PM resOfShip : ---- 25/10/2019 2:42:33 PM resOfShip : ---- 25/10/2019 2:47:46 PM resOfShip : ---- 25/10/2019 2:56:36 PM resOfShip : ---- 25/10/2019 2:59:03 PM resOfShip : ---- 25/10/2019 3:06:56 PM resOfShip : ---- 25/10/2019 3:13:00 PM resOfShip : ---- 25/10/2019 3:24:54 PM resOfShip : ---- 25/10/2019 3:35:14 PM resOfShip : ---- 25/10/2019 3:37:27 PM resOfShip : ---- 25/10/2019 3:42:18 PM resOfShip : ---- 25/10/2019 3:48:02 PM resOfShip : ---- 25/10/2019 3:50:01 PM resOfShip : ---- 25/10/2019 3:52:18 PM resOfShip : ---- 25/10/2019 3:57:52 PM resOfShip : ---- 25/10/2019 4:23:34 PM resOfShip : ---- 25/10/2019 4:26:54 PM resOfShip : ---- 25/10/2019 12:03:13 AM resOfShip : ---- 25/10/2019 2:44:53 PM resOfShip : ---- 24/10/2019 9:47:45 PM resOfShip : ---- 24/10/2019 9:52:15 PM resOfShip : ---- 24/10/2019 9:57:34 PM resOfShip : ---- 24/10/2019 9:59:53 PM resOfShip : ---- 24/10/2019 10:02:27 PM resOfShip : ---- 24/10/2019 10:06:01 PM resOfShip : ---- 24/10/2019 10:11:45 PM resOfShip : ---- 24/10/2019 10:14:28 PM resOfShip : ---- 24/10/2019 10:17:16 PM resOfShip : ---- 24/10/2019 10:19:29 PM resOfShip : ---- 24/10/2019 10:24:15 PM resOfShip : ---- 24/10/2019 10:26:52 PM resOfShip : ---- 24/10/2019 10:29:52 PM resOfShip : ---- 2019-08-11 19:41:53.000 resOfShip : ---- 2019-11-08 19:58:10.999 resOfShip : ---- 2019-11-08 20:07:39.000 resOfShip : ---- 2019-08-11 20:09:57.000 resOfShip : ---- Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time) resOfShip : ---- Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time) resOfShip : ---- Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time) deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-10-31', Defciency_Descp: 'Fwd Air horn not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-11', Target_Date: '2019-11-30', Action_Taken: 'Spares received and renewed. Fog horn assembled and now in use', unique_id: 'Mon Mar 11 2019 07:06:56 GMT+0000 (Coordinated Universal Time)' } deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-06-21', Defciency_Descp: 'Display for OWS Bilge Mon not clear when seen from front, however can be seen at certain angle', PO_Ref: 'STAI190136', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-10-30', Action_Taken: 'Requires replacement, last changed on 29 dec 2018 , as per email correspondences , to be claimed under guarantee. ', unique_id: '25/10/2019 2:53:02 PM' } deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 4, Record_Date: '2019-10-10', Defciency_Descp: 'Grey water discharge pump not taking suction.', PO_Ref: 'STAI190222', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'Pump needs overhauling ( need to change mouth ring). Raised RO. Awaiting spares', unique_id: '25/10/2019 3:59:57 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35162, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35166, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35170, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 10, Status_ID: 2, Record_Date: '2019-03-14', Defciency_Descp: 'CCTV -CAMERA NO: 2 (FWD) NOT WORKING , CAMERA NO: 3 ( FUNNEL DECK ) -ERRATIC ', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'CMERA NO : 2 (FWD - WHILE SELECTING GIVING ERROR DISPLAY ( COMPOSITE NO SYNC ) , CAMERA NO : 3 ( FUNNEL DCK ) NOT WORKING WITH DIRECT SELECTION OF NO : 3 CAMERA .WORK IN PROGRESS . OFFICE ADVISE SOUGHT ', unique_id: '24/10/2019 11:58:45 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35174, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 4, Record_Date: '2019-07-18', Defciency_Descp: 'APK WBT gauge showing erratic reading', PO_Ref: 'STAI190182', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'During Ballast operation at US, observed that when the tank is empty, the gauge is showing ballast tank level at 0.90 mtrs. And when the ballasting of APK was being carried out, it was not corrosponding to the relevent change in sounding of the tank. Req raised .Awaiting spares', unique_id: '25/10/2019 3:17:08 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35178, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Mooring wires are covered with mud due to use in yard. Cleaning and greasing required.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-02-05', Action_Taken: 'All mooring wires planned for greasing in this ballast passage.', unique_id: '2019-08-11 09:37:39.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35182, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Various tank domes of WBT and COT has rust weep marks. Derusting and painting required.', PO_Ref: '', VIQ_Question_ID: 8586, VIQ_QuestionNo: '8.18', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2020-01-05', Action_Taken: 'derusting planned in this ballast passage to US', unique_id: '2019-08-11 09:46:40.999' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35187, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'All the PV valves inspection date stencil to change.', PO_Ref: '', VIQ_Question_ID: 8589, VIQ_QuestionNo: '8.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-30', Action_Taken: 'stencilling to be done on all PV valve.', unique_id: '2019-08-11 10:25:48.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35191, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Outside pump room Stbd side air valve leaking, To be renewed.', PO_Ref: '', VIQ_Question_ID: 8423, VIQ_QuestionNo: '11.4', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'air manifold valve to be renewed.', unique_id: '2019-08-11 10:29:34.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35195, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Fire line pipe in scrubber room, just above the main power panel vibrates a lot at higher RPM. More supports to be welded. ', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-20', Action_Taken: 'fitting of extra supports on the pipeline planned', unique_id: '2019-08-11 10:45:11.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35199, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'MSDS and PPE to place in BWTS room for neutralizing chemicals.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-15', Action_Taken: 'To put MSDS AND PPE', unique_id: '2019-08-11 19:49:28.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35203, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Various electrical insulation mat in E/R and emergency DG room are deteriorated or salt soaked. To be renewed.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-14', Action_Taken: 'TO REPLACE THE INSULATION MATS', unique_id: '2019-11-08 19:51:48.999' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35207, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'Zebra stripe sticker to put in the newly installed low head pipe in ER bottom platform', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-11-12', Action_Taken: 'To put stripe stickers. ', unique_id: '2019-11-08 20:02:45.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35211, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 2, Record_Date: '2019-11-05', Defciency_Descp: 'ME LO auto filter shaft seal leaking. To be renewed', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-20', Action_Taken: 'Will be renewed in the first oppurtunity', unique_id: '2019-11-08 20:13:51.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35216, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 3, Record_Date: '2019-11-05', Defciency_Descp: 'Economiser surrounding to clean and paint', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: null, Target_Date: '2019-12-08', Action_Taken: 'To be painted. ', unique_id: '2019-08-11 20:17:42.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35220, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Left over pneumatic pipe of old BWTS system in steering gear room to remove', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-10', Target_Date: '2019-11-15', Action_Taken: 'All old pneumatic pipes removed and terminated. ', unique_id: 'Sun Aug 11 2019 19:37:25 GMT+0000 (Coordinated Universal Time)' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35224, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Main deck port side,U - Clamps on hydraulic lines, FW lines and air lines found rusted.', PO_Ref: '', VIQ_Question_ID: 8424, VIQ_QuestionNo: '11.5', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-26', Target_Date: '2019-04-28', Action_Taken: 'All rusts removed and painted.', unique_id: '24/10/2019 10:38:50 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35229, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'SIP\'S around the accommodation not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8425, VIQ_QuestionNo: '11.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-01', Target_Date: '2019-04-28', Action_Taken: 'SIP markings completed.', unique_id: '24/10/2019 10:41:44 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35234, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 6 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed.', unique_id: '24/10/2019 10:43:36 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35239, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 6, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Mooring wires dry and rusty not greased using wire rope greaser.', PO_Ref: '', VIQ_Question_ID: 8406, VIQ_QuestionNo: '9.17', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-22', Target_Date: '2019-04-28', Action_Taken: 'All mooring wires greasing carried out.', unique_id: '24/10/2019 10:46:03 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 6, insertId: 35243, serverStatus: 2, warningCount: 3, message: '&Records: 6 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Port MGPS CU-AL anode showing error.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-22', Target_Date: '2019-04-28', Action_Taken: 'Defective control PCB for CU and AL-Anode replaced with new spare Port MGPS is operational.', unique_id: '24/10/2019 10:48:36 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35249, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Dead man alarm indication light in pump room entrance not operational.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-09', Target_Date: '2019-10-31', Action_Taken: 'Received spare. Modified the switch and fitted back. It is working now.', unique_id: '24/10/2019 10:50:32 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35253, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-30', Defciency_Descp: 'Port Side ECDIS unit on Bridge Buzzer for alarm is not working.', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-31', Action_Taken: 'Replaced operation circuit for ECDIS 2 (part No. OPU CCK-976 (PC640,7PCRD1796B)). Buzzer working satisfactorily.', unique_id: '24/10/2019 10:59:49 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35257, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-06', Defciency_Descp: 'Main engine # 6 unit jacket water outlet temperature reading shows erratic', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-02-06', Action_Taken: 'Temperature sensor renewed and working satisfactory.', unique_id: '24/10/2019 11:05:55 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35261, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-16', Defciency_Descp: 'Vacuum toilet system port side line in operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-16', Target_Date: '2019-02-16', Action_Taken: 'Vacuum toilet line - Port side blockage rectified by flushing with water and air', unique_id: '24/10/2019 11:07:47 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35265, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-18', Defciency_Descp: 'Sewage overboard valve - minor leakage ( 2/3 drop/day) through the storm valve body at the Engine room bottom floor on port side', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-05-31', Action_Taken: 'Temporary measures have been taken with UW and normal steel putty and currently no sign of leakage. New valve has been ordered. In order to renew the valve plugging of Overboard line is required.Sewage overboard valve renewed at Singapore anchorage.', unique_id: '24/10/2019 11:09:56 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35269, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-02-21', Defciency_Descp: 'Main CSW pump no.1 - Discharge pressure gauge showing incorrect value', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-21', Target_Date: '2019-02-22', Action_Taken: 'Root valve for the pressure gauge renewed and line blown through - Gauge is operational.', unique_id: '24/10/2019 11:11:49 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35274, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-01', Defciency_Descp: 'Fresh water generator 1- Ejector pump sea water suction valve not holding, unable to isolate the pump.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-10-15', Action_Taken: 'valve Renewed', unique_id: '24/10/2019 11:38:34 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35279, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-02', Defciency_Descp: 'Citadel Iridium Phone displaying "SIM Card Blocked" and can\'t be used.', PO_Ref: '', VIQ_Question_ID: 8376, VIQ_QuestionNo: '7.6', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-31', Target_Date: '2019-03-20', Action_Taken: 'Troubleshooting carried out with the help of IT departments. Phone is operational now.', unique_id: '24/10/2019 11:42:28 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35284, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-07', Defciency_Descp: 'ME Jacket pre heater steam inlet pressure gauge needle found broken.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-08', Target_Date: '2019-03-07', Action_Taken: 'Pressure gauge renewed.', unique_id: '24/10/2019 11:47:00 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35288, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-10', Defciency_Descp: 'ME- Aft Aux. Blower cooling fan blades found damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-11', Target_Date: '2019-03-10', Action_Taken: 'ME- Aft Aux. Blower cooling fan renewed and tested.', unique_id: '24/10/2019 11:49:58 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35293, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-24', Defciency_Descp: 'TG condenser –Condensate water inlet to vapour chamber pressure gauge found faulty', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-24', Target_Date: '2019-03-24', Action_Taken: 'Pressure gauge renewed.', unique_id: '25/10/2019 8:39:58 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35297, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 6, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-26', Defciency_Descp: 'Main Engine -Fuel oil Viscotherm is showing erratic reading.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-10', Target_Date: '2019-06-25', Action_Taken: 'Sensor received and changed. Showing viscosity correctly', unique_id: '25/10/2019 8:54:11 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 6, insertId: 35302, serverStatus: 2, warningCount: 3, message: '&Records: 6 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-03-27', Defciency_Descp: 'Auxiliary Engine - T/C Exhaust gas inlet temperature sensor -A found faulty', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-03-27', Target_Date: '2019-03-28', Action_Taken: 'Sensor renewed and is operational.', unique_id: '25/10/2019 8:56:53 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35308, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-03-29', Defciency_Descp: 'WBT 3 (P) and WBT 5 (P) gauges showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-01', Target_Date: '2019-10-31', Action_Taken: '5P & 3P WBT sensor renewed.', unique_id: '25/10/2019 8:59:47 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35313, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-04-01', Defciency_Descp: 'Port windlass brake cylinder top cover seal slightly leaking', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-01', Target_Date: '2019-04-02', Action_Taken: 'Scraper ring, wear ring and rod seal renewed for top cover and tested - working satisfactory.', unique_id: '25/10/2019 9:01:57 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35317, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-04-16', Defciency_Descp: 'Pump Room Blower Motor Low Insulation.', PO_Ref: '', VIQ_Question_ID: 8498, VIQ_QuestionNo: '10.38', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-24', Target_Date: '2019-04-28', Action_Taken: 'Pump Room fan motor inside the terminal box one wire connection to motor winding got grounded, same replaced with new wire and motor both bearing changed with new spare, blower is operational', unique_id: '25/10/2019 9:03:51 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35322, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-04-28', Defciency_Descp: 'Forward whistle horn , reported not working', PO_Ref: '', VIQ_Question_ID: null, VIQ_QuestionNo: null, Risk_Value: '', Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-04-29', Target_Date: '2019-04-29', Action_Taken: 'Motor electrical connection disconnected to facilitate the repair work of the whistle. Complete unit removed from its place and taken to workshop. Dismantled the unit and found connecting rod bearing completely damaged. Same replaced with old', unique_id: '25/10/2019 9:07:39 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35327, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-01', Defciency_Descp: 'CONNING DISPLAY ,PROCESSOR FAN FAIL', PO_Ref: 'STAI190081', VIQ_Question_ID: 8420, VIQ_QuestionNo: '11.1', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-21', Target_Date: '2019-08-01', Action_Taken: 'processor fan replaced by CODAR technician at Singapore', unique_id: '25/10/2019 9:09:58 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35331, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler F.O. pump supply Mechanical seal leaking', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-31', Action_Taken: 'Mechanical Seal changed , P/P tried out satisfactory', unique_id: '25/10/2019 8:16:31 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35336, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Frequency controllers for MSW pumps #3 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-08-30', Action_Taken: 'FREQUENCY CONTROLLER FOR NO1 AND 2 ATTENDED ON 15/06/2019 AND NOW WORKING SATISFACTORY, As per office instructions Frequency controller not to be changed. Pump to', unique_id: '25/10/2019 11:38:10 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35340, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'VACUUMARATOR PUMP NO.1 END PLATE BADLY WORN OUT .', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-07', Target_Date: '2019-08-25', Action_Taken: 'Pump working satisfactory. Parts kept as spare. To be changed if issue arises', unique_id: '25/10/2019 11:41:49 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35344, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'IGS ECR Main control valve leaking when IG is venting to atmosphere and main blower in use', PO_Ref: 'STAI 190078', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-05', Target_Date: '2019-08-30', Action_Taken: 'Valve seat renewed. Tried out . No leakage observed', unique_id: '25/10/2019 11:45:20 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35348, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'GE fuel line Pr regulating v/v 9k leaking', PO_Ref: 'STAI190112', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-20', Target_Date: '2019-10-31', Action_Taken: 'Confirmed the operation during LSMGO and HFO. Found not leaking. Holdingnow. Under observation. Vessel received spare. Kept standby', unique_id: '25/10/2019 11:48:09 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35352, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-12', Defciency_Descp: 'Control air dryer #1 not working', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-05', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 11:51:49 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35356, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'No 1 boiler burner platform has steam / leakage. Looks like same', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-24', Target_Date: '2019-05-31', Action_Taken: 'steam regulating valve. To be', unique_id: '25/10/2019 11:54:11 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35360, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Air bottles auto drain valve is kept shut. Same to be opened and all the crew to be advised accordingly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-22', Target_Date: '2019-05-28', Action_Taken: 'VALVES OPENED AND CREW ADVISED OF THE OPERATION', unique_id: '25/10/2019 11:56:47 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35364, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Area below the blower in steering Gear room needs to be cleaned.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-03', Target_Date: '2019-07-21', Action_Taken: 'Area cleaned and painted', unique_id: '25/10/2019 12:00:28 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35368, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'In steam line there is steam / water leak from dump bypass valve and air ejector steam inlet valve. To be rectified by closing main steam stop valve', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-07-21', Action_Taken: 'gasket renewed', unique_id: '25/10/2019 1:36:51 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35372, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Provision compressor low pressure gauge to renew', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-02', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:40:19 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35377, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Port side bunker manifold pressure gauge to renew, as same showing wrong indication.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-05-30', Target_Date: '2019-06-21', Action_Taken: 'Pressure Gauge renewed', unique_id: '25/10/2019 1:44:14 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35381, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'All 3 Aft winches gear case relief valve spring is missing. To replace.', PO_Ref: '', VIQ_Question_ID: 8403, VIQ_QuestionNo: '9.14', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-14', Target_Date: '2019-06-21', Action_Taken: 'Springs replaced.', unique_id: '25/10/2019 1:50:47 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35385, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'Stbd side pump room blower motor top cover is temporarily repaired by cold work. New cover to fabricate and fit.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-15', Target_Date: '2019-06-21', Action_Taken: 'Top cover brought in E/R workshop and fabricated', unique_id: '25/10/2019 1:56:01 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35389, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-21', Defciency_Descp: 'T/C air intake room cleaning required.', PO_Ref: '', VIQ_Question_ID: 8489, VIQ_QuestionNo: '10.29', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-20', Target_Date: '2019-07-21', Action_Taken: 'Gratings removed, chipped and painted.', unique_id: '25/10/2019 2:07:01 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35393, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'COPT#2 Oil caution remark from shore analysis', PO_Ref: '', VIQ_Question_ID: 8467, VIQ_QuestionNo: '10.7', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-12', Target_Date: '2019-06-21', Action_Taken: 'COPT NO2 OIL SUMP, DRAINED CLEANED AND OIL RENEWED', unique_id: '25/10/2019 2:09:27 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35397, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-05-25', Defciency_Descp: 'Few buttons on MF/HF keypad not functioning . Also,few pins of flat cable connected to the Keypad PCB found damaged making the above mentioned keys inoperational.', PO_Ref: 'STAI195045', VIQ_Question_ID: 8340, VIQ_QuestionNo: '4.21', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-18', Target_Date: '2019-08-30', Action_Taken: 'MF/HF equipment flat cable renewed and tested the GMDSS found working satisfactory.', unique_id: '25/10/2019 2:12:28 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35402, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Soot blower # 3 of LP side is stuck. Not operating', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-06-29', Target_Date: '2019-06-30', Action_Taken: 'Soot Blower LP3 removed from place , soot blower was stuck badly, sealing air passage was choked completely, same made free and cleared. Soot blower fitted back in place and tried out , satisfactory', unique_id: '25/10/2019 2:15:59 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35406, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 13, Status_ID: 6, Record_Date: '2019-05-27', Defciency_Descp: 'Clutch lining of Vacuum pump of Emergency Fire Pump came off while trying out of the pump', PO_Ref: '', VIQ_Question_ID: 8558, VIQ_QuestionNo: '5.41', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-26', Target_Date: '2019-08-30', Action_Taken: 'Clutch lining renewed with the spare recd , pump tried out, satisfactory', unique_id: '25/10/2019 2:18:03 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35410, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-29', Defciency_Descp: 'Vibscanner is not operational', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received new vibscanner. ', unique_id: '25/10/2019 2:21:26 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35415, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-01', Defciency_Descp: 'Siren for wind Hi-Hi alarm not operational and only light is working.', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-02', Target_Date: '2019-10-31', Action_Taken: 'Spares received at Singapore on 31/08/2019. Wind Hi-Hi siren and light replaced. Working satsifactorily', unique_id: '25/10/2019 2:25:15 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35419, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'The GMT time in the BilgeGuard is 11-12 minutes behind the actual GMT time', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-30', Action_Taken: 'CHANGED 15 PPM MONITOR. NOW DIFFERENCE IS 3 MINS', unique_id: '25/10/2019 2:29:07 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35423, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-06-11', Defciency_Descp: 'One of the Personal Gas Meter MSA Altair 4X (Sr no. 06028737) Showing Error message on O2, CO & H2S sensor on starting the equipment', PO_Ref: '', VIQ_Question_ID: 8540, VIQ_QuestionNo: '5.23', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-09', Target_Date: '2019-08-30', Action_Taken: 'Replaced with the new gas meter received under warranty at GOLA, US on 09th July 2019', unique_id: '25/10/2019 2:32:38 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35428, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'The WBT gas detection system function giving Fault 19 and 17. and is inoperable. FAULT (19) - “No custom setup, using default setup” comes and later after 15-20 seconds the FAULT(17) – “Analyzing unit no answer” shows.', PO_Ref: '', VIQ_Question_ID: 8539, VIQ_QuestionNo: '5.22', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-07-08', Target_Date: '2019-08-30', Action_Taken: 'Makers technician attanded vessel at GOLA, US on 08th July 2019. Troubleshooting done, necessary spares changed by technician and reconfiguration done.', unique_id: '25/10/2019 2:37:17 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35432, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-12', Defciency_Descp: 'UTI (Sr. No. G17710) showing error message on start up indicating ‘’No msg’’.', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Tape was unwinded to check for any damage and found tape damage at 60cm mark. Continuity test was done for the UTI to confirm the tape error.As per message from office as vessel have total 4 UTIs, so this faulty UTI to be landed ashore at next', unique_id: '25/10/2019 2:40:16 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35437, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-06-16', Defciency_Descp: 'WBT 1 (P) gauge showing erratic reading', PO_Ref: '', VIQ_Question_ID: 8576, VIQ_QuestionNo: '8.8', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-02', Target_Date: '2019-10-31', Action_Taken: 'Renewed sensor on 02nd Oct 2019.', unique_id: '25/10/2019 2:42:33 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35441, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-21', Defciency_Descp: 'The local touch panel of WHRS( EGB) does not operate with touch, however operational with mouse', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-20', Target_Date: '2019-11-30', Action_Taken: 'The touch screen panel renewed', unique_id: '25/10/2019 2:47:46 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35445, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-24', Defciency_Descp: 'HFO PFR P/P NO2 MAGNETIC COUPLING CASING HOLED', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-10', Target_Date: '2019-10-31', Action_Taken: 'CHANGED CAN OF THE COUPLING', unique_id: '25/10/2019 2:56:36 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35449, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-29', Defciency_Descp: 'KW not matching with KWh meter reading and which leads to high SFOC, diff in % utilization of AEs.Actually KWHR is not for present KW', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-15', Target_Date: '2019-10-31', Action_Taken: 'RESET THE KWH METER. NOW SHOWING VALUES CORRECTLY', unique_id: '25/10/2019 2:59:03 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35453, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-06', Defciency_Descp: 'M/E F.O. leak off alarm not coming in the AMS', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-10', Target_Date: '2019-09-30', Action_Taken: 'Changed the Net DI 16. found alarm stilll there. Then found that in the tag in the AMS the switch had shifted to Man. Changed back to Auto. It is working fine. Changed it back to old NET DI16. Still it is functional.', unique_id: '25/10/2019 3:06:56 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35457, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-12', Defciency_Descp: 'EGB exhasut gas outlet temperature probe giving wrong readings', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-15', Target_Date: '2019-09-30', Action_Taken: 'needs replacement. Shall raise RO for same. Entered in DD defect list', unique_id: '25/10/2019 3:13:00 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35461, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'UTI (Sr. No. G18578) Display becomes blurred everytime after 5-10 minutes of operation', PO_Ref: '', VIQ_Question_ID: 8580, VIQ_QuestionNo: '8.12', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-03', Target_Date: '2019-10-31', Action_Taken: 'Interchanged with the Display unit of UTI G17710 which was to be landed ashore as per message from office. Now UTI G 18578 is in good working order', unique_id: '25/10/2019 3:24:54 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35465, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-23', Defciency_Descp: 'Work shop AC OCR under rated ,getting tripped', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-09', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:35:14 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35469, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'STBD life boat control circuit switch damaged', PO_Ref: '', VIQ_Question_ID: 8546, VIQ_QuestionNo: '5.29', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-03', Target_Date: '2019-10-15', Action_Taken: 'Requisition received at Singapore on 31/08/2019. Control circuit replaced. Working satisfactorily now.', unique_id: '25/10/2019 3:37:27 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35473, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-07-24', Defciency_Descp: 'Two wire programmable TX defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-09-26', Target_Date: '2019-10-30', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:42:18 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35477, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-25', Defciency_Descp: 'Scrubber p/p mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-08', Target_Date: '2019-08-15', Action_Taken: 'Mechanical sal renewed. Pump tried out.', unique_id: '25/10/2019 3:48:02 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35481, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-08-08', Defciency_Descp: 'Cover for General Alarm switch on Port/Stbd boat deck broken', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-11', Target_Date: '2019-10-31', Action_Taken: 'Spares received and changed. Found working satisfactory.', unique_id: '25/10/2019 3:50:01 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35485, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-11', Defciency_Descp: 'The battery for BilgeMon 488 for OWS showing voltage 0.330 V against the required value of 2.5', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-12', Target_Date: '2019-10-31', Action_Taken: 'CHANGED 15 PPM SENSOR WITH NEW', unique_id: '25/10/2019 3:52:18 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35490, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-08-16', Defciency_Descp: 'Fire and GS p/p 1 mech seal leaking', PO_Ref: '', VIQ_Question_ID: 8491, VIQ_QuestionNo: '10.31', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-23', Target_Date: '2019-08-30', Action_Taken: 'Pump dismantled and overhauled, mech seal and bottom line brearing renewed', unique_id: '25/10/2019 3:57:52 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35494, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-07-18', Defciency_Descp: 'Stbd windlass Hydraulic brake Cylinder leaking from Cylinder top seal during anchoring operations', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-08-26', Target_Date: '2019-08-30', Action_Taken: 'Road seal and scrapper ring renewed. Brake tried out and found satisfactory. No further leaks observed.', unique_id: '25/10/2019 4:23:34 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35499, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-07-20', Defciency_Descp: 'IG 43 - deck isolation valave for the IG Line after the IG NRV was found to be leaking and not holding', PO_Ref: 'STAI190182', VIQ_Question_ID: 8593, VIQ_QuestionNo: '8.25', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-25', Target_Date: '2019-10-30', Action_Taken: 'IG 43 valve removed from location and found valve disc damaged. Valve disc was builded and put back in plce again. But still minor leak exist. RO raised for Valve disc and seat ring. Valve renewed.', unique_id: '25/10/2019 4:26:54 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35503, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-05-10', Defciency_Descp: 'Aux Boiler Feed water pumps motor #1 and #3 cooling Fan damaged', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-30', Action_Taken: 'Received the spare and changed the cooling fan. ', unique_id: '25/10/2019 12:03:13 AM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35508, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-06-20', Defciency_Descp: 'Kyma Engine Analyser defective', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-10-31', Target_Date: '2019-11-30', Action_Taken: 'Changed the cable connecting to computer by Technician', unique_id: '25/10/2019 2:44:53 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35512, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-04', Defciency_Descp: 'Anemometer- Wind speed transmitter found not working', PO_Ref: '', VIQ_Question_ID: 8326, VIQ_QuestionNo: '4.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-13', Target_Date: '2019-01-14', Action_Taken: 'Old repaired Anemometer transmitter installed. Tested and found operational.', unique_id: '24/10/2019 9:47:45 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35516, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 5, Status_ID: 6, Record_Date: '2019-01-11', Defciency_Descp: 'FWD air horn non operational', PO_Ref: '', VIQ_Question_ID: 8497, VIQ_QuestionNo: '10.37', Risk_Value: 2, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Air horn compressor and motor overhauled , fitted back and tried out, working satisfactory.', unique_id: '24/10/2019 9:52:15 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35520, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'IG Fan drain line in 3rd deck platform found leaking due to crack in the pipeline.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-12', Target_Date: '2019-01-12', Action_Taken: 'New pipe fabricated wid stainless steel pipe and flange . Pipe replaced with fabricated one and tested, found satisfactory.', unique_id: '24/10/2019 9:57:34 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35524, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-12', Defciency_Descp: 'Main engine unit no.4 cyl.jacket inlet pipe leaking from flange joint.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-16', Target_Date: '2019-01-16', Action_Taken: 'Gasket replaced and boxed back with stainless steel bolts.', unique_id: '24/10/2019 9:59:53 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35528, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 15, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-14', Defciency_Descp: 'Hydraulic oil leakage from FWD windlass (PORT) High/Low control lever (DIRECTIONAL CONTROL VALVE)', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-18', Target_Date: '2019-01-18', Action_Taken: 'Both seals and o rings changed for the Directional control valve andf tested, and found working satisfactory.', unique_id: '24/10/2019 10:02:27 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35532, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'COPT # 2 Discharge line flange valve no.260 in pump room found traces of oil leakage.', PO_Ref: '', VIQ_Question_ID: 8615, VIQ_QuestionNo: '8.44', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-31', Target_Date: '2019-04-28', Action_Taken: 'Oil traces cleaned and flange tightened,no oil leakage', unique_id: '24/10/2019 10:06:01 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35536, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Stenciling of various remote sounding boxes for ballast tanks missing', PO_Ref: '', VIQ_Question_ID: 8426, VIQ_QuestionNo: '11.7', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-04-28', Action_Taken: 'Steciling carried out for all remote sounding boxes for ballast tanks', unique_id: '24/10/2019 10:11:45 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35540, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'One light in pump room 2nd deck not working.', PO_Ref: '', VIQ_Question_ID: 8430, VIQ_QuestionNo: '11.11', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-01-29', Target_Date: '2019-01-28', Action_Taken: 'Light renewed', unique_id: '24/10/2019 10:14:28 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35544, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 11, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Pressure regulator in air line for sea chest testing not fitted', PO_Ref: '', VIQ_Question_ID: 8351, VIQ_QuestionNo: '6.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-12', Target_Date: '2019-04-28', Action_Taken: 'Pressure regulator fitted in air line for sea chest testing.', unique_id: '24/10/2019 10:17:16 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35548, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 6, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 12, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Windlass pinion bearing found not greased and grease point not clearly marked.', PO_Ref: '', VIQ_Question_ID: 8391, VIQ_QuestionNo: '9.2', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-06', Target_Date: '2019-04-28', Action_Taken: 'Windlass pinion bearing greasing carried out and grease point marked.', unique_id: '24/10/2019 10:19:29 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 6, insertId: 35553, serverStatus: 2, warningCount: 3, message: '&Records: 6 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 8, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'Helicopter equipement CO2 extinguishers not as per requirement', PO_Ref: '', VIQ_Question_ID: 8520, VIQ_QuestionNo: '5.4', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-11', Target_Date: '2019-04-28', Action_Taken: 'CO2 extinguishers installed as per requirement.', unique_id: '24/10/2019 10:24:15 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35559, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'ME UNIT # 3 Starting air valve solenoid cable was reported damaged, junction box found open and new cable laid externally, cable to be routed properly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-03', Target_Date: '2019-04-28', Action_Taken: 'Cable renewed soon after receiving new cable.', unique_id: '24/10/2019 10:26:52 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35564, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 5, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-01-28', Defciency_Descp: 'EGB bellow between LP and HP evaporator had traces of leakage, to be checked , cleaned and painted.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-02-17', Target_Date: '2019-04-28', Action_Taken: 'Bellow inspected, no leakes found.Bellow area cleaned and painted.', unique_id: '24/10/2019 10:29:52 PM' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 5, insertId: 35569, serverStatus: 2, warningCount: 3, message: '&Records: 5 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 15, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler outside ECR not operational. Cooler Compressor not running.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-09', Target_Date: '2019-11-15', Action_Taken: 'Leak rectified and cooler put in use', unique_id: '2019-08-11 19:41:53.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35574, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'T/C suction room door not easy to open. To ease up and grease.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-06', Target_Date: '2019-11-08', Action_Taken: 'DOOR EASED UP. ', unique_id: '2019-11-08 19:58:10.999' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35578, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Steering gear room door self-closing mechanism needs to adjust as door remains in open condition.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-07', Target_Date: '2019-11-07', Action_Taken: 'Door adjusted. ', unique_id: '2019-11-08 20:07:39.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35582, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Chlorine dosing pump of STP was running but no liquid passing. To be purged and checked regularly.', PO_Ref: '', VIQ_Question_ID: 8492, VIQ_QuestionNo: '10.32', Risk_Value: 4, Audit_Type: 1, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-05', Target_Date: '2019-11-05', Action_Taken: 'Checked and purged. ', unique_id: '2019-08-11 20:09:57.000' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35586, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 16, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Drain near both aft E/R blower are choked. To be cleared.', PO_Ref: '', VIQ_Question_ID: 8349, VIQ_QuestionNo: '6.2', Risk_Value: 3, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-13', Target_Date: '2019-12-05', Action_Taken: 'Drain line opened up for both blowers and cleared. ', unique_id: 'Fri Nov 08 2019 10:42:57 GMT+0000 (Coordinated Universal Time)' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35590, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 4, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Water cooler in officer mess room was kept in isolated condition due to leak. TO be made operational.', PO_Ref: '', VIQ_Question_ID: 8432, VIQ_QuestionNo: '11.13', Risk_Value: 1, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-14', Target_Date: '2019-11-19', Action_Taken: 'Fountain tap leak was rectified. System back in operation. ', unique_id: 'Sun Aug 11 2019 09:43:02 GMT+0000 (Coordinated Universal Time)' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35594, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- deleteRes OkPacket { fieldCount: 0, affectedRows: 4, insertId: 0, serverStatus: 34, warningCount: 0, message: '', protocol41: true, changedRows: 0 } { Inspection_Type_ID: 13, PSC_Ref_ID: null, PSC_MOU_ID: null, Area_Observation_ID: 14, Status_ID: 6, Record_Date: '2019-11-05', Defciency_Descp: 'Both boiler gauge glass light not working.', PO_Ref: '-', VIQ_Question_ID: 8492, VIQ_QuestionNo: 10.32, Risk_Value: 4, Audit_Type: 0, Critical_Item_Flag: 'No', Info_Sharing_Flag: 'No', DryDock_Flag: 0, Completion_Date: '2019-11-15', Target_Date: '2019-11-15', Action_Taken: 'Light changed. ', unique_id: 'Fri Nov 08 2019 19:44:49 GMT+0000 (Coordinated Universal Time)' } special res [ OkPacket { fieldCount: 0, affectedRows: 1, insertId: 0, serverStatus: 2, warningCount: 2, message: '(Rows matched: 1 Changed: 1 Warnings: 2', protocol41: true, changedRows: 1 }, OkPacket { fieldCount: 0, affectedRows: 4, insertId: 35598, serverStatus: 2, warningCount: 3, message: '&Records: 4 Duplicates: 0 Warnings: 3', protocol41: true, changedRows: 0 } ] incr :- incr :- incr :- 48 { C_Type: '', InfoSharing_Flag: 'false', InfoSharing_Flag_Change: 'false', Ship_ID: '48', Record_Date: 'null', Inspection_Type_ID: 'null', Deficiency_Type_ID: 'null', Defciency_Descp: 'null', Deficiency_Cause: 'null', Equipments: 'null', Action_Taken: 'null', Target_Date: 'null', Completion_Date: 'null', Superident_Remarks: 'null', Status_ID: 'null', PSCRefNumbers: 'null', AreaObservation: 'null', Risk_Value: 'null', PSC_Ref_ID: 'null', Area_Observation_ID: 'null', Observeration_code: 'null', DryDock_Flag: 'false', Critical_Item_Flag: 'false', Complete_Flag: '0', currentPage: '0', itemsPerPage: '20' } 48 { C_Type: '', InfoSharing_Flag: 'false', InfoSharing_Flag_Change: 'false', Ship_ID: '48', Record_Date: 'null', Inspection_Type_ID: 'null', Deficiency_Type_ID: 'null', Defciency_Descp: 'null', Deficiency_Cause: 'null', Equipments: 'null', Action_Taken: 'null', Target_Date: 'null', Completion_Date: 'null', Superident_Remarks: 'null', Status_ID: 'null', PSCRefNumbers: 'null', AreaObservation: 'null', Risk_Value: 'null', PSC_Ref_ID: 'null', Area_Observation_ID: 'null', Observeration_code: 'null', DryDock_Flag: 'false', Critical_Item_Flag: 'false', Complete_Flag: '1', currentPage: '0', itemsPerPage: '20' }